Robustness and Metal Release Testing of the New Agilent 1260 Infinity Bio-inert LC with Agilent 7700 ICP-MS
Posters | | Agilent TechnologiesInstrumentation
HPLC, ICP/MS, Speciation analysis
IndustriesManufacturerAgilent Technologies
Key wordspump, bio, inert, metal, strenuous, bioinertness, formic, stressing, system, lowest, treatment, contaminants, even, blocked, leaching, harsh, titanium, under, hence, evident, flushing, extreme, corrosion, mostly, after, demanding, acid, inertness, crucial, demonstrating, subsequently, displays, resistance, consists, outlet, activity, chromatography, interaction, introduced, flow, path, conditions, robustness, data, demonstrates, surface, protein, make, results, shows
Similar PDF
Determination of Low-Metal Release Using the Agilent 1260 Infinity II Bio‑inert LC with ICP-MS
2017|Agilent Technologies|Technical notes
Determination of Low-Metal Release Using the Agilent 1260 Infinity II Bio‑inert LC with ICP-MS Technical Overview Authors Abstract Majlinda Xhaferaj, Jörg Hippler, and Proteins are chelating agents, and metals such as iron are often found in Sonja Schneider protein-metal complexes.…
Key words
bio, biometal, metalmetals, metalsinert, inertmanganese, manganesesystem, systemiron, ironnickel, nickeleluents, eluentsrelease, releaseleaching, leachingflushed, flushedchromium, chromiumflushing, flushingwere
WCPS: Metal Release Analysis of the new 1260 Infinity Bio-inert HPLC System by 7700 ICP-MS
2011|Agilent Technologies|Posters
Metal Release Analysis of the new 1260 Infinity Bio-inert HPLC System by 7700 ICP-MS Nicole Fellner and Jochen Strassner Abstract Results and Discussion Many analytical applications like the analysis of large bio-molecules or speciation in ultra low-levels of metals with…
Key words
corrosion, corrosionbio, biometal, metalnaoh, naohhplc, hplcfellner, fellnerrealease, realeasemobile, mobilefact, factzink, zinkmetals, metalspump, pumpnicole, nicolestainless, stainlessjochen
Agilent ICP-MS Journal (October 2013 – Issue 55)
2013|Agilent Technologies|Others
Agilent ICP-MS Journal October 2013 – Issue 55 Inside this Issue 2-3 Analysis of Metals in Rock and Mineral Samples Reference Materials by ICP-MS 4 User article: Agilent Partners with RSSL to Create a New Atomic Spectroscopy Center of Excellence…
Key words
gas, gasicp, icprssl, rsslmetals, metalstoy, toyelements, elementsagilent, agilentplatinum, platinumblood, bloodcredit, creditistds, istdscones, conesnew, newmineral, mineralcalibration
Handbook of ICP-QQQ Applications using the Agilent 8800 and 8900
2022|Agilent Technologies|Guides
5th Edition Handbook of ICP-QQQ Applications using the Agilent 8800 and 8900 Primer > Return to table of contents > Search entire document Foreword Agilent Technologies launched its 8800 Triple Quadrupole ICP-MS (ICP-QQQ) at the 2012 Winter Conference on Plasma…
Key words
return, returncontents, contentstable, tableicp, icpqqq, qqqcps, cpsgas, gasmass, masscell, cellppt, pptdocument, documentconc, concentire, entiresearch, searchelements