Suppressor «Top Lucina α-M» in acid copper baths (Okuno Chemical Industries)

Applications |  | MetrohmInstrumentation
Voltammetry/Coulometry
Industries
Energy & Chemicals
Manufacturer
Metrohm

Summary

Importance of the Topic


Acid copper electroplating is a cornerstone of electronics manufacturing and decorative metal finishing. Suppressor additives such as Top Lucina α-M play a critical role in regulating deposit thickness, surface smoothness, and throwing power. Reliable quantification of these polymeric suppressors is essential to ensure consistent bath performance and product quality.

Objectives and Study Overview


This study presents a rapid and accurate approach for determining the concentration of Top Lucina α-M in acid copper plating baths. By combining cyclic voltammetric stripping (CVS) with a dilution titration (DT) calibration, the method aims to offer straightforward implementation for routine quality control.

Methodology and Instrumentation Used


No sample pretreatment is required; the bath solution is analyzed directly in a virgin make-up solution (VMS) containing CuSO4, H2SO4, and NaCl at supplier-specified levels. Key instrumentation and parameters include:
  • Electrochemical cell volume: 50 mL VMS
  • Working electrode: Platinum rotating disk electrode (drive shaft 6.1246.000 with Pt tip 6.1204.160)
  • Auxiliary electrode: Platinum rod (6.0343.000)
  • Reference electrode: Ag/AgCl/KCl (3 M) system with KNO3 intermediate (6.1245.010)
  • Hydrodynamic stirring rate: 2000 rpm
  • Measurement mode: Cyclic voltammetric stripping
  • Calibration technique: Dilution titration
  • Potential sweep: 1.625 V → –0.175 V → 1.625 V, step 6 mV, scan rate 0.1 V/s
  • Evaluation metric: Stripping charge ratio Q/Q(0) set at 0.5

Main Results and Discussion


Cyclic voltammograms exhibit a well-defined copper stripping peak at approximately 0.2 V. Incremental additions of suppressor lead to a proportional decrease in the stripping charge. The dilution titration calibration curve of Q/Q(0) versus suppressor volume displays linear behavior up to 0.40 mL, enabling precise quantification under typical bath conditions.

Benefits and Practical Applications


  • Eliminates complex sample preparation and accelerates analysis time
  • Delivers high selectivity and sensitivity for polymeric suppressors
  • Facilitates routine QA/QC monitoring to maintain stable plating performance

Future Trends and Opportunities


Integration of on-line electrochemical sensors and automated dilution titration modules promises real-time suppressor monitoring and feedback control. Further developments in miniaturized CVS systems and data analytics could enhance process optimization, reduce chemical waste, and support Industry 4.0 initiatives.

Conclusion


The combined cyclic voltammetric stripping and dilution titration method offers a robust, reproducible, and efficient solution for measuring Top Lucina α-M in acid copper baths. Its simplicity and accuracy make it ideally suited for industrial applications in plating process control.

References


  • Okuno Chemical Industries. VA Application Note No. V-182, Version 1.0.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Brightener «Top Lucina α-2» in acid copper baths (Okuno Chemical Industries)
VA Application Note No. V - 183 Title: Brightener «Top Lucina α-2» in acid copper baths (Okuno Chemical Industries) Summary: Determination of brightener «Top Lucina α-2» in acid copper baths by modified linear approximation technique (MLAT) using cyclic voltammetric stripping…
Key words
vertex, vertexelectrode, electrodebaths, bathscvs, cvspotential, potentialcopper, copperokuno, okunoq'intercept, q'interceptmlat, mlatbrightener, brightenerrde, rdeworking, workingelectroplating, electroplatingapproximation, approximationsolution
Determination of leveler «Top Lucina α-3» in acid copper baths by response curve technique (RC) (Okuno Chemical Industries)
VA Application Note No. V - 184 Title: Determination of leveler «Top Lucina α-3» in acid copper baths by response curve technique (RC) (Okuno Chemical Industries) Summary: Determination of leveler «Top Lucina α-3» in acid copper baths by response curve…
Key words
vertex, vertexelectrode, electrodebaths, bathscvs, cvspotential, potentialelectrolyte, electrolytecopper, copperokuno, okunoleveler, levelertechnique, techniquerde, rdeworking, workingelectroplating, electroplatingsolution, solutionshaft
Suppressor «Cupraspeed» in acid copper baths (Atotech)
VA Application Note No. V - 137 Title: Suppressor «Cupraspeed» in acid copper baths (Atotech) Summary: Determination of suppressor «Cupraspeed» in acid copper baths by dilution titration (DT) using cyclic voltammetric stripping (CVS). Sample: Acid copper electroplating bath Sample preparation:…
Key words
cupraspeed, cupraspeedsuppressor, suppressorvertex, vertexcopper, copperelectrode, electrodebaths, bathspotential, potentialatotech, atotechacid, acidrde, rdevoltammetric, voltammetricworking, workingelectroplating, electroplatingvms, vmscvs
Suppressor «Cupracid BL-CT» in acid copper baths (Atotech)
VA Application Note No. V - 135 Title: Suppressor «Cupracid BL-CT» in acid copper baths (Atotech) Summary: Determination of suppressor «Cupracid BL-CT» in acid copper baths by dilution titration (DT) using cyclic voltammetric stripping (CVS). Sample: Acid copper electroplating bath…
Key words
cupracid, cupracidsuppressor, suppressorvertex, vertexcopper, copperelectrode, electrodebaths, bathspotential, potentialatotech, atotechacid, acidrde, rdeworking, workingelectroplating, electroplatingvms, vmscvs, cvsvirgin
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike