Ion Chromatography Coupled with Mass Spectrometry for Metabolomics
Applications | 2011 | Thermo Fisher ScientificInstrumentation
Ion chromatography coupled with mass spectrometry (IC-MS) provides a robust platform for the separation and detection of small ionic and highly polar metabolites that are poorly retained or resolved by traditional reversed-phase LC methods. By integrating on-line eluent suppression and desalting, IC-MS enables high-resolution mass analysis of organic acids, carbohydrates, nucleotides, amino acids, and other charged biomolecules, expanding coverage of the metabolome in diverse biological matrices.
The article presents an overview of modern IC-MS systems, focusing on the development of continuous electrolytic KOH gradients, suppressor technologies for direct MS compatibility, and the application of these methods to metabolomics and metabonomics studies. It reviews key separation chemistries, detection techniques, and bioinformatic tools used for metabolite identification and pathway analysis.
The described IC-MS setup employs:
These components enable direct coupling of IC separations to MS without offline desalting.
IC-MS successfully resolves a broad range of metabolic intermediates, including carboxylated, phosphorylated, sulfonated species, sugars, biogenic amines, and nucleotides. Comparative studies demonstrate that combining IC with reversed-phase and HILIC modes significantly increases metabolome coverage. In Trypanosoma brucei extracts, IC-MS uniquely identified 24 of 80 tryptophan pathway intermediates and expanded detection across glycolytic and amino acid biosynthetic pathways. Advanced data processing tools (XCMS, MZmine, SIEVE, MassTRIX, MetExplore) and databases (HMDB, KEGG, ChemSpider) support label-free quantification and pathway mapping.
Emerging directions include:
Continuous on-line suppressed IC-MS represents a powerful addition to the metabolomics toolkit, addressing critical gaps in the analysis of polar and ionic metabolites. By combining efficient separation, desalting, and high-resolution MS detection, IC-MS enhances metabolome coverage and supports comprehensive pathway elucidation across biological systems.
IC-MS
IndustriesMetabolomics
ManufacturerThermo Fisher Scientific
Summary
Significance of the topic
Ion chromatography coupled with mass spectrometry (IC-MS) provides a robust platform for the separation and detection of small ionic and highly polar metabolites that are poorly retained or resolved by traditional reversed-phase LC methods. By integrating on-line eluent suppression and desalting, IC-MS enables high-resolution mass analysis of organic acids, carbohydrates, nucleotides, amino acids, and other charged biomolecules, expanding coverage of the metabolome in diverse biological matrices.
Aims and study overview
The article presents an overview of modern IC-MS systems, focusing on the development of continuous electrolytic KOH gradients, suppressor technologies for direct MS compatibility, and the application of these methods to metabolomics and metabonomics studies. It reviews key separation chemistries, detection techniques, and bioinformatic tools used for metabolite identification and pathway analysis.
Methodology and instrumentation
The described IC-MS setup employs:
- An eluent generator producing high-purity KOH gradients at the column head
- A high-efficiency 2 mm i.d. anion-exchange column
- A continuous low-dead-volume electrolytic suppressor converting KOH eluents to pure water
- Conductivity monitoring to ensure eluent purity below 1 μS/cm
- Electrospray ionization high-resolution mass spectrometer for detection
- Optional organic solvent makeup flow to enhance desolvation
These components enable direct coupling of IC separations to MS without offline desalting.
Main findings and discussion
IC-MS successfully resolves a broad range of metabolic intermediates, including carboxylated, phosphorylated, sulfonated species, sugars, biogenic amines, and nucleotides. Comparative studies demonstrate that combining IC with reversed-phase and HILIC modes significantly increases metabolome coverage. In Trypanosoma brucei extracts, IC-MS uniquely identified 24 of 80 tryptophan pathway intermediates and expanded detection across glycolytic and amino acid biosynthetic pathways. Advanced data processing tools (XCMS, MZmine, SIEVE, MassTRIX, MetExplore) and databases (HMDB, KEGG, ChemSpider) support label-free quantification and pathway mapping.
Benefits and practical applications
- Enhanced separation and sensitivity for ionic metabolites
- Expanded metabolite coverage in clinical, environmental, and food analyses
- Improved identification confidence through orthogonal retention and accurate mass data
- Streamlined workflows for biomarker discovery and metabolic phenotyping
Future trends and potential applications
Emerging directions include:
- Integration of cation-exchange IC-MS for amine profiling
- Capillary IC formats for micro-scale, high-sensitivity analyses
- Deeper coupling with systems biology tools to link proteomic changes to metabolic responses
- Automation of gradient generation and data interpretation for high-throughput metabolomics
Conclusion
Continuous on-line suppressed IC-MS represents a powerful addition to the metabolomics toolkit, addressing critical gaps in the analysis of polar and ionic metabolites. By combining efficient separation, desalting, and high-resolution MS detection, IC-MS enhances metabolome coverage and supports comprehensive pathway elucidation across biological systems.
