Installation Instruction for ProfIC Vario 10 Anion
Manuals | | MetrohmInstrumentation
The effective inline neutralization of acidic or alkaline samples in ion chromatography is critical for maintaining column integrity and generating reliable results. The ProfIC Vario 10 Anion system with integrated neutralization streamlines sample preparation, reduces manual handling and contamination risk, and enhances throughput.
This bulletin provides step-by-step guidance on installing and configuring the ProfIC Vario 10 Anion system, including software setup, hardware assembly, capillary connections, and system validation to ensure fully automated anion analysis.
Key components include:
The recommended installation sequence covers:
Accurate capillary routing and secure coupling prevent leaks and carryover. Purging the system prior to column installation removes air and particulates. Defining rack positions and hardware components in MagIC Net ensures synchronized operation of the 940 IC Vario and 858 Sample Processor. Method parameters—such as suppressor flow rates, rotor configurations, column temperature, and standard concentrations—must be verified and adjusted for optimal peak resolution and retention times.
Automated inline neutralization enables direct analysis of harsh matrices without manual pH adjustment, improving reproducibility and reducing labor. The modular design supports high-throughput screening in environmental monitoring, food and beverage testing, pharmaceutical QA/QC, and industrial process control. Online eluent production and advanced liquid handling further reduce downtime and solvent consumption.
Future developments will integrate eluent auto-generation, enhanced liquid handling for multi-dilution workflows, and software-driven predictive maintenance to maximize uptime. Coupling with mass spectrometry and advanced data analytics will expand the scope of ion chromatography, enabling trace-level detection and real-time monitoring.
The ProfIC Vario 10 Anion system delivers a comprehensive, fully automated solution for anion analysis of challenging sample matrices. Adherence to the detailed installation and configuration protocol ensures robust performance, consistent data quality, and efficient laboratory workflows.
Application Bulletin 386: Installation Instruction for ProfIC Vario 10 Anion
Ion chromatography
IndustriesManufacturerMetrohm
Summary
Importance of the Topic
The effective inline neutralization of acidic or alkaline samples in ion chromatography is critical for maintaining column integrity and generating reliable results. The ProfIC Vario 10 Anion system with integrated neutralization streamlines sample preparation, reduces manual handling and contamination risk, and enhances throughput.
Aims and Overview
This bulletin provides step-by-step guidance on installing and configuring the ProfIC Vario 10 Anion system, including software setup, hardware assembly, capillary connections, and system validation to ensure fully automated anion analysis.
Methodology and Instrumentation
Key components include:
- 940 Professional IC Vario with inline suppressor modules
- 858 Professional Sample Processor for automated injection and inline neutralization
- Accessory Kits Vario/Flex Basic and ONE for detector, eluent, and sample rack integration
- 941 Eluent Production Module for on-demand eluent generation
- Liquid Handling (LQH) Station and Dosino for needle rinsing and optional dilution
- MagIC Net software for instrument control, method setup, and data evaluation
The recommended installation sequence covers:
- MagIC Net software installation and driver setup
- Assembly of Vario/Flex accessories, sample racks, and waste collectors
- Connection of peristaltic pumps, capillaries, suppressors, columns, and detectors
- Import of predefined anion method and equipment assignment in MagIC Net
- System purge, suppressor and column rinsing, and baseline equilibration
Main Discussion
Accurate capillary routing and secure coupling prevent leaks and carryover. Purging the system prior to column installation removes air and particulates. Defining rack positions and hardware components in MagIC Net ensures synchronized operation of the 940 IC Vario and 858 Sample Processor. Method parameters—such as suppressor flow rates, rotor configurations, column temperature, and standard concentrations—must be verified and adjusted for optimal peak resolution and retention times.
Benefits and Practical Applications
Automated inline neutralization enables direct analysis of harsh matrices without manual pH adjustment, improving reproducibility and reducing labor. The modular design supports high-throughput screening in environmental monitoring, food and beverage testing, pharmaceutical QA/QC, and industrial process control. Online eluent production and advanced liquid handling further reduce downtime and solvent consumption.
Future Trends and Potential Uses
Future developments will integrate eluent auto-generation, enhanced liquid handling for multi-dilution workflows, and software-driven predictive maintenance to maximize uptime. Coupling with mass spectrometry and advanced data analytics will expand the scope of ion chromatography, enabling trace-level detection and real-time monitoring.
Conclusion
The ProfIC Vario 10 Anion system delivers a comprehensive, fully automated solution for anion analysis of challenging sample matrices. Adherence to the detailed installation and configuration protocol ensures robust performance, consistent data quality, and efficient laboratory workflows.
References
Application Bulletin 386: Installation Instruction for ProfIC Vario 10 Anion
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Installation Instruction for ProfIC Vario 8 Anion
|Metrohm|Manuals
Application Bulletin 381 Installation Instruction for ProfIC Vario 8 Anion The ProfIC Vario 8 Anion is a Professional IC Vario system with Inline Sample Preconcentration and Matrix Elimination for anions or cations with sequential suppression. «ProfIC Vario 8» safely masters…
Key words
msm, msmstation, stationrinsing, rinsingconnected, connectedregeneration, regenerationhandling, handlingrotor, rotorcapillary, capillarylabeled, labeledsuppressor, suppressormcs, mcssolution, solutionpump, pumpliquid, liquidperistaltic
Installation Instruction for ProfIC Vario 2 Anion
|Metrohm|Manuals
Application Bulletin 365 Installation Instruction for ProfIC Vario 2 Anion ProfIC Vario 2 Anion is a Professional IC Vario system for the fully automatic determination of anions or cations with sequential suppression with Metrohm Inline Ultrafiltration. «ProfIC Vario 2» safely…
Key words
msm, msmstation, stationrinsing, rinsingregeneration, regenerationultrafiltration, ultrafiltrationhandling, handlingconnected, connectedrotor, rotorperistaltic, peristalticcapillary, capillarylabeled, labeledstoppers, stoppersexemplary, exemplarysuppressor, suppressormcs
Installation Instruction for ProfIC Vario 1 Anion
|Metrohm|Manuals
Application Bulletin 359 Installation Instruction for ProfIC Vario 1 Anion ProfIC Vario 1 Anion is a Professional IC Vario system for the fully automatic determination of anions or cations with sequential suppression. «ProfIC Vario 1» safely masters all routine tasks…
Key words
msm, msmrinsing, rinsingstation, stationcapillary, capillaryperistaltic, peristalticregeneration, regenerationconnected, connectedrotor, rotorpump, pumplabeled, labeledexemplary, exemplarysuppressor, suppressormcs, mcshandling, handlingeluent
Installation Instruction for ProfIC Vario 11 Anion
|Metrohm|Manuals
Application Bulletin 387 Installation Instruction for ProfIC Vario 11 Anion ProfIC Vario 11 - Anion is a Professional IC Vario system with variable sample Preconcentration, Matrix Neutralization and Matrix Elimination for trace analysis of anions. With the «ProfIC Vario 11»,…
Key words
msm, msmprocessor, processorrinsing, rinsingspm, spmdosino, dosinodosing, dosingcapillary, capillarylabeled, labeledsample, sampleconnected, connectedrotor, rotoroutlet, outletregeneration, regenerationcapillaries, capillariesvario