Confident quantitation for every user: immunosuppressants in human blood by liquid chromatography-tandem mass spectrometry for clinical research
Applications | 2019 | Thermo Fisher ScientificInstrumentation
Therapeutic monitoring of immunosuppressive drugs is essential to prevent graft rejection and drug toxicity in organ-transplanted patients. Liquid chromatography-tandem mass spectrometry offers superior selectivity and specificity compared to traditional immunoassays, enabling accurate quantification of multiple immunosuppressants in a single run.
This study aimed to develop and validate a robust LC-MS/MS method for simultaneous quantification of four immunosuppressants—tacrolimus, sirolimus, everolimus, and cyclosporine A—in human blood using a Thermo Scientific TSQ Quantis triple quadrupole mass spectrometer coupled to a Transcend LX-2 UHPLC system.
Sample preparation:
The method showed excellent linearity (R2 > 0.999) across calibration ranges, negligible carryover, accuracy bias within ±6.3%, and intra- and inter-assay precision with CVs below 7.3%. Representative chromatograms and calibration curves confirmed sensitivity at low nanogram-per-milliliter levels.
• Simple offline sample preparation and rapid analysis increase laboratory throughput.
• Simultaneous quantification of four key immunosuppressants in a single assay run.
• High sensitivity and precision support reliable therapeutic drug monitoring in clinical research.
Future developments may include integration with automated sample handling, expansion to additional drug panels, miniaturization for finger-prick blood samples, and real-time data processing with advanced software for individualized dosing algorithms.
The presented LC-MS/MS method on the Transcend LX-2 and TSQ Quantis platform provides a rapid, sensitive, and precise approach for comprehensive immunosuppressant quantification in human blood, meeting clinical research requirements.
De Nardi C, Brambilla P, Brambilla M, Fania C. Confident quantitation for every user: immunosuppressants in human blood by liquid chromatography-tandem mass spectrometry for clinical research. Thermo Fisher Scientific Technical Note 65439; 2019.
LC/MS, LC/MS/MS, LC/QQQ
IndustriesClinical Research
ManufacturerThermo Fisher Scientific
Summary
Význam tématu
Therapeutic monitoring of immunosuppressive drugs is essential to prevent graft rejection and drug toxicity in organ-transplanted patients. Liquid chromatography-tandem mass spectrometry offers superior selectivity and specificity compared to traditional immunoassays, enabling accurate quantification of multiple immunosuppressants in a single run.
Cíle a přehled studie
This study aimed to develop and validate a robust LC-MS/MS method for simultaneous quantification of four immunosuppressants—tacrolimus, sirolimus, everolimus, and cyclosporine A—in human blood using a Thermo Scientific TSQ Quantis triple quadrupole mass spectrometer coupled to a Transcend LX-2 UHPLC system.
Použitá metodika a instrumentace
Sample preparation:
- Offline protein precipitation of 100 µL blood with 0.1 M ZnSO4 and methanol containing isotopically labeled internal standards.
- Centrifugation and transfer of supernatant to analysis plate.
- Thermo Scientific Transcend LX-2 dual-channel UHPLC.
- Hypersil GOLD column 50×2.1 mm, 1.9 µm, at 60 °C.
- Gradient elution with water and methanol (10 mM ammonium formate, 0.1% formic acid) and organic mixture of acetonitrile/acetone/2-propanol.
- Three-and-a-half minute runtime.
- Thermo Scientific TSQ Quantis triple quadrupole with heated electrospray ionization in positive mode.
- Selected-reaction monitoring with two transitions per analyte.
- Calibration with 1/x weighted linear interpolation.
Hlavní výsledky a diskuse
The method showed excellent linearity (R2 > 0.999) across calibration ranges, negligible carryover, accuracy bias within ±6.3%, and intra- and inter-assay precision with CVs below 7.3%. Representative chromatograms and calibration curves confirmed sensitivity at low nanogram-per-milliliter levels.
Přínosy a praktické využití metody
• Simple offline sample preparation and rapid analysis increase laboratory throughput.
• Simultaneous quantification of four key immunosuppressants in a single assay run.
• High sensitivity and precision support reliable therapeutic drug monitoring in clinical research.
Budoucí trendy a možnosti využití
Future developments may include integration with automated sample handling, expansion to additional drug panels, miniaturization for finger-prick blood samples, and real-time data processing with advanced software for individualized dosing algorithms.
Závěr
The presented LC-MS/MS method on the Transcend LX-2 and TSQ Quantis platform provides a rapid, sensitive, and precise approach for comprehensive immunosuppressant quantification in human blood, meeting clinical research requirements.
Reference
De Nardi C, Brambilla P, Brambilla M, Fania C. Confident quantitation for every user: immunosuppressants in human blood by liquid chromatography-tandem mass spectrometry for clinical research. Thermo Fisher Scientific Technical Note 65439; 2019.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Quantification of immunosuppressants in human blood by LC-HRAM mass spectrometry for clinical research
2021|Thermo Fisher Scientific|Applications
TECHNICAL NOTE 66003 Quantification of immunosuppressants in human blood by LC-HRAM mass spectrometry for clinical research Authors: Claudio De Nardi1, Anke Deden2, Anne Behrens2, Sebastian Berger2 Thermo Fisher Scientific GmbH, Dreieich, Germany 1 RECIPE Chemicals + Instruments GmbH, Munich, Germany…
Key words
prm, prmfull, fullcalculated, calculatedscan, scancyclosporine, cyclosporineaverage, averagebias, biasconcentration, concentrationtac, tacsirolimus, sirolimuseverolimus, everolimustacrolimus, tacrolimuscic, cicmode, modenominal
Quantification of immunosuppressants in human whole blood by liquid chromatography-tandem mass spectrometry for clinical research
2017|Thermo Fisher Scientific|Applications
TECHNICAL NOTE 64916 Quantification of immunosuppressants in human whole blood by liquid chromatography-tandem mass spectrometry for clinical research Authors Claudio De Nardi,1 Katharina Kern,2 Steffen Peters2 Thermo Fisher Scientific GmbH, Dreieich, Germany 2 RECIPE Chemicals + Instruments GmbH, Munich, Germany…
Key words
cyclosporin, cyclosporineverolimus, everolimussirolimus, sirolimustacrolimus, tacrolimusconcentration, concentrationrecipe, recipeaverage, averagebias, biasimmunosuppressants, immunosuppressantsprecipitation, precipitationabundance, abundanceendura, enduraminutes, minutescontrols, controlsrelative
Quantification of four immunosuppressants in human blood by LC-HRAM-MS for clinical research
2021|Thermo Fisher Scientific|Applications
TECHNICAL NOTE 000296 Quantification of four immunosuppressants in human blood by LC-HRAM-MS for clinical research Authors: Gaëtan Renoulin1, Claudio De Nardi2, Mariana Barcenas1, Katharina Kern3 1 Thermo Fisher Scientific, Les Ulis, France 2 Thermo Fisher Scientific, Reinach, Switzerland 3 RECIPE…
Key words
intensity, intensitylevel, levelmin, minarea, arearatio, ratioimmunosuppressants, immunosuppressantscyclosporine, cyclosporineiii, iiisirolimus, sirolimuseverolimus, everolimustacrolimus, tacrolimusformate, formatearb, arbcalculated, calculatedpercentage
Exemplary performance data for immunosuppressants
2020|Thermo Fisher Scientific|Technical notes
DATA SHEET LC-MS Medical Devices For In Vitro Diagnostic Use Exemplary performance data for immunosuppressants Analytical performance of clinically relevant compounds TSQ Quantis MD Triple-Stage Quadrupole Mass Spectrometer | Vanquish MD HPLC Preface Liquid chromatography systems Intended use: The Thermo…
Key words
pass, passqciii, qciiiqcv, qcvdiff, diffcyclosporin, cyclosporinsirolimus, sirolimuseverolimus, everolimustacrolimus, tacrolimusrsd, rsdcalibrator, calibratorimmunosuppressants, immunosuppressantstsq, tsqvanquish, vanquishquantis, quantisrecipe