References
- Small H., Stevens T.S., Bauman W.C. Anal. Chem. 1975, 47, 1801
- DeBorba B., Rohrer J.S. J. Chromatogr. A 2007, 1155, 22–30
- Lyubarskaya Y. et al. Anal. Biochem. 2006, 348, 24–39
- Thayer J.R. et al. Anal. Biochem. 2007, 361, 132–139
- Weiss J. Ion Chromatography; VCH Weinheim, 1995
- Wang L.J., Schunte W.A. LC-GC, 2009
- Mohsin S.B. J. Chromatogr. A 2000, 884, 23–30
- Bauer K.H. et al. J. Chromatogr. A 1999, 837, 117–128
- Bruggink C. et al. J. Chromatogr. A 2005, 1085, 104–109
- Saccani G. et al. J. Chromatogr. A 2005, 1082, 43–50
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Ion Chromatography Coupled with Mass Spectrometry for Metabolomics
2011|Thermo Fisher Scientific|Technical notes
Ion Chromatography Coupled with Mass Spectrometry for Metabolomics CAN 108 Karl Burgess Functional Genomics, Joesef Black building, Glasgow University, Glasgow, UK Introduction The fields of metabolomics and metabonomics attempt to phenotype and quantify the vast array of metabolites present in…
Key words
exchange, exchangemetabolites, metabolitesmetabolomics, metabolomicspathways, pathwayseluent, eluention, ionbiological, biologicalsuppressor, suppressormetabolic, metabolicseparation, separationintermediates, intermediatesmetabonomics, metabonomicssuppression, suppressiondesalting, desaltingcoverage
Untargeted Metabolic Profiling of Oral Cancer Cells Using Capillary Ion Chromatography Coupled with an Orbitrap Mass Spectrometer
2016|Thermo Fisher Scientific|Applications
Terri Christison1 and Junhua Wang2 Thermo Fisher Scientific, Sunnyvale, CA 2 Thermo Fisher Scientific, San Jose, CA 1 Appli cat i on N ote 1 1 3 7 Untargeted Metabolic Profiling of Oral Cancer Cells Using Capillary Ion Chromatography Coupled…
Key words
capillary, capillarycancer, canceroral, oralmetabolites, metaboliteshram, hramwere, wereneck, neckmetabolite, metaboliteaconitate, aconitateexactive, exactiveeluent, eluentmass, massmonophosphate, monophosphateuhplc, uhplchilic
Targeted metabolomics method using IC Orbitrap with high resolution mass spectrometry
2020|Thermo Fisher Scientific|Applications
CUSTOMER APPLICATION NOTE 73265 Targeted metabolomics method using IC Orbitrap with high resolution mass spectrometry Authors: Yoshihiro Izumi, Takeshi Bamba, Medical Institute of Bioregulation, Kyushu University, Research Center for Transomics Medicine, Division of Metabolomics Keywords: Anionic compound, samplepretreatment, ion chromatography,…
Key words
exactive, exactivemetabolites, metabolitesnegative, negativeion, ionsuppressor, suppressorapproach, approachpotassium, potassiummeasurement, measurementsystem, systemphosphate, phosphatecamp, campmass, masseluent, eluentpolar, polarabundance
Pathway-Targeted Metabolomic Analysis in Oral/Head and Neck Cancer Cells Using Ion Chromatography-Mass Spectrometry
2016|Thermo Fisher Scientific|Applications
Junhua Wang1, Terri Christison1, Krista Backiel2, Grace Ji3, Shen Hu3, Linda Lopez1, Yingying Huang1, Andreas Huhmer1. 1Thermo Fisher Scientific Inc., San Jose, CA; 2Cambridge Isotope Laboratories Inc., Tewksbury, MA; 3 School of Dentistry and Jonsson Comprehensive Cancer Center, UCLA, Los…
Key words
tca, tcatargeted, targetedcancer, cancermetabolites, metabolitesendogenous, endogenouscells, cellsisotope, isotopemetabolomics, metabolomicsnontargeted, nontargetedstable, stablecycle, cyclestandards, standardspyruvate, pyruvatecapic, capicmetabolic