Clarity Control Module YOUNGIN CHROMASS YL9140 FLD
Manuals | 2024 | DataApexInstrumentation
The YoungIn Chromass YL9140 FLD fluorescence detector is a key tool in high-performance liquid chromatography (HPLC) for sensitive and selective analysis of compounds exhibiting native or derivatized fluorescence. Seamless integration of this detector into the Clarity chromatography software ensures centralized control, reliable data acquisition, and streamlined maintenance—critical factors for method development, quality control, and high-throughput laboratories.
This document guides users through the setup, configuration, operation, and troubleshooting of the YL9140 FLD Control Module within the Clarity environment. It covers system prerequisites, hardware and software installation steps, method parameterization, real-time monitoring capabilities, part maintenance procedures, and communication diagnostics.
The control module communicates with up to four YL9140 FLD detectors via USB-IF Boards (Sys1–Sys4). Module autodetection or manual addition in Clarity’s System Configuration links each detector to a virtual instrument. Method Setup allows definition of excitation/emission wavelengths, PMT voltage, signal filtering (sample period and response time), emission bandwidth, and leak sensor status. A time program feature enables dynamic wavelength and voltage changes during runs. Digital I/O triggers and auto-zero functions ensure synchronization with chromatography events.
Configuration tests confirm reliable bi-directional communication: Clarity sends method parameters to the detector and retrieves status, signal, and maintenance counters. The Device Monitor provides live feedback, lamp control, and manual zeroing. Time-programmed wavelength switching accommodates multi-analyte assays within one injection. Part maintenance logs track lamp usage and alert users when soft limits are reached, improving preventive maintenance.
Emerging detector technologies—such as LED-based excitation, multi-channel detectors, and faster electronics—will further enhance sensitivity, dynamic range, and throughput. Integration of AI-driven method optimization and predictive maintenance algorithms will reduce manual intervention. Cloud-based data management and remote monitoring will support distributed laboratories and regulatory compliance workflows.
The YoungIn Chromass YL9140 FLD Control Module in Clarity offers comprehensive instrument integration, enabling precise configuration, real-time monitoring, and preventive maintenance. Its robust feature set ensures reproducible, high-sensitivity fluorescence detection tailored to modern analytical chemistry demands.
Software, HPLC
IndustriesOther
ManufacturerDataApex
Summary
Significance of the Topic
The YoungIn Chromass YL9140 FLD fluorescence detector is a key tool in high-performance liquid chromatography (HPLC) for sensitive and selective analysis of compounds exhibiting native or derivatized fluorescence. Seamless integration of this detector into the Clarity chromatography software ensures centralized control, reliable data acquisition, and streamlined maintenance—critical factors for method development, quality control, and high-throughput laboratories.
Objectives and Overview
This document guides users through the setup, configuration, operation, and troubleshooting of the YL9140 FLD Control Module within the Clarity environment. It covers system prerequisites, hardware and software installation steps, method parameterization, real-time monitoring capabilities, part maintenance procedures, and communication diagnostics.
Methodology and Instrumentation
The control module communicates with up to four YL9140 FLD detectors via USB-IF Boards (Sys1–Sys4). Module autodetection or manual addition in Clarity’s System Configuration links each detector to a virtual instrument. Method Setup allows definition of excitation/emission wavelengths, PMT voltage, signal filtering (sample period and response time), emission bandwidth, and leak sensor status. A time program feature enables dynamic wavelength and voltage changes during runs. Digital I/O triggers and auto-zero functions ensure synchronization with chromatography events.
Instrumentation Used
- YoungIn Chromass YL9140 FLD fluorescence detector
- USB-IF Board for USB communication (Sys1–Sys4)
- PC running Clarity Control Module (A24) on Windows 7 (32/64 bit)
Main Results and Discussion
Configuration tests confirm reliable bi-directional communication: Clarity sends method parameters to the detector and retrieves status, signal, and maintenance counters. The Device Monitor provides live feedback, lamp control, and manual zeroing. Time-programmed wavelength switching accommodates multi-analyte assays within one injection. Part maintenance logs track lamp usage and alert users when soft limits are reached, improving preventive maintenance.
Benefits and Practical Applications
- Unified control and data handling within Clarity software
- High sensitivity and selectivity through programmable fluorescence settings
- Automated lamp life tracking and maintenance alerts for consistent performance
- Flexible time-program capabilities for complex analytical methods
Future Trends and Applications
Emerging detector technologies—such as LED-based excitation, multi-channel detectors, and faster electronics—will further enhance sensitivity, dynamic range, and throughput. Integration of AI-driven method optimization and predictive maintenance algorithms will reduce manual intervention. Cloud-based data management and remote monitoring will support distributed laboratories and regulatory compliance workflows.
Conclusion
The YoungIn Chromass YL9140 FLD Control Module in Clarity offers comprehensive instrument integration, enabling precise configuration, real-time monitoring, and preventive maintenance. Its robust feature set ensures reproducible, high-sensitivity fluorescence detection tailored to modern analytical chemistry demands.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Clarity Control Module INTERLAB MAESTRO
2024|DataApex|Manuals
INTERLAB MAESTRO Clarity Control Module ENG Code/Rev.: M184/90C Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
interlab, interlabmaestro, maestrotab, tabthemethod, themethodmonitor, monitordevice, devicelamp, lampsetup, setupdialog, dialogoff, offdetector, detectorwavelength, wavelengthstandby, standbytime, timemaintenance
Clarity Control Module HITACHI CHROMASTER
2024|DataApex|Manuals
HITACHI CHROMASTER Clarity Control Module ENG Code/Rev.: M173/90E Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
chromaster, chromasterhitachi, hitachitab, tabthemethod, themethodlamp, lampmonitor, monitordevice, deviceclarityva, clarityvasetup, setupwavelength, wavelengthoff, offdialog, dialogdetector, detectorprogram, programtime
Clarity Control Module HITACHI PRIMAIDE
2024|DataApex|Manuals
HITACHI PRIMAIDE Clarity Control Module ENG Code/Rev.: M183/90D Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
primaide, primaidehitachi, hitachitab, tabclarityva, clarityvadialog, dialogthemethod, themethodmonitor, monitorsetup, setupdevice, devicelamp, lampstandby, standbyidle, idleoff, offmaintenance, maintenancetime
Clarity Control Module AGILENT 1100/1200
2024|Agilent Technologies|Manuals
AGILENT 1100/1200 Clarity Control Module ENG Code/Rev.: M060/80D Date: 11/1/2022 DataApex Ltd. Phone: +420 251 013 400 [email protected] www.dataapex.com Petrzilkova 2583/13 158 00 Prague 5 The Czech Republic ® are trademarks of DataApex Ltd. Microsoft ® and Windows TM are…
Key words
device, deviceclarity, claritylamp, lampdialog, dialogserial, serialmonitor, monitorset, setgpib, gpibbutton, buttonwindow, windowwavelength, wavelengthlan, lanstate, statezero, zeroautozero