Installation instructions TitrIC flex I
Manuals | | MetrohmInstrumentation
In modern water analysis efficient measurement of multiple parameters is essential for environmental monitoring process control and quality assurance. The TitrIC flex I system integrates direct measurement titration and ion chromatography into a single automated workflow. This approach reduces manual handling accelerates turnaround times and delivers reproducible results in routine laboratory and industrial applications.
This application bulletin provides a step by step guide for installing and configuring the TitrIC flex I system. It covers mechanical assembly of modules software installation driver setup and the integration of Metrohm instruments under MagIC Net and OMNIS control. The goal is to enable fully automated analysis of water samples for temperature conductivity pH alkalinity hardness and individual anion concentrations.
The installation protocol is divided into hardware setup and software integration. Key steps include:
Following the prescribed installation ensures:
The unified platform offers several advantages:
Upcoming developments in automated analytical platforms include:
The TitrIC flex I installation bulletin delivers a comprehensive procedure for setting up a fully automated water analysis system integrating ion chromatography titration and sensor measurements. Adherence to the detailed mechanical and software commissioning steps ensures reliable performance data integrity and operational flexibility. The modular architecture supports future expansions and evolving analytical workflows.
No references provided in the source bulletin.
Ion chromatography
IndustriesManufacturerMetrohm
Summary
Importance of the Topic
In modern water analysis efficient measurement of multiple parameters is essential for environmental monitoring process control and quality assurance. The TitrIC flex I system integrates direct measurement titration and ion chromatography into a single automated workflow. This approach reduces manual handling accelerates turnaround times and delivers reproducible results in routine laboratory and industrial applications.
Aims and Overview of the Bulletin
This application bulletin provides a step by step guide for installing and configuring the TitrIC flex I system. It covers mechanical assembly of modules software installation driver setup and the integration of Metrohm instruments under MagIC Net and OMNIS control. The goal is to enable fully automated analysis of water samples for temperature conductivity pH alkalinity hardness and individual anion concentrations.
Applied Methodology and Instrumentation
The installation protocol is divided into hardware setup and software integration. Key steps include:
- Placement and interconnection of the 930 Compact IC Flex 800 Dosino Sample Robot S Titrator Dosing Module and 856 Conductometer
- Mounting of accessory kits for eluent supply inline ultrafiltration and Dosino regeneration
- Routing of FEP and PTFE capillaries for sample transfer regeneration and waste management
- Installation of MagIC Net and OMNIS software with automatic driver recognition and RS232 configuration
- Configuration of MagIC Net method templates for combined IC titration sequences including direct conductivity measurement pH and hardness determination
- OMNIS setup by reserving instruments assigning functional units defining solutions importing OP templates and creating sample profiles
- Synchronization of MagIC Net and OMNIS via serial device communication for unified data flow
Main Results and Discussion
Following the prescribed installation ensures:
- Seamless communication between IC conductivity and titration modules via RS232
- Reliable sample handling through synchronized MagIC Net and OMNIS control sequences
- Consistent acquisition of chromatographic titration and sensor data in a single run
- Effective inline removal of particulates and stable baseline delivered by regular membrane regeneration
Benefits and Practical Applications
The unified platform offers several advantages:
- Reduction of manual interventions and associated error risks
- Capability for unattended overnight and multi day analysis
- Compliance monitoring in environmental food pharmaceutical and industrial quality control laboratories
- Modular expandability allowing easy addition of further Metrohm instruments
Future Trends and Applications
Upcoming developments in automated analytical platforms include:
- Inline eluent preparation modules for extended runtime without manual reagent refill
- Automated lid handling features to prevent sample evaporation and CO2 absorption
- Integration of real time data analytics remote monitoring and cloud based reporting
- Incorporation of additional sensors for metal speciation total organic carbon and salinity
Conclusion
The TitrIC flex I installation bulletin delivers a comprehensive procedure for setting up a fully automated water analysis system integrating ion chromatography titration and sensor measurements. Adherence to the detailed mechanical and software commissioning steps ensures reliable performance data integrity and operational flexibility. The modular architecture supports future expansions and evolving analytical workflows.
References
No references provided in the source bulletin.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Installation instructions TitrIC flex II
|Metrohm|Manuals
Application Bulletin 437 Installation instructions TitrIC flex II The TitrIC flex II system is used for the fully automatic analysis of water samples using direct measurement, titration, and ion chromatography. The following parameters are determined within a very short time:…
Key words
titric, titricomnis, omnisrobot, robotflex, flexinstructions, instructionsinstallation, installationsample, sampletitration, titrationmsm, msmtubing, tubinglid, lidconductivity, conductivitymodule, modulestirrer, stirreranion
Comprehensive water analysis with TitrIC flex II
2020|Metrohm|Applications
IC Application Note S–387 Comprehensive water analysis with TitrIC flex II Determination of pH, temperature, conductivity, m- and p-value, anions, and cations Chromatogram of several anions and cations present in well water. The TitrIC flex II system is the perfect…
Key words
pmax, pmaxrobot, robotpick, pickstirrer, stirrerrecording, recordingcations, cationssum, sumtitration, titrationcarbonate, carbonateanions, anionsinstrumentation, instrumentationtitric, titricion, ionvalue, valueconductivity
Installation Instruction for ProfIC Vario 6 Anion
|Metrohm|Manuals
Application Bulletin 376 Installation Instruction for ProfIC Vario 6 Anion The ProfIC Vario 6 Anion is a Professional IC Vario system with Inline Dilution and Inline Ultrafiltration for the fully automatic determination of anions or cations with sequential suppression in…
Key words
msm, msmrinsing, rinsingpump, pumpultrafiltration, ultrafiltrationconnected, connectedrotor, rotorperistaltic, peristaltictubing, tubingregeneration, regenerationstation, stationprofic, proficcapillary, capillarylabeled, labeledcapillaries, capillariesstoppers
Installation Instruction for ProfIC Vario 6 AnCat
|Metrohm|Manuals
Application Bulletin 378 Installation Instruction for ProfIC Vario 6 AnCat The ProfIC Vario 6 AnCat is a Professional IC Vario system with Inline Dilution and Inline Ultrafiltration for the fully automatic and parallel determination of anions and cations in very…
Key words
msm, msmrinsing, rinsingpump, pumpconnected, connectedexemplary, exemplaryperistaltic, peristalticultrafiltration, ultrafiltrationmcs, mcsrotor, rotorconnection, connectionprocessor, processorstandard, standardregeneration, regenerationanion, anioncapillaries