Clarity Control Module HITACHI PRIMAIDE
Manuals | 2024 | DataApexInstrumentation
The integration of chromatographic instrumentation with centralized software control has become essential for modern analytical laboratories. Direct communication between HPLC modules and data acquisition platforms enhances reproducibility, streamlines workflows and minimizes manual intervention. The ability to configure, monitor and adjust modules in real time supports high-throughput analysis, robust quality control and efficient method development in pharmaceutical, environmental and industrial laboratories.
This document presents the implementation and configuration of the Hitachi Primaide control module within the ClarityVA chromatography station. The objectives include establishing reliable USB communication with multiple HPLC components, enabling method transfer, automating gradient and temperature programs, and providing comprehensive online monitoring and manual override capabilities. The study covers installation requirements, system configuration steps and operational procedures for pumps, autosampler, column oven, PDA and UV detectors.
System integration begins by selecting the appropriate USB interface board and installing control modules for each HPLC component. Autodetection or manual entry of serial and program numbers links hardware modules to the ClarityVA station. Method setup dialogs enable definition of gradient tables, solvent names and pressure limits for the pump, injection timing and wash protocols for the autosampler, temperature programs and valve positions for the oven, and detector settings including wavelengths, response time and sampling intervals. Device Monitor panels provide live feedback on flow, pressure, temperature and detector baselines. Manual overrides such as on-the-fly gradient modification, manual flow adjustment and pump hold/resume allow dynamic troubleshooting without disrupting the overall sequence.
Implementation of the Hitachi Primaide control module in ClarityVA achieved full command over all system components from a single software platform. Gradient execution synchronized solvent mixing and pressure checks, ensuring safe operation within defined limits. Autosampler integration supported vial detection, thermal control and programmable wash routines. Column oven temperature profiles were precisely managed with automated switching of pneumatic valves. PDA and UV detectors delivered multiwavelength acquisition, time-programmed wavelength changes and baseline stabilization through autozero functions. The audit trail captured all method transmissions and manual adjustments, facilitating traceability and compliance with regulatory standards.
Future developments may include expansion of supported modules for capillary and preparative LC, deeper integration with laboratory information management systems, cloud-based method libraries and remote monitoring dashboards. Incorporation of machine learning algorithms for predictive maintenance, gradient optimization and anomaly detection promises to further enhance instrument uptime and method robustness. Standardization of communication protocols between vendors may drive universal control platforms and plug-and-play interoperability.
The Hitachi Primaide control module for ClarityVA delivers an integrated solution for HPLC system management, streamlining the configuration, execution and monitoring of pumps, autosampler, column oven and detectors. Its comprehensive feature set, real-time overrides and audit capabilities support high-performance laboratories in achieving reliable, reproducible and compliant analyses.
– no external references provided
HPLC, Software
IndustriesOther
ManufacturerDataApex
Summary
Significance of the Topic
The integration of chromatographic instrumentation with centralized software control has become essential for modern analytical laboratories. Direct communication between HPLC modules and data acquisition platforms enhances reproducibility, streamlines workflows and minimizes manual intervention. The ability to configure, monitor and adjust modules in real time supports high-throughput analysis, robust quality control and efficient method development in pharmaceutical, environmental and industrial laboratories.
Objectives and Study Overview
This document presents the implementation and configuration of the Hitachi Primaide control module within the ClarityVA chromatography station. The objectives include establishing reliable USB communication with multiple HPLC components, enabling method transfer, automating gradient and temperature programs, and providing comprehensive online monitoring and manual override capabilities. The study covers installation requirements, system configuration steps and operational procedures for pumps, autosampler, column oven, PDA and UV detectors.
Used Instrumentation
- Hitachi Primaide HPLC control module with USB-IF interface board
- Pump 1110
- UV detector 1410 and PDA detector 1430
- Autosampler 1210
- Column oven thermostat 1310
- ClarityVA software with LC control and optional AS and PDA extensions
Methodology and Instrumentation
System integration begins by selecting the appropriate USB interface board and installing control modules for each HPLC component. Autodetection or manual entry of serial and program numbers links hardware modules to the ClarityVA station. Method setup dialogs enable definition of gradient tables, solvent names and pressure limits for the pump, injection timing and wash protocols for the autosampler, temperature programs and valve positions for the oven, and detector settings including wavelengths, response time and sampling intervals. Device Monitor panels provide live feedback on flow, pressure, temperature and detector baselines. Manual overrides such as on-the-fly gradient modification, manual flow adjustment and pump hold/resume allow dynamic troubleshooting without disrupting the overall sequence.
Main Results and Discussion
Implementation of the Hitachi Primaide control module in ClarityVA achieved full command over all system components from a single software platform. Gradient execution synchronized solvent mixing and pressure checks, ensuring safe operation within defined limits. Autosampler integration supported vial detection, thermal control and programmable wash routines. Column oven temperature profiles were precisely managed with automated switching of pneumatic valves. PDA and UV detectors delivered multiwavelength acquisition, time-programmed wavelength changes and baseline stabilization through autozero functions. The audit trail captured all method transmissions and manual adjustments, facilitating traceability and compliance with regulatory standards.
Benefits and Practical Applications
- Centralized control simplifies method management and reduces training requirements
- Live device monitoring and manual overrides improve troubleshooting and uptime
- Automated gradient, temperature and injection programs increase throughput
- Audit trail and pressure safeguards protect hardware and ensure data integrity
- Modular design allows incremental system upgrades and tailored configurations
Future Trends and Opportunities
Future developments may include expansion of supported modules for capillary and preparative LC, deeper integration with laboratory information management systems, cloud-based method libraries and remote monitoring dashboards. Incorporation of machine learning algorithms for predictive maintenance, gradient optimization and anomaly detection promises to further enhance instrument uptime and method robustness. Standardization of communication protocols between vendors may drive universal control platforms and plug-and-play interoperability.
Conclusion
The Hitachi Primaide control module for ClarityVA delivers an integrated solution for HPLC system management, streamlining the configuration, execution and monitoring of pumps, autosampler, column oven and detectors. Its comprehensive feature set, real-time overrides and audit capabilities support high-performance laboratories in achieving reliable, reproducible and compliant analyses.
Reference
– no external references provided
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Clarity Control Module HITACHI CHROMASTER
2024|DataApex|Manuals
HITACHI CHROMASTER Clarity Control Module ENG Code/Rev.: M173/90E Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
chromaster, chromasterhitachi, hitachithemethod, themethodtab, tablamp, lampmonitor, monitordevice, deviceclarityva, clarityvasetup, setupwavelength, wavelengthoff, offdialog, dialogdetector, detectorprogram, programtime
Clarity Control Module INTERLAB MAESTRO
2024|DataApex|Manuals
INTERLAB MAESTRO Clarity Control Module ENG Code/Rev.: M184/90C Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
interlab, interlabmaestro, maestrotab, tabthemethod, themethodmonitor, monitordevice, devicelamp, lampsetup, setupdialog, dialogoff, offdetector, detectorwavelength, wavelengthstandby, standbymaintenance, maintenanceprogram
Clarity Control Module YOUNGIN CHROMASS YL9140 FLD
2024|DataApex|Manuals
YOUNGIN CHROMASS YL9140 FLD Clarity Control Module ENG Code/Rev.: M244/90D Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®,…
Key words
youngin, younginlamp, lamptab, tabwavelength, wavelengthdevice, deviceclarity, claritymonitor, monitormodule, modulemodules, modulesoff, offcontrol, controlthemethod, themethodboard, boardadd, addusb
Clarity Control Module SHIMADZU LC-10/20 SYSTEM
2024|Shimadzu|Manuals
SHIMADZU LC-10/20 SYSTEM Clarity Control Module ENG Code/Rev.: M108/80D Date: 10/27/2022 DataApex Ltd. Phone: +420 251 013 400 [email protected] www.dataapex.com Petrzilkova 2583/13 158 00 Prague 5 The Czech Republic ® are trademarks of DataApex Ltd. Microsoft ® and Windows TM…
Key words
monitor, monitordevice, devicetab, tabdialog, dialogsetup, setupsets, setswindow, windowwavelength, wavelengthtable, tablethermostat, thermostatflow, flowtemperature, temperaturepump, pumpstandby, standbybutton