Metrosep A Supp 7 (Column manual)
Manuals | 2016 | MetrohmInstrumentation
Ion chromatography (IC) is a cornerstone analytical technique for the determination of inorganic anions, oxyhalides and small organic acids in environmental and industrial water samples. Its high selectivity, excellent peak symmetry and robustness enable laboratories to monitor water treatment by-products, comply with regulatory methods such as US EPA 300.1 and analyze challenging matrices from nuclear power plant coolant to biofuel blends.
This column manual aims to document the performance characteristics, operating instructions and application scope of the Metrosep A Supp 7 ion-exchange column. It provides detailed protocols for eluent preparation, column start-up, conditioning, routine use and troubleshooting, along with representative chromatograms demonstrating separation of standard anions, oxyhalides, organic acids and complex sample matrices.
The method is based on isocratic or gradient ion chromatography with suppressed conductivity detection. Key instrumentation and accessories include:
The Metrosep A Supp 7 column exhibits the following characteristics:
This IC method offers:
Emerging trends include further miniaturization of column formats, enhanced automation of inline sample preparation, integration of mass spectrometric detection, advanced suppressor technologies for lower background noise and expansion into real-time monitoring of water treatment processes and industrial effluents.
The Metrosep A Supp 7 column manual provides practitioners with comprehensive guidance on setup, operation, eluent preparation, routine use and troubleshooting for high-performance anion analysis. Its versatility and robustness support a wide range of environmental, industrial and research applications requiring reliable, reproducible results.
Consumables, Ion chromatography, LC columns
IndustriesManufacturerMetrohm
Summary
Význam tématu
Ion chromatography (IC) is a cornerstone analytical technique for the determination of inorganic anions, oxyhalides and small organic acids in environmental and industrial water samples. Its high selectivity, excellent peak symmetry and robustness enable laboratories to monitor water treatment by-products, comply with regulatory methods such as US EPA 300.1 and analyze challenging matrices from nuclear power plant coolant to biofuel blends.
Cíle a přehled studie
This column manual aims to document the performance characteristics, operating instructions and application scope of the Metrosep A Supp 7 ion-exchange column. It provides detailed protocols for eluent preparation, column start-up, conditioning, routine use and troubleshooting, along with representative chromatograms demonstrating separation of standard anions, oxyhalides, organic acids and complex sample matrices.
Použitá metodika a instrumentace
The method is based on isocratic or gradient ion chromatography with suppressed conductivity detection. Key instrumentation and accessories include:
- Metrohm ion chromatograph equipped with a high-pressure pump and MagIC Net software
- Metrosep A Supp 7 separation columns (150 or 250 mm × 4.0 mm or 2.0 mm iColumn format)
- Suppression modules (MSM, MCS or MSM-LC suppressors for sequential or chemical suppression)
- Conductivity detector
- Eluent degasser or vacuum degassing setup
- Guard columns and inline filters for particle protection
- Sample preparation modules (MISP inline ultrafiltration, matrix elimination and preconcentration cartridges)
- Pulsation absorber and PEEK capillaries for stable flow
Hlavní výsledky a diskuse
The Metrosep A Supp 7 column exhibits the following characteristics:
- Particle size: 5 µm; polymeric anion-exchange phase (quaternary ammonium on polyvinyl alcohol)
- pH working range 3–12, temperature 20–60 °C (recommended 45 °C)
- Pressure limits up to 150 bar (4 mm) or 200 bar (2 mm)
- High column efficiency and symmetrical peaks for F–, Cl–, NO2–, Br–, NO3–, SO4^2– and oxyhalides (ClO2–, BrO3–, ClO3–) plus dichloroacetic acid
- Robust performance with organic modifiers (acetonitrile, acetone, methanol) up to 30 %
- Versatile operation in isocratic carbonate/bicarbonate eluents (0–10 mmol/L) or buffered eluents, and gradient elution via Dose-in Gradient accessory
Přínosy a praktické využití metody
This IC method offers:
- Simultaneous determination of oxyhalides and standard anions in a single injection following EPA 300.1
- High throughput with short analysis times and gradient options for challenging analytes
- Minimal sample pretreatment when using inline ultrafiltration and matrix elimination
- Low environmental impact due to predominantly aqueous eluents
- Long column service life when operated with proper guard columns, eluent degassing and chemical controls
Budoucí trendy a možnosti využití
Emerging trends include further miniaturization of column formats, enhanced automation of inline sample preparation, integration of mass spectrometric detection, advanced suppressor technologies for lower background noise and expansion into real-time monitoring of water treatment processes and industrial effluents.
Závěr
The Metrosep A Supp 7 column manual provides practitioners with comprehensive guidance on setup, operation, eluent preparation, routine use and troubleshooting for high-performance anion analysis. Its versatility and robustness support a wide range of environmental, industrial and research applications requiring reliable, reproducible results.
Reference
- Application Note S-229 Oxohalides and monovalent organic acids in the presence of standard anions
- Application Note S-235 Determination of Anions and Oxohalides by US EPA method 300.1 A and B (Standard solution)
- Application Note S-236 Determination of Anions and Oxohalides by US EPA method 300.1 A and B (Sample)
- Application Note S-249 Fourteen anions in an industrial process water
- Application Note S-252 Standard anions and organic acids in Bayer liquor applying Inline Neutralization
- Application Note S-255 Sixteen anions on Metrosep A Supp 7 (250 mm) using gradient elution
- Application Note S-256 Thirteen anions on Metrosep A Supp 7 (250 mm)
- Application Note S-267 Anions in an E85 blend applying Inline Matrix Elimination
- Application Note S-277 Hexafluorosilicate besides standard anions
- Application Note S-278 Anions in sodium tetraborate with inline sample preparation
- Application Note U-48 Silicate and hexafluorosilicate
- Application Note S-305 Chlorate, thiosulfate, thiocyanate and perchlorate using Dose-in Gradient
- Application Note S-324 Trace perchlorate in drinking water
- Application Note S-327 Shorter citrate retention times using a step gradient
- Application Note S-339 Fifteen organic acids on Metrosep A Supp 7 (250 mm) with high-pressure gradient
- Poster 8.000.6071 Trace anions in PWR coolant after inline sample preparation
- The Application Notebook 2007 Simultaneous Determination of Anions and Oxy-Halides
- J. Sep. Sci. 48 (2010) Direct Injection Analysis of Bromate and Bromide in Drinking Water
- Atmos. Environ. 140 (2016) Physiochemical properties of carbonaceous aerosol
- Monograph 8.038.5003 Analysis of water samples with Metrohm instruments
- Metrohm Column Catalog 8.000.5194
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Metrosep A Supp 10 (Column manual)
2021|Metrohm|Manuals
Column manual Metrosep A Supp 10 (6.1020.XX0) Manual 8.0107.8009EN / 2021-10-08 Metrohm AG CH-9100 Herisau Switzerland +41 71 353 85 85 [email protected] www.metrohm.com Column manual Metrosep A Supp 10 (6.1020.XX0) Manual 8.0107.8009EN / 2021-10-08 Technical Communication Metrohm AG CH-9100 Herisau…
Key words
conductivity, conductivityeluent, eluentcolumn, columnmsm, msmmcs, mcsguard, guardsuppression, suppressioncarbonate, carbonatenitrite, nitritesequential, sequentialnitrate, nitratephosphate, phosphateseparation, separationsulfate, sulfatebromide
Metrosep A Supp 4 (Column manual)
2017|Metrohm|Manuals
Column manual Metrosep A Supp 4 (6.1006.XX0 / 6.01021.XX0) Manual 8.107.8051EN / 2017-11-30 Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com Column manual Metrosep A Supp 4 (6.1006.XX0 /…
Key words
msm, msmcolumn, columnmcs, mcseluent, eluentconductivity, conductivitysuppression, suppressioncarbonate, carbonateguard, guardsequential, sequentialseparation, separationrinse, rinsenitrite, nitritebromide, bromidefluoride, fluoridenitrate
Metrosep A Supp 5 (Column manual)
2017|Metrohm|Manuals
Column manual Metrosep A Supp 5 (6.1006.XX0) Manual 8.107.8040EN / 2017-04-18 Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com Column manual Metrosep A Supp 5 (6.1006.XX0) Manual 8.107.8040EN /…
Key words
column, columnmsm, msmguard, guardeluent, eluentseparation, separationsuppression, suppressionmcs, mcsconductivity, conductivitysequential, sequentialprevention, preventioncauses, causescaution, cautionrinsing, rinsingmanual, manualwater
Determination of anions in tap water using US EPA method 300
2016|Metrohm|Applications
Metrohm White Paper Determination of anions in tap water using US EPA method 300 By Hari Narayanan In this white paper, the seven common anions (fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulfate) required for US EPA method 300 Part…
Key words
msm, msmnitrate, nitrateultrafiltration, ultrafiltrationnitrite, nitritesulfate, sulfatebromide, bromidechloride, chloridefluoride, fluorideeluent, eluentanions, anionsmcl, mclmdl, mdlphosphate, phosphateregenerant, regenerantwater