Analysis of Immunosupressant Drugs in Whole Blood Using a High-Efficiency Method on an Affordable High-Resolution Mass Spectrometer

Applications | 2015 | Thermo Fisher ScientificInstrumentation
LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap
Industries
Clinical Research
Manufacturer
Thermo Fisher Scientific

Summary

Significance of the Topic


Precise quantification of immunosuppressant drugs in whole blood is crucial for therapeutic drug monitoring in transplant patients and for research in autoimmune conditions. High selectivity and throughput are required to support clinical decision making and large-scale studies.

Objectives and Study Overview


This study aimed to assess the performance of the Thermo Scientific Q Exactive Focus hybrid quadrupole-Orbitrap mass spectrometer coupled with a rapid HPLC method for quantitative analysis of four immunosuppressants. The method was compared to a conventional triple quadrupole approach and evaluated for accuracy, precision, linearity and matrix effects.

Methodology


Sample preparation involved protein precipitation of 100 µL whole blood with zinc sulfate and methanol containing internal standards. Calibration standards and quality control samples were sourced from a commercial kit covering relevant concentration ranges. Method performance was assessed over multiple days with replicate measurements for inter- and intra-day precision and accuracy. Matrix effects were evaluated using spiked donor samples and the method was cross-validated against a collaborator triple quadrupole method.

Instrumentation


  • Liquid chromatograph: Thermo Scientific Dionex UltiMate 3000RS with OAS autosampler
  • Mass spectrometer: Thermo Scientific Q Exactive Focus Orbitrap with Ion Max source and HESI-II probe
  • Data system: Thermo Scientific TraceFinder software in parallel-reaction monitoring mode

Main Results and Discussion


Limits of quantitation were equivalent to the lowest calibration levels (2.27–26.1 ng/mL). All analytes demonstrated linear calibration curves with R2 > 0.97. Intra- and inter-assay precision was better than 7% RSD and accuracy within ±17% at the lowest QC and ±10% at higher levels. Matrix recoveries ranged from 82% to 112%, indicating minimal matrix interference. Comparison with the triple quadrupole method showed excellent agreement (slope ~1, R2 > 0.97).

Benefits and Practical Applications


Compared to traditional triple quadrupole methods, this high-resolution approach offers improved selectivity by using high-accuracy mass measurements, reduces analysis time with a two-minute gradient, and can be scaled to high throughput with multi-channel LC systems for clinical research laboratories.

Future Trends and Applications


Advances may include integration of multiplexed microflow or nanoLC systems, application to additional drug classes, automated sample preparation workflows and use of data-driven algorithms for enhanced quantitation and quality control in clinical environments.

Conclusion


The Q Exactive Focus Orbitrap mass spectrometer, combined with rapid HPLC and targeted PRM acquisition, provides a robust, high-throughput solution for quantitative analysis of immunosuppressant drugs in whole blood, meeting the stringent requirements of clinical research.

References


  • Gao M, Kozak M. Analysis of Immunosuppressant Drugs in Whole Blood Using a High-Efficiency Method on an Affordable High-Resolution Mass Spectrometer. Thermo Fisher Scientific Application Note 632; 2015.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Evaluation of Benchtop Quadrupole Orbitrap Ultra-High-Resolution Mass Spectrometer in Rapid Quantitative Analysis of Immunosuppressant Drugs in Blood Samples
Methods Calibrators Calibrators containing cyclosporin A, everolimus, sirolimus, and tacrolimus in whole blood were purchased from Chromsystems Instruments & Chemicals GmbH (TABLE 1). Evaluation of Benchtop Quadrupole Orbitrap Ultra-High-Resolution Mass Spectrometer in Rapid Quantitative Analysis of Immunosuppressant Evaluation of Benchtop…
Key words
cyclosporin, cyclosporintacrolimus, tacrolimuseverolimus, everolimussirolimus, sirolimusquantifier, quantifierrelative, relativeimmunosuppressant, immunosuppressantanalyte, analyteabundance, abundanceblood, bloodascomycin, ascomycinquadrupole, quadrupolepositive, positiveclinical, clinicalorbitrap
Quantification of immunosuppressants in human blood by LC-HRAM mass spectrometry for clinical research
TECHNICAL NOTE 66003 Quantification of immunosuppressants in human blood by LC-HRAM mass spectrometry for clinical research Authors: Claudio De Nardi1, Anke Deden2, Anne Behrens2, Sebastian Berger2 Thermo Fisher Scientific GmbH, Dreieich, Germany 1 RECIPE Chemicals + Instruments GmbH, Munich, Germany…
Key words
prm, prmfull, fullcalculated, calculatedscan, scancyclosporine, cyclosporineaverage, averagebias, biasconcentration, concentrationtac, tacsirolimus, sirolimuseverolimus, everolimustacrolimus, tacrolimuscic, cicmode, modenominal
Tomorrow’s quantitation: increased robustness for quantitation of immunosuppressant drugs in blood with the TSQ Fortis MS for clinical research
TECHNICAL NOTE 65206 Tomorrow’s quantitation: increased robustness for quantitation of immunosuppressant drugs in blood with the TSQ Fortis MS for clinical research Authors Neloni Wijeratne, Claudia Martins, Kristine Van Natta, Xiaolei Xie, Thermo Fisher Scientific, San Jose, CA Debadeep Bhattacharyya,…
Key words
fortis, fortiscleaning, cleaningimmunosuppressant, immunosuppressanttsq, tsqcyclosporin, cyclosporintriple, triplesirolimus, sirolimuseverolimus, everolimusquantitation, quantitationtacrolimus, tacrolimusblood, blooddrugs, drugsafter, afterbefore, beforequadrupole
Quantification of immunosuppressants in human whole blood by liquid chromatography-tandem mass spectrometry for clinical research
TECHNICAL NOTE 64916 Quantification of immunosuppressants in human whole blood by liquid chromatography-tandem mass spectrometry for clinical research Authors Claudio De Nardi,1 Katharina Kern,2 Steffen Peters2 Thermo Fisher Scientific GmbH, Dreieich, Germany 2 RECIPE Chemicals + Instruments GmbH, Munich, Germany…
Key words
cyclosporin, cyclosporineverolimus, everolimussirolimus, sirolimustacrolimus, tacrolimusconcentration, concentrationrecipe, recipeaverage, averagebias, biasimmunosuppressants, immunosuppressantsprecipitation, precipitationabundance, abundanceendura, enduraminutes, minutescontrols, controlsrelative
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike