LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Metrohm: The column program

Brochures and specifications | 2021 | MetrohmInstrumentation
Consumables, Ion chromatography, LC columns
Industries
Manufacturer
Metrohm

Summary

Comprehensive Approach to High-Performance Ion Chromatography


Introduction: Ion chromatography (IC) is a critical analytical tool for quantifying ionic species in diverse matrices. Metrohm has delivered innovations in separation columns and suppression modules for over 30 years, enabling robust, reproducible, and sensitive analyses of anions, cations, organic acids, carbohydrates, and amino acids.

Importance of the topic
IC is indispensable in environmental monitoring, pharmaceuticals, food and beverage testing, nuclear power plant water analysis, and industrial quality control. Precise separation of ionic analytes, even at trace levels, ensures regulatory compliance and process optimization across industries.

Study overview
This whitepaper presents Metrohm’s portfolio of IC columns, inline eluent preparation, suppressors, and instrument modules. It highlights column families for different analyte classes, the iColumn concept for intelligent column management, and tailored methodologies for high sensitivity and throughput.

Methodology and Instrumentation
  • Separation columns: Polystyrene-divinylbenzene, polyvinyl alcohol, polymethacrylate, and silica-based chemistries for anionic and cationic species, organic acids, carbohydrates, and amino acids.
  • Suppression techniques: Chemical suppression (MSM) and CO₂ suppression (MCS) to lower background conductivity and enhance detection limits.
  • Inline eluent preparation: Automatic dilution on-line to maintain stable eluent composition and retention reproducibility.
  • iColumn system: Embedded memory and software integration for method parameters, real-time monitoring, and GLP-compliant traceability.

Main Results and Discussion
Metrohm’s column portfolio covers applications from rapid screening (50–100 mm microbore columns consuming <0.3 mL/min) to high-capacity separations (250 mm columns) for complex matrices. Inline eluent production afforded <0.1% RSD in retention times over 20 days. Suppression modules yielded sub-µS/cm background conductivity, reducing detection limits by factors of 2–10.

Benefits and practical applications
  • Versatility: One column family per analyte class suits 90% of routine tasks.
  • Cost efficiency: Long column lifetimes and reduced reagent consumption.
  • Throughput: Fast separations in <5 minutes for standard anions/cations; specialized columns for organic acids and biomolecules.
  • Regulatory compliance: EPA, ISO, and DIN standards supported by column and system validation data.

Instrumentation
  • MagIC Net software and Metrohm IC systems (900 and 800 series) for automated workflows.
  • 940 Professional IC Vario/Compact IC Flex with integrated eluent degasser and inline suppressors.

Future trends and potential applications
Advances in microbore and monolithic columns will drive even faster, more sensitive analyses with lower eluent consumption. Coupling IC to high-resolution mass spectrometry will expand target lists to per- and polyfluoroalkyl substances (PFAS) and emerging contaminants. Smart columns with cloud-based lifecycle management will further streamline laboratory operations.

Conclusion
Metrohm’s comprehensive IC column and system solutions provide unmatched flexibility, reproducibility, and sensitivity across a wide range of applications. The integration of intelligent columns, inline eluent preparation, and advanced suppression modules ensures that modern laboratories can meet the ever-increasing demands for trace-level ionic analysis with confidence and efficiency.

References
Not applicable.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Metrosep A Supp 7 (Column manual)
Column manual Metrosep A Supp 7 (6.1006.6X0) Manual 8.107.8046EN / 2016-08-30 Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com Column manual Metrosep A Supp 7 (6.1006.6X0) Manual 8.107.8046EN /…
Key words
mcs, mcsmsm, msmcolumn, columnsequential, sequentialbromide, bromideconductivity, conductivityguard, guardeluent, eluentsuppression, suppressionseparation, separationnitrite, nitritefluoride, fluoridenitrate, nitratephosphate, phosphatesulfate
Metrosep A Supp 10 (Column manual)
Column manual Metrosep A Supp 10 (6.1020.XX0) Manual 8.0107.8009EN / 2021-10-08 Metrohm AG CH-9100 Herisau Switzerland +41 71 353 85 85 [email protected] www.metrohm.com Column manual Metrosep A Supp 10 (6.1020.XX0) Manual 8.0107.8009EN / 2021-10-08 Technical Communication Metrohm AG CH-9100 Herisau…
Key words
conductivity, conductivityeluent, eluentcolumn, columnmsm, msmmcs, mcsguard, guardsuppression, suppressioncarbonate, carbonatenitrite, nitritesequential, sequentialnitrate, nitratephosphate, phosphateseparation, separationsulfate, sulfatebromide
Metrosep A Supp 4 (Column manual)
Column manual Metrosep A Supp 4 (6.1006.XX0 / 6.01021.XX0) Manual 8.107.8051EN / 2017-11-30 Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com Column manual Metrosep A Supp 4 (6.1006.XX0 /…
Key words
msm, msmcolumn, columnmcs, mcseluent, eluentconductivity, conductivitysuppression, suppressioncarbonate, carbonateguard, guardsequential, sequentialseparation, separationrinse, rinsenitrite, nitritebromide, bromidefluoride, fluoridenitrate
Cation suppression in ion chromatography
Cation suppression in ion chromatography
2015|Metrohm|Brochures and specifications
Cation suppression in ion chromatography Straightforward cation analysis at trace levels Suppression in cation analysis – benefits and applications 02 Trace analysis of cations, amines, and transition metals is possible with or without suppression. However, some applications require particularly high…
Key words
suppression, suppressionmsm, msmsequential, sequentialcation, cationsuppressor, suppressorsuppres­, suppres­conductivity, conductivitystream, streamcar­, car­ultratrace, ultratracemetals, metalsregeneration, regenerationcations, cationssuppressed, suppressedeluent
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike