Isocyanate content of polyurethane raw materials
Applications | 2020 | MetrohmInstrumentation
The accurate determination of isocyanate content in polyurethane and polyester resins is critical for controlling polymer network formation and end-product performance. Polyurethanes find widespread application in automotive components, building insulation, synthetic fibers and other industrial sectors. Inadequate knowledge of the NCO level can lead to incomplete cure, poor mechanical properties or inconsistent product quality.
This application note demonstrates a reliable, fully automated titration protocol for quantifying isocyanate (NCO) groups in polyurethane (PUR) and unsaturated polyester (UPR) resins in accordance with EN ISO 14896. The aim is to deliver rapid, reproducible results with minimal manual intervention.
Samples of PUR and UPR were analyzed directly without pretreatment. Each sample was weighed into a vessel, mixed with toluene and a dibutylamine/toluene reagent, and allowed to react for exactly 15 minutes. Acetone was then added and the excess dibutylamine was back-titrated with hydrochloric acid until the equivalence point.
Used instrumentation:
Automated titration curves were steep and noise-free, indicating clear equivalence points. Reproducibility was excellent, with relative standard deviations below 2%. In five replicates, PUR samples yielded an NCO content of 2.335% (RSD 0.94%), while UPR samples averaged 0.826% (RSD 1.94%). These figures confirm the method’s precision and robustness.
This automated approach streamlines routine quality control by reducing hands-on time and operator variability. It ensures compliance with industry standards, supports rapid troubleshooting during production and enhances confidence in raw material consistency.
Further developments may include integration with LIMS systems for data traceability, miniaturized titration cells for low-volume samples, and expansion to other reactive polymer chemistries. Combining titration with spectroscopic or chromatographic verification could yield comprehensive raw material profiles.
The EN ISO 14896 titration method for NCO determination can be fully automated to deliver precise, reproducible results with minimal sample preparation. Strict adherence to the 15-minute reaction time is essential for accurate quantification. Automated dosing of reagents is recommended to maintain consistency.
EN ISO 14896: Determination of isocyanate groups in polymeric raw materials by titration
Titration
IndustriesEnergy & Chemicals
ManufacturerMetrohm
Summary
Significance of the Topic
The accurate determination of isocyanate content in polyurethane and polyester resins is critical for controlling polymer network formation and end-product performance. Polyurethanes find widespread application in automotive components, building insulation, synthetic fibers and other industrial sectors. Inadequate knowledge of the NCO level can lead to incomplete cure, poor mechanical properties or inconsistent product quality.
Objectives and Overview
This application note demonstrates a reliable, fully automated titration protocol for quantifying isocyanate (NCO) groups in polyurethane (PUR) and unsaturated polyester (UPR) resins in accordance with EN ISO 14896. The aim is to deliver rapid, reproducible results with minimal manual intervention.
Methodology and Instrumentation
Samples of PUR and UPR were analyzed directly without pretreatment. Each sample was weighed into a vessel, mixed with toluene and a dibutylamine/toluene reagent, and allowed to react for exactly 15 minutes. Acetone was then added and the excess dibutylamine was back-titrated with hydrochloric acid until the equivalence point.
Used instrumentation:
- 907 Titrando high-end titrator with potentiometric endpoint detection
- 814 USB Sample Processor for automated sample handling and dosing
- Solvotrode easyClean nonaqueous pH electrode optimized for low-conductivity media
Main Results and Discussion
Automated titration curves were steep and noise-free, indicating clear equivalence points. Reproducibility was excellent, with relative standard deviations below 2%. In five replicates, PUR samples yielded an NCO content of 2.335% (RSD 0.94%), while UPR samples averaged 0.826% (RSD 1.94%). These figures confirm the method’s precision and robustness.
Benefits and Practical Applications
This automated approach streamlines routine quality control by reducing hands-on time and operator variability. It ensures compliance with industry standards, supports rapid troubleshooting during production and enhances confidence in raw material consistency.
Future Trends and Opportunities
Further developments may include integration with LIMS systems for data traceability, miniaturized titration cells for low-volume samples, and expansion to other reactive polymer chemistries. Combining titration with spectroscopic or chromatographic verification could yield comprehensive raw material profiles.
Conclusion
The EN ISO 14896 titration method for NCO determination can be fully automated to deliver precise, reproducible results with minimal sample preparation. Strict adherence to the 15-minute reaction time is essential for accurate quantification. Automated dosing of reagents is recommended to maintain consistency.
Reference
EN ISO 14896: Determination of isocyanate groups in polymeric raw materials by titration
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Acid value, hydroxyl value, and isocyanates in raw materials for the fabrication of plastics
|Metrohm|Applications
Application Bulletin 200/3 e Acid value, hydroxyl value, and isocyanates in raw materials for the fabrication of plastics Determination by automatic potentiometric titration according to various standards Branch General analytical chemistry; organic chemistry, chemistry; plastics, photographic industry Keywords Titration; potentiometric…
Key words
titrant, titranttiter, titertitration, titrationpotentiometric, potentiometricdet, dethydroxyl, hydroxylfabrication, fabricationequivalence, equivalenceplastics, plasticsvalue, valuesample, samplecriterion, criterionuntil, untilrecognition, recognitionacid
Nicotine in E-liquids
2020|Metrohm|Applications
AN-T-208 Nicotine in E-liquids Reliable and affordable determination by potentiometric titration Summary The vaping and electronic cigarette industries have grown impressively in the past decade. Usage among youths has increased from around 1% in 2011 to 10.5–27.5% in 2019 (preteens…
Key words
metrohm, metrohmnicotine, nicotinetitration, titrationtitrated, titratedpotentiometric, potentiometricequivalence, equivalencehydrochloric, hydrochloricstandardized, standardizedeasyclean, easycleanitrode, itrodeuntil, untilstirrers, stirrersmsb, msbdiaphragm, diaphragmrel
Metrohm 907 Titrando
2022|Metrohm|Manuals
907 Titrando Manual 8.907.8003EN / 2022-01-12 Metrohm AG CH-9100 Herisau Switzerland +41 71 353 85 85 [email protected] www.metrohm.com 907 Titrando Manual 8.907.8003EN / 2022-01-12 / Technical Communication Metrohm AG CH-9100 Herisau This documentation is protected by copyright. All rights reserved.…
Key words
titration, titrationconnecting, connectingelectrode, electrodedosing, dosingpolarization, polarizationtouch, touchremote, remotemsb, msbusb, usbmeasuring, measuringcable, cablemeasurement, measurementwarning, warningselectable, selectablecontrol
Nicotine content in tobacco
2020|Metrohm|Applications
AN-T-175 Nicotine content in tobacco Cost-efficient method using non-aqueous titration Summary Nicotine is an N-containing alkaloid that stimulates the parasympathetic nervous system, and is both highly addictive and dangerous to human health. Its toxic threshold value lies between 30–60 mg…
Key words
nicotine, nicotinemetrohm, metrohmtobacco, tobaccotitration, titrationchloride, chlorideselective, selectiveperchloric, perchloricomnis, omnisglacial, glacialbarium, bariumrel, reltitrator, titratorequivalence, equivalencesituations, situationsleaves