Ion Pac CS5A Column & MetPac Reagents
Technical notes | 2001 | Thermo Fisher ScientificInstrumentation
The accurate measurement of transition and lanthanide metals is essential for environmental monitoring geological research industrial quality control and pharmaceutical analysis. Ion exchange chromatography offers selective separation of metal ions enabling rapid routine assays with high sensitivity and reproducibility.
This study presents a comprehensive workflow centered on the IonPac CS5A cation exchange column paired with MetPac ready to dilute reagents. The goal is to demonstrate simultaneous separation of common transition metals in under eleven minutes to achieve low detection limits direct injection of acidic matrices and flexible method adaptation for lanthanide analysis.
The IonPac CS5A analytical column employs a high crosslinked pellicular resin for robust separations. Two eluent systems are described: pyridine dicarboxylic acid (PDCA) for optimal separation of iron II and III copper nickel zinc cobalt cadmium and manganese and an oxalic acid diglycolic acid gradient for lanthanides and mixed mode transition metal separation. Postcolumn complexation with 4 2 pyridylazo resorcinol and ultraviolet absorbance detection at 520–530 nm ensures sensitive quantification. Acidic digests can be injected directly without pH adjustment while microbore 2 mm formats three to fourfold reduce reagent consumption and enhance mass sensitivity.
Using the PDCA eluent common transition metals resolved in less than eleven minutes with detection limits down to 10 µg/L. Oxalate eluent achieved baseline separation of lead copper cadmium cobalt zinc and nickel. Lanthanides were separated with a gradient of oxalic acid/diglycolic acid and detected at 520 nm. Direct injection of phosphoric acid digests yielded reliable quantification of iron nickel and zinc at sub-100 µg/L levels. Chevron style preconcentration via MetPac CC-1 and TMC-1 lowered detection limits to the low ng/L and sub-ng/L range.
Integration of ion chromatography with mass spectrometry could extend detection capabilities for complex matrices. Advances in resin chemistry may further improve selectivity for emerging contaminants. Automation of sample pretreatment chelation concentration and postcolumn delivery will enhance lab productivity. Development of new complexing reagents may broaden the range of metal analytes accessible by this approach.
The IonPac CS5A column together with MetPac reagents provides a robust reliable and flexible platform for routine analysis of transition and lanthanide metals. Its rapid separations low detection limits direct sample injection and microbore options deliver significant advantages for diverse analytical laboratories.
Consumables, LC columns
IndustriesManufacturerThermo Fisher Scientific
Summary
Importance of the Topic
The accurate measurement of transition and lanthanide metals is essential for environmental monitoring geological research industrial quality control and pharmaceutical analysis. Ion exchange chromatography offers selective separation of metal ions enabling rapid routine assays with high sensitivity and reproducibility.
Objectives and Overview
This study presents a comprehensive workflow centered on the IonPac CS5A cation exchange column paired with MetPac ready to dilute reagents. The goal is to demonstrate simultaneous separation of common transition metals in under eleven minutes to achieve low detection limits direct injection of acidic matrices and flexible method adaptation for lanthanide analysis.
Methodology and Instrumentation
The IonPac CS5A analytical column employs a high crosslinked pellicular resin for robust separations. Two eluent systems are described: pyridine dicarboxylic acid (PDCA) for optimal separation of iron II and III copper nickel zinc cobalt cadmium and manganese and an oxalic acid diglycolic acid gradient for lanthanides and mixed mode transition metal separation. Postcolumn complexation with 4 2 pyridylazo resorcinol and ultraviolet absorbance detection at 520–530 nm ensures sensitive quantification. Acidic digests can be injected directly without pH adjustment while microbore 2 mm formats three to fourfold reduce reagent consumption and enhance mass sensitivity.
Instrumentation Used
- IonPac CS5A analytical columns 4×250 mm and 2×250 mm with CG5A guard columns
- MetPac PDCA and Oxalic Acid ready to dilute eluent concentrates
- PC10 postcolumn pneumatic delivery system with knitted reaction coil and mixing tee
- AD20 absorbance detector operating at 530 nm
- MetPac CC-1 chelation concentration column and TMC-1 concentrator for trace level enrichment
Key Results and Discussion
Using the PDCA eluent common transition metals resolved in less than eleven minutes with detection limits down to 10 µg/L. Oxalate eluent achieved baseline separation of lead copper cadmium cobalt zinc and nickel. Lanthanides were separated with a gradient of oxalic acid/diglycolic acid and detected at 520 nm. Direct injection of phosphoric acid digests yielded reliable quantification of iron nickel and zinc at sub-100 µg/L levels. Chevron style preconcentration via MetPac CC-1 and TMC-1 lowered detection limits to the low ng/L and sub-ng/L range.
Benefits and Practical Applications
- Complete turnkey solution for transition and lanthanide metal analysis
- Fast cycle times under eleven minutes for high sample throughput
- Low detection limits in ppb and ppt range for trace monitoring
- Direct injection of acidic and high ionic strength matrices without neutralization
- Reduced eluent and reagent usage with microbore formats
Future Trends and Opportunities
Integration of ion chromatography with mass spectrometry could extend detection capabilities for complex matrices. Advances in resin chemistry may further improve selectivity for emerging contaminants. Automation of sample pretreatment chelation concentration and postcolumn delivery will enhance lab productivity. Development of new complexing reagents may broaden the range of metal analytes accessible by this approach.
Conclusion
The IonPac CS5A column together with MetPac reagents provides a robust reliable and flexible platform for routine analysis of transition and lanthanide metals. Its rapid separations low detection limits direct sample injection and microbore options deliver significant advantages for diverse analytical laboratories.
References
- Technical Note 27 Determination of Lanthanide Metals in Digested Rock Samples by Chelation Ion Chromatography
- Technical Note 28 Ion Chromatography Inductively Coupled Argon Plasma A New Technique for Trace Metal Determinations
- Technical Note 29 Automated Sample Preconcentration of Metals in Drinking Water for Inductively Coupled Argon Plasma Spectroscopy
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Determination of Transition Metals in Serum and Whole Blood by Ion Chromatography
2001|Thermo Fisher Scientific|Applications
Application Note 108 Determination of Transition Metals in Serum and Whole Blood by Ion Chromatography INTRODUCTION The determination of transition metals in physiological fluids is of considerable interest in clinical chemistry. In recent years several studies have linked the concentrations…
Key words
metpac, metpacmetals, metalspostcolumn, postcolumneluent, eluenttransition, transitionpdca, pdcaoxalic, oxalicwhole, wholeserum, serumreagent, reagentblood, bloodacid, acidphysiological, physiologicalzinc, zincdiluent
Determination of Transition Metals by Ion Chromatography
|Thermo Fisher Scientific|Applications
Technical Note 10 Determination of Transition Metals by Ion Chromatography INTRODUCTION Metal ions can exist in several different forms. The factors which determine the form of the metal ion are the extent of complexation and the oxidation state. In many…
Key words
metals, metalschelating, chelatingcomplexed, complexedmetpac, metpacpdca, pdcatransition, transitionhydrated, hydratedagents, agentsoxalic, oxalicligands, ligandsweakly, weaklypostcolumn, postcolumncomplexes, complexeseluent, eluentanionic
Determination of transition metals by ion chromatography
2017|Thermo Fisher Scientific|Technical notes
TECHNICAL NOTE 10 Determination of transition metals by ion chromatography Keywords Introduction Ion chromatography, IC, Dionex ICS-5000+, Dionex IonPac CS5A Metal ions can exist in several different forms. The factors that determine the form of the metal ion are the…
Key words
metals, metalschelating, chelatingmetpac, metpachydrated, hydrateddionex, dionexpostcolumn, postcolumncomplexed, complexedpdca, pdcaanionic, anioniceluent, eluentagents, agentsweakly, weaklypar, partransition, transitioncomplexes
Determination of Transition Metals at PPT Levels in High-Purity Water and SC2 (D-clean) Baths
1998|Thermo Fisher Scientific|Applications
Application Note 131 Determination of Transition Metals at PPT Levels in High-Purity Water and SC2 (D-clean) Baths INTRODUCTION EQUIPMENT Metal atoms and conductive particle contaminants are undesirable and potentially damaging in semiconductor manufacturing processes. Oxidative cleaning baths and large volumes…
Key words
pdca, pdcametals, metalstransition, transitiondqp, dqppar, parppt, pptpostcolumn, postcolumnlevels, levelsminutes, minutesleachable, leachabledionex, dionexpump, pumptubing, tubingeluent, eluentconcentrator