Importance of the topic


Ion chromatography is a cornerstone technique in environmental and water analysis, allowing precise determination of inorganic anions at trace levels. Accurate quantification of species such as fluoride, nitrate and sulfate is essential for regulatory compliance, pollution monitoring and safeguarding public health.

Objectives and study overview


This application note presents a robust method for simultaneous separation and detection of nine common anions using Shimadzu’s Shim-pack IC-SA2 column. The goal is to demonstrate resolution, sensitivity, and runtime efficiency for routine quality control and environmental laboratories.

Methodology


An isocratic suppressed conductivity ion chromatography approach was adopted. A carbonate/bicarbonate mobile phase enables effective elution of both monovalent and multivalent anions. Suppression reduces background conductivity, improving signal-to-noise ratios.

Used instrumentation


  • IC system: Prominence HIC-SP
  • Analytical column: Shim-pack IC-SA2 (250 mm × 4.0 mm I.D., 9 µm)
  • Mobile phase: 12 mmol/L NaHCO₃ and 0.6 mmol/L Na₂CO₃
  • Flow rate: 1.0 mL/min
  • Column temperature: 30 °C
  • Injection volume: 50 µL
  • Detector: Suppressed conductivity (CDD-10Avp)

Main results and discussion


The method achieved baseline separation of nine anions—including fluoride, acetate, formate, chloride, nitrite, bromide, nitrate, phosphate and sulfate—within 18 minutes. Resolution exceeded regulatory requirements, and repeatability was better than 1 % RSD for retention times and peak areas. Sensitivity permitted detection limits below 0.1 mg/L for most analytes.

Benefits and practical application


• Rapid, high-throughput analysis ideal for routine water quality testing
• Low background noise and high sensitivity via suppressor technology
• Robust performance under isocratic conditions simplifies method maintenance
• Applicability to environmental monitoring, drinking water certification and industrial process control

Future trends and possibilities of use


Emerging developments include coupling ion chromatography with mass spectrometry for enhanced selectivity, miniaturized high-pressure systems for field deployable analysis, and the use of greener mobile phases. Automated calibration and data interpretation using AI-driven software promise to further streamline workflows.

Conclusion


The Shim-pack IC-SA2 combined with the Prominence HIC-SP system delivers reliable, efficient separation and quantification of key inorganic anions. Its reproducibility, sensitivity and moderate runtime make it a valuable tool for both environmental laboratories and industrial quality assurance.

References


  1. Shimadzu Corporation. ERAS-1000-0379: Ion Chromatography (IC) Shim-pack Series, First Edition, October 2022.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Analysis of Iodate Ion and Iodide Ion
Analysis of Iodate Ion and Iodide Ion
2022|Shimadzu|Applications
ERAS-1000-0368 Ion Chromatography (IC) Shim-pack Series Shim-packTM IC-SA2 Analysis of Iodate Ion and Iodide Ion 368 Keywords: Halogen mAU 22.5 20.0 210 nm 225 nm 2 17.5 1. Iodate ion (IO3-) (20 mg/L) 2. Iodide ion (I-) (14.5 mg/L) 15.0…
Key words
prominencetm, prominencetmiodate, iodateion, ionhic, hiciodide, iodideshim, shimpack, packguard, guardmau, maucolumn, columnseries, seriesmobile, mobilerate, ratephase, phasechromatography
Analysis of Anions by Ion Chromatography
ERAS-1000-0208 Ion Chromatography (IC) Shim-pack Series Shim-packTM IC-SA2 Analysis of Anions by Ion Chromatography 208 Keywords: fluoride, chloride, bromide, nitrate, nitrite, phosphate, sulfate µS/cm 5.0 3 1. F2. Cl3. NO24. Br5. NO36. PO437. SO42- 1 4.0 3.0 4 5 6…
Key words
anions, anionsshim, shimpack, packion, ionguard, guardchromatography, chromatographyvial, vialcolumn, columnseries, seriesmobile, mobilevolume, volumerate, ratephase, phaseinjection, injectiondetection
Analysis of Chloride ion and sulfate ion in chondroitin sulfate
ERAS-1000-0441 Ion Chromatography (IC) Shim-pack Series Shim-packTM IC-SA2, Analysis of Chloride ion and sulfate ion in chondroitin sulfate 441 Keywords: counter ion analysis, Japanese Pharmacopeia, suppressor ion chromatogram, anion analysis 1. Cl2. SO42- Column : Shim-pack IC-SA2, (250 mm L…
Key words
sulfate, sulfatechondroitin, chondroitinion, ionshim, shimpack, packguard, guardchloride, chloridevial, vialcolumn, columnseries, seriesmobile, mobilerate, ratephase, phasechromatography, chromatographydetection
Analysis of Chloride and Sulfate Ions in Fuel Ethanol - No. 446
ERAS-1000-0446 Ion Chromatography (IC) Shim-pack Series Shim-packTM IC-C4 Analysis of Chloride and Sulfate Ions in Fuel Ethanol 446 Keywords: ASTM D7319-07, suppressor ion chromatograph, alternative fuel 1. Cl2. SO42- System Column : : Guard Column : Mobile Phase : Flow…
Key words
esp, esphic, hicfuel, fuelshim, shimpack, packethanol, ethanolguard, guardsulfate, sulfateconductivity, conductivitychloride, chloridevial, vialcolumn, columnseries, seriesions, ionsmobile
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike