Summary

Significance of the Topic


The precise measurement of immunosuppressant levels in human whole blood is critical for patient management after organ transplantation and for research into therapeutic drug monitoring. Combining multiple analytes in a single rapid assay supports clinical decision making and improves laboratory throughput while preserving accuracy and sensitivity.

Objectives and Study Overview


This work describes the development and validation of a liquid chromatography–tandem mass spectrometry (LC-MS/MS) method to quantify four key immunosuppressants—cyclosporin A, tacrolimus, sirolimus, and everolimus—in human whole blood. The approach integrates minimal sample preparation with online solid phase extraction for streamlined analysis within a two-minute total runtime.

Methodology and Instrumentation


Sample preparation begins with protein precipitation and addition of isotopically labeled internal standards, followed by online SPE on a Transcend II TLX-1 system. Chromatographic separation employs RECIPE SPE cartridges and analytical columns. Detection is achieved on a Thermo Scientific TSQ Endura triple quadrupole mass spectrometer with heated electrospray ionization operating in positive mode. Two selected reaction monitoring transitions per analyte allow simultaneous quantification and confirmation. Data processing is performed using Thermo Scientific TraceFinder 3.3 software.

Main Results and Discussion


Linearity was demonstrated over broad concentration ranges for each analyte, with correlation coefficients (R2) exceeding 0.99. Lower limits of quantification were determined as 14.0 ng/mL for cyclosporin A, 0.85 ng/mL for everolimus, 1.87 ng/mL for sirolimus, and 0.31 ng/mL for tacrolimus. Accuracy assessments using external proficiency test samples yielded biases between −21.5% and +15.1%. Intra-assay precision (%CV) remained below 9.9% at all concentration levels, and inter-assay precision did not exceed 12.9%, meeting stringent criteria for research use.

Benefits and Practical Applications


  • Simultaneous quantification of four immunosuppressants in a single, rapid run.
  • Minimal offline sample handling reduces potential for error and increases throughput.
  • High sensitivity and broad dynamic range suitable for clinical research and therapeutic drug monitoring studies.

Future Trends and Applications


Advances in online sample preparation and mass spectrometric detection will continue to shorten analysis times while enhancing multiplexing capabilities. Integration with laboratory information management systems and the use of high-resolution MS may further improve selectivity, enabling broader panels of analytes and metabolite profiling in transplant pharmacokinetics.

Conclusion


The described LC-MS/MS method provides a robust, accurate, and precise tool for quantifying cyclosporin A, everolimus, sirolimus, and tacrolimus in human whole blood. Its streamlined workflow and rapid two-minute analysis support high-throughput clinical research applications.

Reference


  • De Nardi C., Kern K., Peters S. Quantification of immunosuppressants in human whole blood by liquid chromatography-tandem mass spectrometry for clinical research. Technical Note 64916, Thermo Fisher Scientific, 2017.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Confident quantitation for every user: immunosuppressants in human blood by liquid chromatography-tandem mass spectrometry for clinical research
TECHNICAL NOTE 65439 Confident quantitation for every user: immunosuppressants in human blood by liquid chromatography-tandem mass spectrometry for clinical research Application benefits Authors Claudio De Nardi, Paolo Brambilla, Maura Brambilla,2 Chiara Fania3 1 Thermo Fisher Scientific GmbH, Dreieich, Germany; 2…
Key words
cyclosporine, cyclosporinecalculated, calculatedchromsystems, chromsystemsfour, fourcalibrators, calibratorsimmunosuppressants, immunosuppressantsaverage, averageeverolimus, everolimussirolimus, sirolimustacrolimus, tacrolimusquantis, quantismin, mintransplanted, transplantedinternal, internalpercentage
Quantification of immunosuppressants in human blood by LC-HRAM mass spectrometry for clinical research
TECHNICAL NOTE 66003 Quantification of immunosuppressants in human blood by LC-HRAM mass spectrometry for clinical research Authors: Claudio De Nardi1, Anke Deden2, Anne Behrens2, Sebastian Berger2 Thermo Fisher Scientific GmbH, Dreieich, Germany 1 RECIPE Chemicals + Instruments GmbH, Munich, Germany…
Key words
prm, prmfull, fullcalculated, calculatedscan, scancyclosporine, cyclosporineaverage, averagebias, biasconcentration, concentrationtac, tacsirolimus, sirolimuseverolimus, everolimustacrolimus, tacrolimuscic, cicmode, modenominal
Exemplary performance data for immunosuppressants
Exemplary performance data for immunosuppressants
2020|Thermo Fisher Scientific|Technical notes
DATA SHEET LC-MS Medical Devices For In Vitro Diagnostic Use Exemplary performance data for immunosuppressants Analytical performance of clinically relevant compounds TSQ Quantis MD Triple-Stage Quadrupole Mass Spectrometer | Vanquish MD HPLC Preface Liquid chromatography systems Intended use: The Thermo…
Key words
pass, passqciii, qciiiqcv, qcvdiff, diffcyclosporin, cyclosporinsirolimus, sirolimuseverolimus, everolimustacrolimus, tacrolimusrsd, rsdcalibrator, calibratorimmunosuppressants, immunosuppressantstsq, tsqvanquish, vanquishquantis, quantisrecipe
Quantification of four immunosuppressants in human blood by LC-HRAM-MS for clinical research
TECHNICAL NOTE 000296 Quantification of four immunosuppressants in human blood by LC-HRAM-MS for clinical research Authors: Gaëtan Renoulin1, Claudio De Nardi2, Mariana Barcenas1, Katharina Kern3 1 Thermo Fisher Scientific, Les Ulis, France 2 Thermo Fisher Scientific, Reinach, Switzerland 3 RECIPE…
Key words
intensity, intensitylevel, levelmin, minarea, arearatio, ratioimmunosuppressants, immunosuppressantscyclosporine, cyclosporineiii, iiisirolimus, sirolimuseverolimus, everolimustacrolimus, tacrolimusformate, formatearb, arbcalculated, calculatedpercentage
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike