Balancing sensitivity and throughput for the analysis of limited sample amounts in proteomics with ultra-low nano-flow LC-MS
Posters | 2022 | Thermo Fisher Scientific | ASMSInstrumentation
Ultra-sensitive nano-flow LC-MS is crucial for proteomic analysis of minute samples such as single cells or low-abundance protein digests. Optimizing flow rates and column dimensions can dramatically impact sensitivity and throughput to enable deep proteome coverage while processing high sample numbers.
Optimized ultra-low nano-flow LC-MS methods on standard UHPLC hardware enable exceptional sensitivity for minute samples while maintaining high throughput. Balanced flow rates (50–80 nL/min), coupled with direct-injection or trap-and-elute workflows, provide versatile solutions for deep proteome analysis of limited materials.
No additional references provided in the source text.
LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap
IndustriesProteomics
ManufacturerThermo Fisher Scientific
Summary
Importance of the topic
Ultra-sensitive nano-flow LC-MS is crucial for proteomic analysis of minute samples such as single cells or low-abundance protein digests. Optimizing flow rates and column dimensions can dramatically impact sensitivity and throughput to enable deep proteome coverage while processing high sample numbers.
Study objectives and overview
- Evaluate the impact of flow rates (40–100 nL/min) and column internal diameters (20 and 30 µm) on signal intensity and identification rates.
- Develop standardized direct-injection and trap-and-elute workflows on a Vanquish Neo UHPLC system coupled to an Orbitrap Exploris 480 for limited sample proteomics.
Methodology and equipment
- Sample: HeLa protein digest (1–5 ng) prepared in 0.1% formic acid.
- UHPLC: Thermo Scientific Vanquish Neo system.
- Mass spectrometer: Thermo Scientific Orbitrap Exploris 480 operating in DDA mode.
- Columns: Direct injection on PepMap Neo (20 µm × 150 mm) or trap-and-elute with PepMap trap (30 µm × 2 mm) and analytical column (20 µm × 250 mm).
- Solvents: A = water/0.1% formic acid; B = 80% acetonitrile/20% water/0.1% formic acid.
- Data analysis: Proteome Discoverer 2.5 with Sequest HT and INFERYS rescoring, FDR <1%.
Key results and discussion
- Ultra-low nano-flow (50–80 nL/min) achieved up to 10× sensitivity compared with 300 nL/min, enabling identification of >2000 proteins from 5 ng HeLa digest in a single shot.
- Trap-and-elute workflow reduced cycle times to 20 min (72 samples/day) while maintaining high MS utilization and identification rates (>200 proteins from 200 pg digest).
- Optimal gradient lengths varied with sample load; steeper gradients improved sensitivity at sub-ng levels by preserving peak height.
- Flow-rate increase beyond 80 nL/min improved throughput but incurred peak broadening, limiting additional gains in identifications.
Advantages and practical applications
- Flexible workflows for both maximum sensitivity (direct injection) and high throughput (trap-and-elute).
- Standard hardware setup without specialized nano-LC modifications simplifies method adoption.
- Enables deep proteomic profiling of limited samples, single cells, or rare clinical specimens.
- Supports high-throughput studies, including multiplexed quantitative experiments (e.g., TMT), up to ~1000 single cells/day.
Future trends and applications
- Further miniaturization of column IDs and integration of microfluidics could push sensitivity limits below 100 pg.
- Advanced acquisition strategies (e.g., DIA, advanced scan modes) combined with optimized low-flow LC may improve reproducibility and proteome depth.
- Integration with single-cell isolation platforms will support high-content proteomics in clinical and translational research.
- Automation and multiplexing enhancements could increase daily sample throughput beyond current limits.
Conclusion
Optimized ultra-low nano-flow LC-MS methods on standard UHPLC hardware enable exceptional sensitivity for minute samples while maintaining high throughput. Balanced flow rates (50–80 nL/min), coupled with direct-injection or trap-and-elute workflows, provide versatile solutions for deep proteome analysis of limited materials.
References
No additional references provided in the source text.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Getting started with μPAC Neo HPLC columns
2023|Thermo Fisher Scientific|Technical notes
Start-up guide | 001891 HPLC columns Getting started with µPAC Neo HPLC columns Goal Improved performance To provide a comprehensive guide for the installation of the Complementary to the first-generation micro-pillar array HPLC Thermo Scientific™ µPAC™ Neo HPLC Columns on…
Key words
µpac, µpacneo, neocolumn, columnmin, mintrap, traploading, loadingequilibration, equilibrationwash, washduration, durationflow, flowpsms, psmsgroups, groupsphase, phasevolume, volumepressurecontrol
A high-sensitivity high-throughput LCMS platform for single-cell proteomics and low sample amount analysis
|Thermo Fisher Scientific|Posters
A high-sensitivity high-throughput LCMS platform for single-cell proteomics and low sample amount analysis Runsheng Zheng1, Christopher Pynn1, Manuel Matzinger2, Karl Mechtler2, Alexander Makarov3, Wim Decrop1, Alec Valenta1, Martin Samonig1 1Thermo Fisher Scientific, Germering, Germany; 2Institute of Molecular Pathology, Vienna, Austria;…
Key words
throughput, throughputlcms, lcmsdda, ddanano, nanosensitivity, sensitivitylsa, lsathermo, thermohigh, highgradient, gradientscp, scplow, lowlength, lengthlfq, lfqproteomics, proteomicsscientific
Thermo Scientific Vanquish Neo UHPLC system
2021|Thermo Fisher Scientific|Brochures and specifications
Vanquish Neo UHPLC System Beyond brilliant 2 The new standard in nano-, capillary-, and micro-flow LC For researchers pursuing the next scientific breakthrough, the Thermo Scientific™ Vanquish™ Neo UHPLC system offers the highest performance, productivity, and usability of any nano-,…
Key words
vanquish, vanquishneo, neoscientific, scientificthermo, thermouhplc, uhplcsystem, systemflow, flownanoviper, nanoviperloading, loadingnano, nanoinjection, injectionequilibration, equilibrationdirect, directtrap, traplow
Balancing sensitivity and throughput in single-cell proteomics using low-nanoflow LC-MS
2025|Thermo Fisher Scientific|Posters
Proteomics Balancing sensitivity and throughput in single-cell proteomics using low-nanoflow LC-MS Runsheng Zheng1; Manuel Matzinger2; Rupert Mayer2; Alec Valenta1; Tabiwang N Arrey3; Xuefei Sun4; Christopher Pynn1; Ece Aydin1; Wim Decrop1; Dominic Hoch5; Martin Samonig1; Karl Mechtler2 1Thermo Fisher Scientific, Germering,…
Key words