Choosing the appropriate cation-exchange column for quaternary amine determinations
Applications | 2022 | Thermo Fisher ScientificInstrumentation
The analysis of quaternary ammonium compounds is critical across industrial agriculture and pharmaceutical fields due to their ubiquity and potential health and environmental risks Among these compounds are naturally occurring and synthetic species that require reliable quantitation for safety and regulatory compliance
This study evaluated four cation exchange chromatography columns for the separation and detection of ten quaternary ammonium analytes A reagent free ion chromatography platform generating methanesulfonic acid eluent was employed with suppressed conductivity detection Comparisons were based on retention time peak asymmetry and column efficiency under isocratic conditions at two analyte concentrations
Ultrapure water was used to prepare stock amine solutions that were diluted to intermediate and working standards The samples were maintained at four degrees Celsius until analysis
Retention times for early eluting analytes were consistent across columns within half a minute Late eluters showed differences up to one and a half minutes Comparative assessment of peak asymmetry and efficiency revealed that the CS17 and CS21-4 µm columns delivered superior peak shapes and higher theoretical plate counts The smaller particle size of the CS21 column accounts for its enhanced efficiency while the CS17 column maintains better symmetry for late eluting herbicide analytes Column selection guidelines were developed based on typical application requirements
Integration with tandem mass spectrometry is expected to expand specificity for trace level determinations Continued development of high efficiency stationary phases and miniaturized formats will address evolving analytical challenges Continuous method refinement will support monitoring of emerging quaternary ammonium species and their environmental fate
Comparative evaluation of four cation exchange columns identified the CS21-4 µm column as the preferred choice for most quaternary ammonium analyses due to its outstanding efficiency The CS17 column remains a viable alternative when separation of late eluting herbicide analytes is not required Column selection should be guided by the target compound set and key performance metrics such as peak symmetry and theoretical plate count
Consumables, Ion chromatography, LC columns
IndustriesEnvironmental
ManufacturerThermo Fisher Scientific
Summary
Significance of the Topic
The analysis of quaternary ammonium compounds is critical across industrial agriculture and pharmaceutical fields due to their ubiquity and potential health and environmental risks Among these compounds are naturally occurring and synthetic species that require reliable quantitation for safety and regulatory compliance
Study Objectives and Overview
This study evaluated four cation exchange chromatography columns for the separation and detection of ten quaternary ammonium analytes A reagent free ion chromatography platform generating methanesulfonic acid eluent was employed with suppressed conductivity detection Comparisons were based on retention time peak asymmetry and column efficiency under isocratic conditions at two analyte concentrations
Methodology and Instrumentation
Ultrapure water was used to prepare stock amine solutions that were diluted to intermediate and working standards The samples were maintained at four degrees Celsius until analysis
- Ion chromatography system comprising a dual pump degas unit detector compartment and cooled autosampler
- Electrogenerated methanesulfonic acid eluent produced by a reagent free cartridge
- Continuously regenerated suppressor for conductivity detection
- Evaluation of four cation exchange columns namely CS17 CS19-4 µm CS20 and CS21-4 µm with matched guard columns
- Operating parameters included a flow rate of 0.3 mL/min column temperature of 40 °C and injection volumes of 2.5 to 5 µL
Results and Discussion
Retention times for early eluting analytes were consistent across columns within half a minute Late eluters showed differences up to one and a half minutes Comparative assessment of peak asymmetry and efficiency revealed that the CS17 and CS21-4 µm columns delivered superior peak shapes and higher theoretical plate counts The smaller particle size of the CS21 column accounts for its enhanced efficiency while the CS17 column maintains better symmetry for late eluting herbicide analytes Column selection guidelines were developed based on typical application requirements
Advantages and Practical Applications
- Enhanced column efficiency leads to greater sensitivity and resolution
- Improved peak shapes simplify quantitation in complex matrices
- Multiple column options allow tailoring to target analyte profiles and regulatory needs
- Reagent free eluent generation streamlines operation and reduces maintenance
Future Trends and Applications
Integration with tandem mass spectrometry is expected to expand specificity for trace level determinations Continued development of high efficiency stationary phases and miniaturized formats will address evolving analytical challenges Continuous method refinement will support monitoring of emerging quaternary ammonium species and their environmental fate
Conclusion
Comparative evaluation of four cation exchange columns identified the CS21-4 µm column as the preferred choice for most quaternary ammonium analyses due to its outstanding efficiency The CS17 column remains a viable alternative when separation of late eluting herbicide analytes is not required Column selection should be guided by the target compound set and key performance metrics such as peak symmetry and theoretical plate count
References
- Mulder I Siemens J Sentek V et al Quaternary ammonium compounds in soil implications for antibiotic resistance development Reviews in Environmental Science and Biotechnology 2018 17 159 185
- Thermo Fisher Scientific Determination of bethanechol by ion chromatography Application Note 148
- Sterk PJ Fabbri LM Quanjer PH et al Airway responsiveness standardized challenge testing with pharmacological physical and sensitizing stimuli in adults European Respiratory Journal 1993 6 Suppl 16 53 83
- Thermo Fisher Scientific Determination of cationic polar pesticides in homogenized fruit and vegetable samples using IC HRAM MS Application Note 72908
- United States Environmental Protection Agency US EPA Pesticide Chemical Search database Accessed 2022
- US EPA Ecological Fate and Effects Division of the USEPA Office of Pesticide Programs OPP Pesticide Ecotoxicity Database
- EU Commission Pesticide Residue Database MRL Accessed 2022
- CDC Facts About Paraquat Emergency Response Accessed 2022
- Esparza X Moyano E Galceran MT Analysis of chlormequat and mepiquat by hydrophilic interaction chromatography coupled to tandem mass spectrometry Journal of Chromatography A 2009 1216 4402 4406
- Boethling R Environmental fate and toxicity in wastewater treatment of quaternary ammonium surfactants Water Research 1984 18 1061 1076
- Levsen K Emmrich M Behnert S Determination of dialkyldimethylammonium compounds and other cationic surfactants in sewage water and activated sludge Fresenius Journal of Analytical Chemistry 1993 346 732 737
- Thermo Fisher Scientific Determination of methacholine chloride and potential impurities using a reagent free ion chromatography system Application Note 249
- Thermo Fisher Scientific Validation of an improved ion chromatography method for the limit of choline test in the USP Succinylcholine Chloride monograph Application Note 72649
- Thermo Fisher Scientific Determination of carbachol in ophthalmic solutions using a reagent free ion chromatography system Application Note 194
- Thermo Fisher Scientific Determination of cationic polar pesticides in oat cereals by ion chromatography and electrospray ionization mass spectrometry Application Note 1166
- Pizzutti IR Vela GM de Kok A Scholten JM Dias JV Cardoso CD Concenço G Vivian R Determination of paraquat and diquat LC MS method optimization and validation Food Chemistry 2016 209 248 255
- Thermo Fisher Scientific Determination of four quaternary ammonium polar pesticides in food and beverage samples by tandem IC MS MS Application Note 73990
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Evaluation of cationic quaternary amines by ion chromatography and mass spectroscopy (IC-MS)
2023|Thermo Fisher Scientific|Applications
Technical note | 001900 Food safety Evaluation of cationic quaternary amines by ion chromatography and mass spectroscopy (IC-MS) Authors Goal Terri Christison, John E. Madden, Demonstrate the suitability of select quaternary amines for IC-MS analysis using a and Jeff Rohrer…
Key words
dionex, dionexminutes, minutessuppressed, suppressedmass, masssim, simconductivity, conductivitymsa, msaisq, isqthermo, thermoscientific, scientificsuppressor, suppressorspectrometry, spectrometrycounts, countspesticides, pesticidesdimethylhydrazine
Ion Chromatography Mass Spectrometry methods for cationic polar pesticides analysis
2022|Thermo Fisher Scientific|Posters
Ion Chromatography Mass Spectrometry methods for cationic polar pesticides analysis John E. Madden, Anna Blank, Charanjit Saini, Yan Liu, Alexandra Zatirakha Thermo Fisher Scientific, 1228 Titan Way, Sunnyvale, CA, USA, 94085 Evaluation of target analytes Abstract The hyphenation of Ion…
Key words
yes, yesquantifier, quantifiergood, goodpoor, poorexcellent, excellenttriazole, triazolemed, medqualifier, qualifierpolar, polarmedium, mediumnereistoxin, nereistoxinamines, aminesdiethanolamine, diethanolaminestreptomycin, streptomycinmepiquat
Dionex IonPac CS21-Fast-4μm
2022|Thermo Fisher Scientific|Manuals
User Manual Dionex IonPac CS21-Fast-4µm 155013 Revision 02 • February 2022 Product Manual for Dionex IonPac CS21-Fast-4µm Analytical Column 303348 IP CS21-Fast-4µm 2×150 mm Dionex IonPac CG21-Fast-4µm Guard Column 303349 IP CG21-Fast-4µm 2×30 mm Thermo Scientific 155013-02 Product Manual for…
Key words
thermo, thermocationic, cationicscientific, scientificcolumn, columnsuppressor, suppressorpolar, polaramine, aminequaternary, quaternaryeluent, eluentpesticides, pesticidesdionex, dionexbed, bedeluents, eluentscontaminated, contaminatedfour
Determination of cationic polar pesticides in cereals using ion chromatography and tandem mass spectroscopy
2022|Thermo Fisher Scientific|Applications
Application note | 000607 Mass spectrometry Determination of cationic polar pesticides in cereals using ion chromatography and tandem mass spectroscopy Authors Goal Terri Christison, John E. Madden, and Demonstrate determinations of quaternary cationic pesticides in oat cereal samples by Jeff…
Key words
mepiquat, mepiquatparaquat, paraquatchlormequat, chlormequatoat, oatdiquat, diquatcereal, cerealtoasted, toasteddionex, dionexsuppressor, suppressorminutes, minutespesticides, pesticidescounts, countsoatmeal, oatmealtsq, tsqmass