Thermo UltiMate 3000 Series Rapid Separation Pumps
Brochures and specifications | 2010 | Thermo Fisher ScientificInstrumentation
The demand for ultrahigh‐speed and ultrahigh‐resolution liquid chromatography has grown rapidly in pharmaceutical, environmental and forensic laboratories. Efficient separations with reproducible retention times, high pressure capabilities and minimized gradient delay are key for accelerating method development, increasing sample throughput and ensuring data quality in routine analysis.
This document presents the design features, performance metrics and application potential of the UltiMate 3000 Series Rapid Separation Pump family. The goal is to demonstrate how binary, quaternary and dual‐gradient pump systems deliver unmatched flow‐pressure footprints, advanced mixing technologies and flexible solvent handling to support a wide range of HPLC and UHPLC workflows.
The UltiMate 3000 Series includes four models of Rapid Separation Pumps:
Key engineering features:
Performance evaluations highlighted:
These pump systems offer clear advantages for pharmaceutical quality control, environmental testing, forensic analyses and LC–MS workflows:
Emerging directions include integration of dual‐gradient pumps into multidimensional LC configurations, expanded automation for real‐time instrument health monitoring, advanced software-driven method translation between HPLC and UHPLC, and scale-up potential for preparative separations using similar high‐pressure platforms.
The UltiMate 3000 Series Rapid Separation Pumps set a new standard in chromatographic performance by combining high pressure tolerance, precise flow control and advanced mixing technologies. Their versatility and reliability make them an essential tool for modern analytical laboratories seeking to maximize speed, resolution and operational efficiency.
No specific references were provided in the source document.
HPLC
IndustriesManufacturerThermo Fisher Scientific
Summary
Significance of the Topic
The demand for ultrahigh‐speed and ultrahigh‐resolution liquid chromatography has grown rapidly in pharmaceutical, environmental and forensic laboratories. Efficient separations with reproducible retention times, high pressure capabilities and minimized gradient delay are key for accelerating method development, increasing sample throughput and ensuring data quality in routine analysis.
Objectives and Overview of the Study
This document presents the design features, performance metrics and application potential of the UltiMate 3000 Series Rapid Separation Pump family. The goal is to demonstrate how binary, quaternary and dual‐gradient pump systems deliver unmatched flow‐pressure footprints, advanced mixing technologies and flexible solvent handling to support a wide range of HPLC and UHPLC workflows.
Methodology and Instrumentation
The UltiMate 3000 Series includes four models of Rapid Separation Pumps:
- Binary Rapid Separation Pump with high‐pressure proportioning (0.001–8 mL/min, up to 103 MPa at 5 mL/min)
- Binary Rapid Separation Pump with solvent selector valves
- Quaternary Rapid Separation Pump providing four‐solvent capability with built-in micromembrane degassing
- Dual‐Gradient Rapid Separation Pump combining two ternary gradient streams in one enclosure
Key engineering features:
- SmartFlow® technology with automatic compressibility compensation
- SpinFlow mixing design to minimize gradient delay volumes (35–200 µL) while maximizing mixing efficiency
- Active rear‐seal wash system for extended seal lifetime and reduced downtime
- AutoQ™ equipment qualification tests and predictive performance monitoring
- Front‐panel access for rapid maintenance and solvent rack connectivity via USB and I/O interfaces
Main Results and Discussion
Performance evaluations highlighted:
- Industry‐leading flow‐pressure footprint covering conventional LC (up to 80 MPa at 8 mL/min) through UHPLC (103 MPa at 5 mL/min)
- Retention time precision better than 0.05 % RSD demonstrated with simvastatin at 3.35 mL/min and 74 MPa
- Ternary gradient separation of forensic ink dyes achieved in one sixth of the time compared with conventional methods
- Dual‐gradient operation enabling tandem or parallel UHPLC modes to effectively double sample throughput without re-plumbing
Benefits and Practical Applications
These pump systems offer clear advantages for pharmaceutical quality control, environmental testing, forensic analyses and LC–MS workflows:
- High throughput screening with minimal gradient delay
- Robust performance under extreme backpressures
- Flexible method development via multisolvent mixing and quick solvent switching
- Space-saving footprint and automated diagnostics for streamlined laboratory operation
Future Trends and Opportunities
Emerging directions include integration of dual‐gradient pumps into multidimensional LC configurations, expanded automation for real‐time instrument health monitoring, advanced software-driven method translation between HPLC and UHPLC, and scale-up potential for preparative separations using similar high‐pressure platforms.
Conclusion
The UltiMate 3000 Series Rapid Separation Pumps set a new standard in chromatographic performance by combining high pressure tolerance, precise flow control and advanced mixing technologies. Their versatility and reliability make them an essential tool for modern analytical laboratories seeking to maximize speed, resolution and operational efficiency.
References
No specific references were provided in the source document.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Thermo Scientific Dionex UltiMate 3000 Pumps - Product Specifications
2016|Thermo Fisher Scientific|Brochures and specifications
C H R O M ATO G R A P H Y The Benchmark in LC Solvent Delivery Produ c t Spe ci f i cat i ons Thermo Scientific Dionex UltiMate 3000 Pumps Thermo Scientific™ Dionex™ UltiMate™ 3000 products…
Key words
proportioning, proportioningxrs, xrspumps, pumpspump, pumpbiocompatible, biocompatiblecylinder, cylinderbio, biopurge, purgevalve, valvepressure, pressureunrivaled, unrivaledflow, flowmixer, mixeroptional, optionalhpg
Thermo Scientific Dionex UltiMate 3000 RSLC Systems
2016|Thermo Fisher Scientific|Brochures and specifications
Thermo Scientific Dionex UltiMate 3000 RSLC Systems Rapid separation systems high-end performance Speed • Resolution • Versatility Rapid separation LC accelerate your analysis The Thermo Scientific Dionex UltiMate 3000 Rapid Separation LC (RSLC) systems accelerate HPLC for unrivaled performance and…
Key words
rslc, rslcmau, mauuhplc, uhplcseconds, secondsminutes, minutesresolution, resolutionaas, aaschromeleon, chromeleonviper, viperconventional, conventionalscouting, scoutinghighest, highestfingertight, fingertightspeed, speedfitting
Tune Your Mixing Volume for Gradient Generation to Achieve Better Detection Limits
2016|Thermo Fisher Scientific|Technical notes
Te ch ni ca l N ote 1 4 1 Tune Your Mixing Volume for Gradient Generation to Achieve Better Detection Limits Christian Schmidt, Thermo Fisher Scientific, Germering, Germany Keywords Baseline Ripples, Gradient Formation, High-pressure Gradient Proportioning, HPG, Low-pressure Gradient…
Key words
mixing, mixinghead, headpump, pumpmixer, mixervalve, valvecylinder, cylinderproportioning, proportioningripples, ripplessolvents, solventspurge, purgeextinction, extinctiongradient, gradientclosing, closingfluctuations, fluctuationstee
Thermo Scientific Dionex UltiMate 3000 Series - SD, RS, BM, and BX Pumps
2013|Thermo Fisher Scientific|Manuals
Thermo Scientific Dionex UltiMate 3000 Series SD, RS, BM, and BX Pumps Operating Instructions (Original Operating Instructions) Revision: 1.7 Date: September 2013 © 2013 Thermo Fisher Scientific Doc. No. 4820.4001 UltiMate 3000 Series: SD, RS, BM, and BX Pumps Operating…
Key words
instructions, instructionsoperating, operatingpump, pumpseal, sealwash, washpiston, pistonhead, headcylinder, cylinderincluded, includedpressure, pressurepurge, purgerear, rearchromeleon, chromeleonvalve, valvepumps