Coupling IC with Mass Spectrometry: Theory and Applications

Presentations |  | Thermo Fisher ScientificInstrumentation
Ion chromatography, IC-MS, IC/MS/MS
Industries
Manufacturer
Thermo Fisher Scientific

Summary

Importance of the Topic


Ion chromatography coupled with mass spectrometry (IC-MS) delivers unparalleled sensitivity and selectivity for ionic species analysis. This approach is vital for environmental water monitoring, pharmaceutical impurity profiling, industrial process control and life-science research, where trace detection and confirmation of ions are required.

Objectives and Overview


This work outlines the theoretical principles of IC-MS coupling and illustrates its practical applications across a range of analytes. Key goals include demonstrating system design, interface strategies, ionization techniques and the advantages of single‐ and triple‐quadrupole mass analyzers for ionic separations.

Methodology and Instrumentation


IC-MS measurements employ high‐pressure, non-metallic pumps feeding electrolytic eluent generators (OH⁻ or H⁺) into a separation column with continuous suppressor regeneration. A degasser and autosampler prepare samples for analysis. The effluent is directed to an atmospheric pressure ionization (API) source—typically electrospray ionization (ESI) for already‐ionized species—before entering the mass spectrometer.
  • Single Quadrupole: MSQ Plus, 17–2000 m/z, self-cleaning ESI source, controlled via Chromeleon or Xcalibur software.
  • Triple Quadrupole: TSQ Quantiva and TSQ Endura, enabling MS/MS with selected reaction monitoring (SRM) for attogram‐level sensitivity and enhanced specificity.
  • Capillary IC: Dionex ICS-5000+ with 0.4 mm columns for low-sample volume applications.

Main Results and Discussion


IC-MS provides improved performance over conductivity detection by combining chromatographic separation with mass-selective detection:
  • Common anions and organic acids were quantified at low μg/L levels using SIM, achieving limits of detection (LODs) between 19 and 191 μg/L on a single quadrupole system.
  • Perchlorate in high-ionic matrices was detected at 125 ppt with MSQ Plus, and sub-ppb to ppq levels (<0.005 μg/L) with TSQ Endura.
  • Separation of small amines, sodium and potassium ions demonstrated quantitative detection at tens to hundreds of μg/L.
  • Arsenic species, oxyhalides (chlorite, bromate, iodate) and haloacetic acids (HAA5 & HAA9) were resolved and confirmed using dual-mode IC and MS/MS, with method detection limits down to 0.02 μg/L for HAA5 and sub-ppb for HAA9.

Benefits and Practical Applications


  • Direct injection of aqueous samples without derivatization simplifies preparation.
  • Metal-free flow paths protect columns and reduce contamination.
  • SIM and SRM modes enable unambiguous identification and quantification, even in complex or high-ionic matrices.
  • IC-MS/MS systems integrate data management for streamlined workflow in QA/QC laboratories and research settings.

Future Trends and Potential Uses


Advances in high-resolution mass analyzers (Orbitrap) and further miniaturization of IC systems will expand untargeted metabolomics, trace contaminant screening and real-time process monitoring. Improved automation and software intelligence will facilitate broader adoption in regulatory compliance, environmental forensics and clinical diagnostics.

Conclusion


Coupling ion chromatography with mass spectrometry offers a robust, versatile platform for ionic analyte analysis. From single quadrupole quantitation to triple quadrupole MS/MS confirmation, IC-MS techniques meet the demanding sensitivity, selectivity and throughput requirements of modern analytical laboratories.

References


  • AN 151: Perchlorate in Environmental Waters Using IC-MS
  • AN 243: Common Anions and Organic Acids Using IC-MS
  • AN 269: ppb Levels of Common Cations and Amines by IC-MS
  • AN 1001: Bisphosphonate Pharmaceuticals and Excipients by Capillary IC-MS
  • Slingsby, R. et al., Dual-Selectivity IC-ESI-MS for Arsenic Species (Am. Lab., 2007)
  • AN 630: EPA Method 557 – Haloacetic Acids and Bromate by IC-MS/MS

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Capillary Ion Chromatography Mass Spectrometry for Trace Environmental Analysis
Leo Jinyuan Wang,1 Jonathan Beck,2 and William C. Schnute1 1 Thermo Fisher Scientific, Sunnyvale, CA, USA; 2Thermo Fisher Scientific, San Jose, CA, USA Executive Summary Capillary IC-MS offers unique chromatographic selectivity for polar analytes and can be used as a…
Key words
desolvation, desolvationcapillary, capillaryesi, esiendothall, endothallsolvent, solventdionex, dionexintensity, intensitymsq, msqcondition, conditionproximity, proximityentrance, entrancethermo, thermoanion, anionegc, egcminutes
Determination of Perchlorate in Environmental Waters by Ion Chromatography Coupled with Electrospray Mass Spectrometry (IC-MS)
Rosanne Slingsby and Chris Pohl Thermo Fisher Scientific, Sunnyvale, CA, USA Introduction Perchlorate has been used as an oxidizer in rockets, munitions, and fireworks since the 1950s, and has been found to cause thyroid dysfunction in humans. The California Department…
Key words
msq, msqperchlorate, perchloratedionex, dionexdiversion, diversionaxp, axpturn, turnmass, masswait, waitchromeleon, chromeleonsuppressor, suppressorspectrometer, spectrometermixed, mixedwater, wateroff, offstart
Determination of Perchlorate in Environmental Waters by Ion Chromatography Coupled with Electrospray Mass Spectrometry (IC-MS)
Rosanne Slingsby and Chris Pohl Thermo Fisher Scientific, Sunnyvale, CA, USA Introduction Perchlorate has been used as an oxidizer in rockets, munitions, and fireworks since the 1950s, and has been found to cause thyroid dysfunction in humans. The California Department…
Key words
msq, msqperchlorate, perchloratedionex, dionexdiversion, diversionaxp, axpturn, turnmass, masswait, waitchromeleon, chromeleonspectrometer, spectrometersuppressor, suppressormixed, mixedwater, wateroff, offstart
EASUMMIT: The Value of Ion Chromatography to Environmental Analysis
The Value of Ion Chromatography to Environmental Analysis Jonathan Beck, Ph.D. Thermo Fisher Scientific The world leader in serving science Outline • Introduction to IC-MS/MS • IC-MS analysis of Perchlorate • IC-MS/MS analysis of Haloacetic Acids • IC-MS/MS analysis of…
Key words
superato, superatotsq, tsqperchlorate, perchloratedirezione, direzionecampione, campioneveritas, veritaslaboratorio, laboratorioconfidential, confidentialhaloacetic, haloaceticwater, wateraltis, altisdrinking, drinkingdbcaa, dbcaabdcaa, bdcaatbaa
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike