Quality Control of Synthetic Peptides using the MALDI-8030 Dual Polarity Benchtop MALDI-TOF Mass Spectromete

Applications | 2022 | ShimadzuInstrumentation
MALDI, LC/TOF, LC/MS
Industries
Proteomics
Manufacturer
Shimadzu

Summary

Significance of the Topic


The quality control of synthetic peptides is crucial for ensuring their purity and correct structure in applications such as diagnostics, therapeutics, vaccine design, and fundamental research. MALDI-TOF mass spectrometry offers rapid confirmation of peptide identity and purity, and exploring negative ion mode enhances the detection of labile modifications and reduces spectral complexity caused by salt adducts.

Objectives and Study Overview


This study evaluates the performance of the MALDI-8030 dual polarity benchtop linear MALDI-TOF mass spectrometer for quality control analysis of synthetic peptides. It aims to compare positive and negative ion modes in terms of:
  • Preservation of labile functional groups
  • Simplification of spectral interpretation

Methodology and Used Instrumentation


Samples:
  • Peptide D containing two sulfo groups on tyrosines
  • Peptide A in semi-pure and pure forms
Preparation: peptides dissolved in 1:1 acetonitrile/water with or without 0.1% TFA, mixed with CHCA matrix at 5 mg/mL. Instrumentation: Shimadzu MALDI-8030 dual polarity benchtop linear MALDI-TOF mass spectrometer, operated in both positive and negative ion modes.

Main Results and Discussion


  • Peptide D: Positive mode caused loss of sulfo groups, detecting only de-sulfated species. Negative mode retained both sulfo groups and detected the intact peptide with high mass accuracy and clear isotopic resolution.
  • Peptide A (semi-pure and pure): Positive mode spectra exhibited multiple sodium and potassium adducts of impurities and target peptide, complicating analysis. Negative mode significantly reduced salt adduct signals, yielding cleaner spectra and straightforward identification of the peptide.

Benefits and Practical Applications


The negative ion mode on the MALDI-8030 enables:
  • Detection of peptides with labile modifications without fragmentation
  • Reduction of salt adduct interferences for clearer spectra
  • Efficient and affordable benchtop QC solution for peptide synthesis workflows

Future Trends and Potential Applications


Expanding negative ion MALDI-TOF QC to a broader range of post-translationally modified peptides, integrating automated sample preparation and high-throughput screening. Coupling with advanced data analysis, including machine learning algorithms, could further enhance rapid peptide characterization in pharmaceutical and biotechnological industries.

Conclusion


The study demonstrates that negative ion mode MALDI-TOF analysis on the MALDI-8030 significantly improves the quality control of synthetic peptides by preserving labile groups and simplifying spectra, offering a cost-effective and robust tool for research and industrial laboratories.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Quality Control of Synthetic Peptides using the MALDI-8030 Dual Polarity Benchtop MALDI-TOF Mass Spectrometer
MALDI-TOF Mass Spectrometry Analysis Application News MALDI-8030 Quality Control of Synthetic Peptides using the MALDI-8030 Dual Polarity Benchtop MALDI-TOF Mass Spectrometer S. Salivo User Benefits  Easy, simple, negative ion quality control of peptides on affordable benchtop MALDI-TOF  Useful…
Key words
intensity, intensitypeptide, peptidenegative, negativemode, modeadducts, adductsadduct, adductsalt, saltpeptides, peptidescalculated, calculatedpure, pureimpurity, impuritysynthetic, syntheticpositive, positivenews, newspotassium
Negative Mode Analysis of Synthetic Oligonucleotides using the MALDI-8030 Dual Polarity Benchtop MALDI-TOF Mass Spectromet
MALDI-TOF Mass Spectrometry Analysis Application News MALDI-8030 Negative Mode Analysis of Synthetic Oligonucleotides using the MALDI-8030 Dual Polarity Benchtop MALDI-TOF Mass Spectrometer S. Salivo (KRATOS ANALYTICAL LTD.) User Benefits  Simple analysis of oligonucleotides, in negative ion mode to reduce…
Key words
cftr, cftrprimer, primerethidium, ethidiumhomozygote, homozygoteallele, allelewild, wildheterozygote, heterozygotenegative, negativegene, geneoligonucleotides, oligonucleotidesmode, modepcr, pcrgel, gelnormal, normalelectrophoresis
Negative Mode Analysis of Synthetic Oligonucleotides using the MALDI-8030 Dual Polarity Benchtop MALDI-TOF Mass Spectrometer
MALDI-TOF Mass Spectrometry Analysis Application News MALDI-8030 Negative Mode Analysis of Synthetic Oligonucleotides using the MALDI-8030 Dual Polarity Benchtop MALDI-TOF Mass Spectrometer S. Salivo User Benefits  Simple analysis of oligonucleotides, in negative ion mode to reduce adducts, on an…
Key words
cftr, cftrprimer, primerethidium, ethidiumhomozygote, homozygoteallele, allelewild, wildheterozygote, heterozygotenegative, negativegene, geneoligonucleotides, oligonucleotidesmode, modepcr, pcrgel, gelnormal, normalelectrophoresis
Dual-Polarity Benchtop Linear MALDI-TOF Mass Spectrometer - MALDI-8030
MO473 Dual-Polarity Benchtop Linear MALDI-TOF Mass Spectrometer MALDI-8030 AFFORDABLE CLASSBest-in-class sensitivity and resolution • Easily detect analytes for your application Award-winning design • Based on the award-winning MALDI-8020 design Innovative electronics • Fast, high bit-depth transient recorder provides rapid data…
Key words
intensity, intensitymaldi, malditrueclean, truecleanevoo, evoolaser, laserdual, dualpolarity, polarityyour, yourbenchtop, benchtopaurasolution, aurasolutionintact, intactfleximass, fleximassmass, massmisidentification, misidentificationemstat
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike