Significance of the Topic


The leveler Top Lucina α-3 plays a crucial role in acid copper plating baths by ensuring uniform deposit thickness and preventing defects on plated surfaces.

Objectives and Overview of the Study


This application note presents a method to quantify Top Lucina α-3 using the response curve (RC) technique combined with cyclic voltammetric stripping (CVS). It aims to provide a reliable, rapid assay for quality control in plating processes.

Methodology and Instrumentation


The procedure employs a platinum rotating disk electrode (Pt-RDE) with Ag/AgCl/KCl reference and platinum auxiliary electrodes. Key parameters include:
  • Electrolyte: acid copper bath or virgin make-up solution with CuSO4, H2SO4 and NaCl
  • Working electrode: Pt-RDE at 2000 rpm
  • CVS settings: potential range 1.625 V to -0.175 V, step 0.006 V, sweep rate 0.1 V/s
  • Calibration via RC saturated solutions

Main Results and Discussion


The technique demonstrated a clear stripping peak for copper near 0.2 V, with signal intensity proportional to leveler concentration. The calibration curve exhibited linearity across the tested range, supporting accurate quantification within typical bath concentrations. The method showed good reproducibility and rapid measurement times.

Benefits and Practical Applications of the Method


This approach offers:
  • No sample pretreatment required
  • Fast analysis suitable for in-process monitoring
  • High sensitivity and selectivity for leveler detection

Future Trends and Potential Applications


Adapting this electroanalytical technique for automated inline monitoring and expanding its use to multi-component bath additives represent promising directions. Integration with process control systems and miniaturized electrode designs could enable real-time quality assurance.

Conclusion


The RC-CVS method provides a straightforward, sensitive tool for quantifying Top Lucina α-3 in acid copper baths, enhancing process control in electroplating operations.

Reference


  • Okuno Chemical Industries, Application Note No. V-184, Version 1.0

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Leveler «Thru-Cup EVF-R» in acid copper baths (Uyemura)
VA Application Note No. V - 157 Title: Leveler «Thru-Cup EVF-R» in acid copper baths (Uyemura) Summary: Determination of leveler «Thru-Cup EVF-R» in acid copper baths by response curve technique (RC) using cyclic voltammetric stripping (CVS). Sample: Sample preparation: Acid…
Key words
evf, evfleveler, levelerthru, thrucup, cupcopper, coppervertex, vertexelectrode, electrodebaths, bathspotential, potentialelectrolyte, electrolyteuyemura, uyemuraacid, acidrde, rdeworking, workingelectroplating
Brightener «Top Lucina α-2» in acid copper baths (Okuno Chemical Industries)
VA Application Note No. V - 183 Title: Brightener «Top Lucina α-2» in acid copper baths (Okuno Chemical Industries) Summary: Determination of brightener «Top Lucina α-2» in acid copper baths by modified linear approximation technique (MLAT) using cyclic voltammetric stripping…
Key words
vertex, vertexelectrode, electrodebaths, bathscvs, cvspotential, potentialcopper, copperokuno, okunoq'intercept, q'interceptmlat, mlatbrightener, brightenerrde, rdeworking, workingelectroplating, electroplatingshaft, shaftsolution
Suppressor «Top Lucina α-M» in acid copper baths (Okuno Chemical Industries)
VA Application Note No. V - 182 Title: Suppressor «Top Lucina α-M» in acid copper baths (Okuno Chemical Industries) Summary: Determination of suppressor «Top Lucina α-M» in acid copper baths by dilution titration (DT) using cyclic voltammetric stripping (CVS). Sample:…
Key words
lucina, lucinasuppressor, suppressorcopper, coppervertex, vertextop, topelectrode, electrodebaths, bathscvs, cvspotential, potentialokuno, okunoacid, acidrde, rdeworking, workingelectroplating, electroplatingshaft
Brightener «Thru-Cup EVF-1A» in acid copper baths (Uyemura)
VA Application Note No. V - 156 Title: Brightener «Thru-Cup EVF-1A» in acid copper baths (Uyemura) Summary: Determination of brightener «Thru-Cup EVF-1A» in acid copper baths by modified linear approximation technique (MLAT) using cyclic voltammetric stripping (CVS). Sample: Sample preparation:…
Key words
vertex, vertexelectrode, electrodebaths, bathspotential, potentialcopper, copperuyemura, uyemurasolution, solutionq'intercept, q'interceptmlat, mlatrde, rdeworking, workingelectroplating, electroplatingapproximation, approximationvms, vmscvs
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike