Clarity Control Module SHIMADZU LC-10/20 SYSTEM

Manuals | 2024 | DataApexInstrumentation
HPLC, Software
Industries
Other
Manufacturer
Shimadzu, DataApex

Summary

Importance of Topic


Liquid chromatography is a cornerstone technique for separating and quantifying complex mixtures in pharmaceuticals, environmental testing, food safety and research laboratories.
Centralized software control of LC systems improves efficiency, reproducibility and data integrity by automating gradient profiles, sample handling, detection parameters and temperature programs.

Objective and Overview


This summary presents the integration of the Shimadzu LC-10/20 System with Clarity software, covering installation prerequisites, communication methods, device configuration, method programming, real-time monitoring and report generation.
It highlights how multiple hardware modules—pumps, detectors, autosamplers, PDA detectors and thermostats—are managed through a unified control interface.

Methodology and Instrumentation


Used Instrumentation


  • Controllers: SCL-10Avp, CBM-20A, CBM-20ALite (serial or LAN interface)
  • Pumps: LC-6AD, LC-8A, LC-10AD/AT/AS/Ai, LC-20 series
  • Detectors: SPD-10/20 UV, RF-10/20 fluorescence, RID-10/20 refractive index
  • Autosamplers: SIL-10ADvp/AF/Axl, SIL-HTA/HTC, SIL-20 series
  • PDA detectors: SPD-M10Avp (SCSI), SPD-M20A (LAN)
  • Thermostats: CTO-10A/AC/AS/vp, CTO-20 series

Communication is via RS-232 (DB9F-DB9F) or Ethernet (LC-20 controllers).
Clarity configuration requires proper .NET installation, specific device firmware versions and correct cable types. Each device is added and parametrized within Clarity’s System Configuration dialogs.

Key Results and Discussion


  • Gradient Control: Multi-solvent mixing tables with time-based composition, flow adjustments, standby and idle modes.
  • Pump Monitoring: Live flow/pressure readouts, manual override, hold/resume and predefined safety limits.
  • Detector Integration: Automated UV/vis, fluorescence and refractive index settings with time-programmed changes in wavelength, lamp and sensitivity.
  • Autosampler Automation: Configurable racks, vials, rinse cycles, dilution and reagent pretreatment routines, plus cooled tray handling.
  • PDA Operation: Full spectral acquisition, analog single-wavelength outputs with customizable bandwidth, slit width and sampling rates.
  • Thermostat Programming: Temperature setpoints, linear ramps, valve switching and device status monitoring.
  • Reporting: Comprehensive method export, including parameter tables, time programs and event logs.

Benefits and Practical Applications


  • Unified control streamlines workflow setup and reduces manual errors in QC, R&D and production laboratories.
  • Time-based events ensure reproducible gradient elutions, temperature profiles and detector responses for complex assays.
  • Real-time monitoring with alarm outputs enhances safety by preventing overpressure and hardware damage.
  • Automated sample handling increases throughput and supports advanced pretreatment steps for concentration, dilution and derivatization.
  • Detailed audit trails and customizable reports support regulatory compliance in GMP and ISO environments.

Future Trends and Possibilities


Emerging developments include cloud-based instrument monitoring, remote method development, predictive maintenance via machine learning and enhanced cybersecurity.
AI-driven sequence optimization and automated fault detection will further reduce manual intervention.
Integration with LIMS/ELN platforms will enable seamless data management and regulatory reporting.

Conclusion


The Shimadzu LC-10/20 System control module in Clarity software offers a versatile, centralized interface for modern HPLC operations.
By supporting diverse modules and communication options, it enables fully automated, reproducible analyses with advanced monitoring and reporting features.
This approach enhances laboratory efficiency, data integrity and method transferability across analytical settings.

Reference


DataApex Ltd. and Shimadzu Corporation system and software manuals (2024).

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Clarity Control Module INTERLAB MAESTRO
INTERLAB MAESTRO Clarity Control Module ENG Code/Rev.: M184/90C Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
interlab, interlabmaestro, maestrotab, tabthemethod, themethodmonitor, monitordevice, devicelamp, lampsetup, setupdialog, dialogoff, offdetector, detectorwavelength, wavelengthstandby, standbymaintenance, maintenanceprogram
Clarity Control Module HITACHI PRIMAIDE
HITACHI PRIMAIDE Clarity Control Module ENG Code/Rev.: M183/90D Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
primaide, primaidehitachi, hitachitab, tabclarityva, clarityvadialog, dialogthemethod, themethodmonitor, monitorsetup, setupdevice, devicelamp, lampstandby, standbyidle, idleoff, offmaintenance, maintenancetime
Clarity Control Module HITACHI CHROMASTER
HITACHI CHROMASTER Clarity Control Module ENG Code/Rev.: M173/90E Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
chromaster, chromasterhitachi, hitachithemethod, themethodtab, tablamp, lampmonitor, monitordevice, deviceclarityva, clarityvasetup, setupwavelength, wavelengthdialog, dialogoff, offdetector, detectorprogram, programtime
Clarity Control Module AGILENT 1100/1200
Clarity Control Module AGILENT 1100/1200
2024|Agilent Technologies|Manuals
AGILENT 1100/1200 Clarity Control Module ENG Code/Rev.: M060/80D Date: 11/1/2022 DataApex Ltd. Phone: +420 251 013 400 [email protected] www.dataapex.com Petrzilkova 2583/13 158 00 Prague 5 The Czech Republic ® are trademarks of DataApex Ltd. Microsoft ® and Windows TM are…
Key words
device, deviceclarity, claritylamp, lampdialog, dialogserial, serialmonitor, monitorset, setgpib, gpibbutton, buttonwavelength, wavelengthwindow, windowlan, lanzero, zerostate, stateautozero
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike