874 Oven Sample Processor
Others | | MetrohmInstrumentation
The accurate determination of water content in samples is essential across pharmaceutical, chemical and food industries. The 874 Oven Sample Processor automates thermal pre-treatment, enabling precise release of bound or sparingly soluble water that is otherwise inaccessible at ambient conditions.
The 874 Oven Sample Processor (Order no. 2.874.0120) is designed to streamline Karl Fischer titration workflows by automating sample heating and transfer. Its scope of delivery provides all necessary components for a fully sealed system, while a range of optional accessories extends its versatility for diverse analytical applications.
The oven method heats samples to elevated temperatures, ensuring complete liberation of water which is then carried into the titration cell by a dry gas stream. Key delivered items include:
The processor offers programmable temperature control, efficient gas-tight sample transfer and compatibility with Metrohm KF titrators. Optional modules such as the 800 Dosino, additional Titrandos and stirrers allow integration of dosing and agitation steps. The system supports trace-level detection (µg range) and high throughput by accommodating up to 36 samples per run.
Emerging developments may include integration with laboratory information management systems (LIMS) and advanced analytics platforms. Future enhancements could feature inert gas operation, higher temperature capabilities and robotic sample loading for fully unattended workflows.
The 874 Oven Sample Processor delivers reliable, automated thermal sample preparation for Karl Fischer titration, addressing the needs of modern analytical laboratories for precision, efficiency and versatility.
Titration Karl Fischer
IndustriesManufacturerMetrohm
Summary
Significance of the Topic
The accurate determination of water content in samples is essential across pharmaceutical, chemical and food industries. The 874 Oven Sample Processor automates thermal pre-treatment, enabling precise release of bound or sparingly soluble water that is otherwise inaccessible at ambient conditions.
Objectives and Product Overview
The 874 Oven Sample Processor (Order no. 2.874.0120) is designed to streamline Karl Fischer titration workflows by automating sample heating and transfer. Its scope of delivery provides all necessary components for a fully sealed system, while a range of optional accessories extends its versatility for diverse analytical applications.
Methodology and Instrumentation
The oven method heats samples to elevated temperatures, ensuring complete liberation of water which is then carried into the titration cell by a dry gas stream. Key delivered items include:
- Heating tube stopper for coulometric KF vessels
- Drying bottle (100 mL) with GL 45 screw cap and matching filter tube
- FEP tubing (multiple lengths) with light and kink protection
- Sample rack for 36×6 mL vials
- Needle holders with Luer lock
- USB A–mini-DIN 8-pin controller cable
Main Features and Discussion
The processor offers programmable temperature control, efficient gas-tight sample transfer and compatibility with Metrohm KF titrators. Optional modules such as the 800 Dosino, additional Titrandos and stirrers allow integration of dosing and agitation steps. The system supports trace-level detection (µg range) and high throughput by accommodating up to 36 samples per run.
Benefits and Practical Applications
- Improved reproducibility for samples releasing water only at elevated temperatures
- Reduced manual handling and risk of contamination through full automation
- Adaptable to a wide variety of matrices, including solids, viscous liquids and polymers
Future Trends and Potential Applications
Emerging developments may include integration with laboratory information management systems (LIMS) and advanced analytics platforms. Future enhancements could feature inert gas operation, higher temperature capabilities and robotic sample loading for fully unattended workflows.
Conclusion
The 874 Oven Sample Processor delivers reliable, automated thermal sample preparation for Karl Fischer titration, addressing the needs of modern analytical laboratories for precision, efficiency and versatility.
Used Instrumentation
- 874 Oven Sample Processor (2.874.0120)
- Heating tube stopper (6.1446.170)
- Drying flask cap (6.1602.145) and drying bottle 100 mL (6.1608.050)
- FEP tubing (6.1805.010; 6.1805.050; 6.1805.470)
- Thread and tubing adapters (6.1808.040; 6.1808.050)
- Filter tube (6.1821.040)
- Sample rack, 36×6 mL (6.2041.720)
- Needle holders with Luer lock (6.2049.040; 6.2049.050)
- USB A–mini-DIN 8-pin cable (6.2151.000)
- Safety shield (6.2751.140)
- Molecular sieve, 250 g (6.2811.000)
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
874 Oven Sample Processor special vials
|Metrohm|Others
874 Oven Sample Processor special vials 2.874.0130 Below, the accessories are grouped into Scope of delivery and Optional accessories. Please keep this printout at hand for ordering replacement material. These lists may be subject to change. Scope of delivery 2.874.0130…
Key words
metrohm, metrohmcoulometry, coulometrycoulometric, coulometrickink, kinkcable, cableideal, idealwater, watertitrations, titrationscontent, contentclip, clipdetermination, determinationcoulometer, coulometerprotection, protectionheatable, heatableclamping
860 KF Thermoprep
|Metrohm|Others
860 KF Thermoprep 2.860.0010 Below, the accessories are grouped into Scope of delivery and Optional accessories. Please keep this printout at hand for ordering replacement material. These lists may be subject to change. Scope of delivery 2.860.0010 Qt. Order no.…
Key words
metrohm, metrohmneedle, needleholder, holderkink, kinktongs, tongsheatable, heatabletubing, tubingheating, heatingconnection, connectioncrimping, crimpingpiercing, piercingfilter, filtertube, tubecoulometric, coulometricstopper
852 Titrando
2020|Metrohm|Manuals
852 Titrando Manual 8.852.8003EN / 2020-08-10 Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com 852 Titrando Manual 8.852.8003EN / 2020-08-10 Technical Communication Metrohm AG CH-9100 Herisau [email protected] This documentation…
Key words
titration, titrationelectrode, electrodeconnecting, connectingcoulometer, coulometerpolarization, polarizationdosing, dosingtouch, touchremote, remotegenerator, generatormsb, msbkarl, karlcable, cablecell, cellfischer, fischeripol
851 Titrando
2020|Metrohm|Brochures and specifications
851 Titrando Manual 8.851.8004EN / 2020-08-10 Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com 851 Titrando Manual 8.851.8004EN / 2020-08-10 Technical Communication Metrohm AG CH-9100 Herisau [email protected] This documentation…
Key words
connecting, connectingelectrode, electrodecoulometer, coulometertitration, titrationtouch, touchdosing, dosingremote, remotemsb, msbgenerator, generatorcell, cellcable, cablewarning, warningusb, usbnotice, noticepower