WCPS: Metal Release Analysis of the new 1260 Infinity Bio-inert HPLC System by 7700 ICP-MS
Posters | 2011 | Agilent TechnologiesInstrumentation
HPLC, ICP/MS, Speciation analysis
IndustriesManufacturerAgilent Technologies
Key wordscorrosion, bio, metal, naoh, hplc, fellner, realease, mobile, fact, zink, nicole, pump, metals, jochen, strassner, stainless, formic, steel, phosphate, icp, inert, path, sodium, from, appropriate, high, low, prerequisite, extremes, detected, values, reflects, wetted, technical, where, applications, speciation, exchanger, were, earlier, notice, illustrate, acid, due, inertness, dad, agilent, replaced, normally, resistance
Similar PDF
Robustness and Metal Release Testing of the New Agilent 1260 Infinity Bio-inert LC with Agilent 7700 ICP-MS
|Agilent Technologies|Posters
Robustness and Metal Release Testing of the New Agilent 1260 Infinity Bio-inert LC with Agilent 7700 ICP-MS Hyphenated separations: LC-MS, CE-MS, and LC-NMR Nicole Fellner, Jochen Strassner, Katja Kornetzky Agilent Technologies, R&D and Marketing GmbH, Hewlett Packard-Str. 8 , 76337…
Key words
pump, pumpbio, bioinert, inertmetal, metalstrenuous, strenuousbioinertness, bioinertnessformic, formicstressing, stressingsystem, systemlowest, lowesttreatment, treatmentcontaminants, contaminantsleaching, leachingblocked, blockedeven
Determination of Low-Metal Release Using the Agilent 1260 Infinity II Bio‑inert LC with ICP-MS
2017|Agilent Technologies|Technical notes
Determination of Low-Metal Release Using the Agilent 1260 Infinity II Bio‑inert LC with ICP-MS Technical Overview Authors Abstract Majlinda Xhaferaj, Jörg Hippler, and Proteins are chelating agents, and metals such as iron are often found in Sonja Schneider protein-metal complexes.…
Key words
bio, biometal, metalmetals, metalsinert, inertmanganese, manganesesystem, systemnickel, nickeliron, ironeluents, eluentsrelease, releaseleaching, leachingflushed, flushedchromium, chromiumflushing, flushingwere
HANDBOOK OF HYPHENATED ICP-MS APPLICATIONS - 2nd Edition
2015|Agilent Technologies|Guides
HANDBOOK OF HYPHENATED ICP-MS APPLICATIONS 2nd Edition Foreword Without doubt, speciation analysis has found its rightful place as a valuable methodology within the toolbox of analytical science. The enhanced information value provided by speciation analysis compared to classical elemental analysis…
Key words
icp, icpspeciation, speciationspecies, specieshplc, hplcarsenic, arsenicflow, flowmercury, mercuryrate, ratefff, fffgas, gasselenium, seleniumdetermination, determinationkeywords, keywordsplasma, plasmausing
Low-level speciated analysis of Cr(III) and Cr(VI) using LC(IC)-ICP-MS
2012|Agilent Technologies|Applications
Low-level speciated analysis of Cr(III) and Cr(VI) using LC(IC)-ICP-MS Application note Environmental Authors Mina Tanoshima1, Tetsushi Sakai1, Craig Jones2 1. Agilent Technologies Tokyo, Japan 2. Agilent Technologies Santa Clara, CA, USA Introduction Chromium (Cr) is used in stainless steel and…
Key words
iii, iiiwater, waterspiked, spikedtap, tapmodified, modifiededta, edtaunspiked, unspikedicp, icpaverage, averagedrinking, drinkingwaters, watersboth, bothhealth, healthinterferences, interferencescalifornia