The Agilent Cary 60 eliminates photodegradation of aromatic markers used in UV-Vis spectrophotometric applications
Applications | 2011 | Agilent TechnologiesInstrumentation
The stability of colorimetric markers under light exposure is critical for reliable UV-Vis spectrophotometry, particularly when measuring sensitive compounds such as aromatic heterocycles. Photobleaching can compromise quantitative results and limit applications in biochemical assays, environmental monitoring, and material sciences. The Agilent Cary 60 addresses these challenges by employing a xenon flash lamp design that minimizes sample irradiation and preserves spectral integrity.
This study evaluates the Agilent Cary 60 UV-Vis spectrophotometer's ability to prevent photodegradation of tricyclic heteroaromatic compounds, using methylene blue as a model marker. The work aims to replicate and extend previous findings by comparing continuous scanning and kinetics measurements over extended exposure times.
Apparatus and reagents:
Experimental procedure:
Ten overlaid spectral scans exhibited perfect overlap with no loss in absorbance, confirming both instrumental accuracy and the absence of photobleaching. Kinetic data at 664 nm showed stable absorbance over 20 minutes of continuous measurement, in contrast to significant bleaching reported for conventional UV-Vis systems. The xenon flash lamp's low-duty-cycle illumination is the key factor in eliminating sample degradation.
The Cary 60 enables precise analysis of photosensitive compounds in research and quality-control settings. Applications include transient kinetics studies, DNA binding experiments, environmental contaminant monitoring, and routine spectral assays where photostability is essential.
Advances may include integration of flash-lamp spectrophotometry with microfluidic platforms for high-throughput analysis, expanded use in photodynamic therapy research, portable field instruments with low photodegradation risk, and coupling with chemometric analysis for real-time monitoring of reaction kinetics.
The Agilent Cary 60 UV-Vis spectrophotometer's patented xenon flash lamp design effectively prevents photobleaching of aromatic markers, ensuring accurate, reproducible results for sensitive samples. This innovation broadens the scope of UV-Vis applications where light-induced sample alteration has previously been a limiting factor.
UV–VIS spectrophotometry
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies
Summary
Significance of the Topic
The stability of colorimetric markers under light exposure is critical for reliable UV-Vis spectrophotometry, particularly when measuring sensitive compounds such as aromatic heterocycles. Photobleaching can compromise quantitative results and limit applications in biochemical assays, environmental monitoring, and material sciences. The Agilent Cary 60 addresses these challenges by employing a xenon flash lamp design that minimizes sample irradiation and preserves spectral integrity.
Study Objectives and Overview
This study evaluates the Agilent Cary 60 UV-Vis spectrophotometer's ability to prevent photodegradation of tricyclic heteroaromatic compounds, using methylene blue as a model marker. The work aims to replicate and extend previous findings by comparing continuous scanning and kinetics measurements over extended exposure times.
Methodology and Instrumentation
Apparatus and reagents:
- Agilent Cary 60 UV-Vis spectrophotometer (Part G6860AA) with WinUV software
- Xenon flash lamp optical design
- Methylene blue solution (20 ppm) in purified water
- Disposable quartz cuvettes (3 mL volume)
Experimental procedure:
- Recorded baseline with purified water.
- Performed ten superimposed scans to determine the maximum absorbance wavelength and assess reproducibility.
- Set kinetics measurements at the peak wavelength (664 nm) with readings every 12.5 ms over 20 minutes.
Main Results and Discussion
Ten overlaid spectral scans exhibited perfect overlap with no loss in absorbance, confirming both instrumental accuracy and the absence of photobleaching. Kinetic data at 664 nm showed stable absorbance over 20 minutes of continuous measurement, in contrast to significant bleaching reported for conventional UV-Vis systems. The xenon flash lamp's low-duty-cycle illumination is the key factor in eliminating sample degradation.
Practical Benefits and Applications
The Cary 60 enables precise analysis of photosensitive compounds in research and quality-control settings. Applications include transient kinetics studies, DNA binding experiments, environmental contaminant monitoring, and routine spectral assays where photostability is essential.
Future Trends and Applications
Advances may include integration of flash-lamp spectrophotometry with microfluidic platforms for high-throughput analysis, expanded use in photodynamic therapy research, portable field instruments with low photodegradation risk, and coupling with chemometric analysis for real-time monitoring of reaction kinetics.
Conclusion
The Agilent Cary 60 UV-Vis spectrophotometer's patented xenon flash lamp design effectively prevents photobleaching of aromatic markers, ensuring accurate, reproducible results for sensitive samples. This innovation broadens the scope of UV-Vis applications where light-induced sample alteration has previously been a limiting factor.
References
- Kok C. et al. Study of Photobleaching Mechanism in Methylene Blue Sensitized Gelatin Using a Single Beam UV-Vis Fiber Optics Spectrophotometer. Pertanika J. Sci. & Technol. 2005;13(1):23–30.
- Fujimoto A. et al. Fluorescence and Photobleaching Studies of Methylene Blue Binding to DNA. J. Phys. Chem. 1994;98:6633–6643.
- Comerford J. Investigations of Photochemical Reactions using UV/VIS Spectroscopy. Application UV-76; February 1998.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Simple, automated measurements of the photocatalytic properties of colorimetric species using the Agilent Cary 60 UV-Vis spectrophotometer with fiber optics
2011|Agilent Technologies|Applications
Simple, automated measurements of the photocatalytic properties of colorimetric species using the Agilent Cary 60 UV-Vis spectrophotometer with fiber optics Application Note Chemicals Author Summary *Fyfe, DJ and **Wang, XD The Agilent Cary 60 UV-Vis spectrophotometer is the new, improved…
Key words
blue, bluemethylene, methylenefiber, fibermicroprobe, microprobeoptics, opticsphotobleaching, photobleachingphotodegradation, photodegradationcoupler, coupleroptic, opticsitu, situphotokinetic, photokineticdiscussed, discussedintensity, intensityaccessory, accessorytemplating
Enhance Your Capabilities with the Agilent Cary 60 UV-Vis Spectrophotometer and Fiber Optic Probes
2025|Agilent Technologies|Brochures and specifications
Enhance Your Capabilities with the Agilent Cary 60 UV-Vis Spectrophotometer and Fiber Optic Probes Improve your lab operations Remote capabilities with fiber optic probes The Agilent Cary 60 UV-Vis spectrophotometer can be paired with fiber optic probes to unlock the…
Key words
optic, opticfiber, fiberprobes, probesremote, remoteabsorbance, absorbanceprobe, probeabs, absspectrophotometer, spectrophotometermeasurements, measurementsimprove, improveoperations, operationsvis, visyour, yourspectroscopy, spectroscopyhoods
Minimizing photobleaching of Blue Fluorescent Protein (BFP) using the Agilent Cary Eclipse fluorescence spectrophotometer
2011|Agilent Technologies|Applications
Minimizing photobleaching of Blue Fluorescent Protein (BFP) using the Agilent Cary Eclipse fluorescence spectrophotometer Application Note Author Introduction Paul Gavin*, Mark Prescott*, Ph.D, Daren J. Fyfe, Ph.D and Jeffrey J. Comerford**, Ph.D The term photobleaching refers to loss of fluorescence…
Key words
cary, carybfp, bfpfluorescence, fluorescenceeclipse, eclipsephotobleaching, photobleachingspectrophotometer, spectrophotometerxenon, xenonexcitation, excitationmulticell, multicellpeltier, peltierthermostatted, thermostattedfluorescent, fluorescentyeast, yeastfluorophore, fluorophoreholder
SPANDS Colorimetric Method to Quantify Fluorides in Water
2023|Agilent Technologies|Applications
Application Note Environmental SPANDS Colorimetric Method to Quantify Fluorides in Water Convenient and precise concentration measurements with the Agilent Cary 60 UV-Vis spectrophotometer Authors Rogelio García and Geethika Weragoda Agilent Technologies, Inc. Abstract The Agilent Cary 60 UV-Vis spectrophotometer was…
Key words
fluoride, fluoridespands, spandscary, carywinuv, winuvfluorides, fluoridescolorimetric, colorimetricwater, watermethod, methodwavelength, wavelengthabsorbance, absorbancesoftware, softwarequantification, quantificationmodule, moduleagilent, agilentcurve