High-performance liquid chromatography (HPLC) remains a cornerstone technique in analytical chemistry for separating, identifying and quantifying complex mixtures. Seamless control of advanced HPLC systems such as the Shimadzu Nexera by user-friendly software enhances method reproducibility, data integrity and workflow efficiency across research, quality control and industrial laboratories.
This document outlines the complete process for integrating Shimadzu Nexera with the Clarity – Shimadzu Edition chromatography station. Key aims include guiding the user through software and hardware requirements, installation, system configuration, method setup and troubleshooting to ensure reliable instrument operation.
The integration relies on the Shimadzu RC.NET driver operating under Agilent’s Instrument Control Framework (ICF) within Clarity – Shimadzu Edition. The installation workflow covers:
The manual demonstrates successful integration through step-by-step procedures: installation of the correct ICF version; network setup and firewall considerations; Connect Key entry; instrument configuration in Clarity System Configuration; detailed method setup across Acquisition, AS, Aux, LC, PDA and Thermostat tabs; monitoring via Device Monitor; and customizing startup, shutdown and sequence modes in the Nexera Series Setup. Troubleshooting covers common errors such as ICF version mismatches, connection failures (ping diagnostics) and license or module-support issues.
Centralized HPLC control within Clarity enhances compliance with regulatory standards and audit trails. Users gain flexible method programming for gradient delivery, autosampler sequencing, real-time signal output for fraction collection, and automated shutdown behaviors. The integrated environment simplifies maintenance, reduces operator training and supports high-throughput analyses.
Advances are expected in cloud-based instrument monitoring, remote method development, AI-driven troubleshooting and predictive maintenance. Integration with laboratory information management systems (LIMS) and Internet-of-Things (IoT) connectivity will further optimize data access, facilitate collaborative research and improve instrument uptime.
The document provides a comprehensive blueprint for deploying Shimadzu Nexera control within Clarity – Shimadzu Edition. By following the outlined installation, configuration and troubleshooting steps, laboratories can achieve robust, reproducible and user-friendly HPLC workflows.
HPLC, Software
IndustriesOther
ManufacturerShimadzu, DataApex
Summary
Importance of the Topic
High-performance liquid chromatography (HPLC) remains a cornerstone technique in analytical chemistry for separating, identifying and quantifying complex mixtures. Seamless control of advanced HPLC systems such as the Shimadzu Nexera by user-friendly software enhances method reproducibility, data integrity and workflow efficiency across research, quality control and industrial laboratories.
Objectives and Study Overview
This document outlines the complete process for integrating Shimadzu Nexera with the Clarity – Shimadzu Edition chromatography station. Key aims include guiding the user through software and hardware requirements, installation, system configuration, method setup and troubleshooting to ensure reliable instrument operation.
Methodology and Instrumentation
The integration relies on the Shimadzu RC.NET driver operating under Agilent’s Instrument Control Framework (ICF) within Clarity – Shimadzu Edition. The installation workflow covers:
- Verifying software prerequisites: Windows 10/11 (64 bit), Microsoft .NET 3.5 for installation and .NET 4.8+ for operation.
- Acquiring required licenses: Clarity – Shimadzu Edition OEM, LC Control and Shimadzu-specific LC driver licenses; optional autosampler and PDA extensions.
- Ensuring hardware readiness: LAN interface, compatible module firmware and IP address assignment on the same subnet.
- Entering the controller-specific Connect Key via Edge in Internet Explorer mode to authorize communication.
- Configuring the system in Clarity with the Nexera Series Setup dialog, mapping individual modules to software instrument tabs.
Used Instrumentation
- Shimadzu Nexera Series HPLC with CBM-40, CBM-40 Lite or SCL-40 controller
- Pumps: LC-40B/40D series; autosampler: SIL-40 series; column oven: CTO-40C; detectors: SPD-40 (PDA), RID-20A, RF-20A, CDD-10Avp
- Software: Clarity – Shimadzu Edition (OEM), Agilent Instrument Control Framework, Microsoft .NET Framework
- Network: direct LAN or cross-over cable, TCP/IP
Main Results and Discussion
The manual demonstrates successful integration through step-by-step procedures: installation of the correct ICF version; network setup and firewall considerations; Connect Key entry; instrument configuration in Clarity System Configuration; detailed method setup across Acquisition, AS, Aux, LC, PDA and Thermostat tabs; monitoring via Device Monitor; and customizing startup, shutdown and sequence modes in the Nexera Series Setup. Troubleshooting covers common errors such as ICF version mismatches, connection failures (ping diagnostics) and license or module-support issues.
Benefits and Practical Applications
Centralized HPLC control within Clarity enhances compliance with regulatory standards and audit trails. Users gain flexible method programming for gradient delivery, autosampler sequencing, real-time signal output for fraction collection, and automated shutdown behaviors. The integrated environment simplifies maintenance, reduces operator training and supports high-throughput analyses.
Future Trends and Applications
Advances are expected in cloud-based instrument monitoring, remote method development, AI-driven troubleshooting and predictive maintenance. Integration with laboratory information management systems (LIMS) and Internet-of-Things (IoT) connectivity will further optimize data access, facilitate collaborative research and improve instrument uptime.
Conclusion
The document provides a comprehensive blueprint for deploying Shimadzu Nexera control within Clarity – Shimadzu Edition. By following the outlined installation, configuration and troubleshooting steps, laboratories can achieve robust, reproducible and user-friendly HPLC workflows.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Clarity Control Module AGILENT ICF FOR LC
2024|Agilent Technologies|Manuals
AGILENT ICF FOR LC Clarity Control Module ENG Code/Rev.: M155/80M Date: 11/1/2022 DataApex Ltd. Phone: +420 251 013 400 [email protected] www.dataapex.com Petrzilkova 2583/13 158 00 Prague 5 The Czech Republic ® are trademarks of DataApex Ltd. Microsoft ® and Windows…
Key words
icf, icfagilent, agilentclarity, claritydialog, dialogsetup, setupconfiguration, configurationaddress, addressconfigured, configuredhostname, hostnamedevice, devicetab, tablan, lanyou, youconfigure, configuredisplayed
Clarity Control Module CTC PAL3 SYSTEM
2024|DataApex|Manuals
CTC PAL3 SYSTEM Clarity Control Module ENG Code/Rev.: M224/100A Date: 2024-10-17 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex®…
Key words
clarity, clarityicf, icflan, lanconfiguration, configurationcommand, commandmonitor, monitoragilent, agilentctc, ctcdialog, dialogping, pingsubnet, subnettab, tabdevice, devicecommunication, communicationversion
Clarity Control Module AXCEND FOCUS LC
2025|DataApex|Manuals
AXCEND FOCUS LC Clarity Control Module ENG Code/Rev.: M246/100B Date: 2025-05-16 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex®…
Key words
axcend, axcendfocus, focusclarity, clarityicf, icfcommand, commanddevice, devicesetup, setupdialog, dialogping, pinginstrument, instrumentfirewall, firewallmonitor, monitorcommunication, communicationcontrol, controlversion
Clarity Control Module AGILENT 1100/1200
2024|Agilent Technologies|Manuals
AGILENT 1100/1200 Clarity Control Module ENG Code/Rev.: M060/80D Date: 11/1/2022 DataApex Ltd. Phone: +420 251 013 400 [email protected] www.dataapex.com Petrzilkova 2583/13 158 00 Prague 5 The Czech Republic ® are trademarks of DataApex Ltd. Microsoft ® and Windows TM are…
Key words
device, deviceclarity, claritylamp, lampdialog, dialogserial, serialmonitor, monitorset, setgpib, gpibbutton, buttonwavelength, wavelengthwindow, windowlan, lanstate, statezero, zeroautozero