Analysis of Personal Care Products by Ion Chromatography
Applications | 1997 | Thermo Fisher ScientificInstrumentation
Ion chromatography offers a powerful alternative to traditional HPLC-UV methods for the analysis of nonchromophoric anions and organic acids commonly found in personal care products. It enables simultaneous detection of both inorganic anions and organic acids without derivatization, streamlines workflows in dental care, hair care, and dermatological formulations, and improves reproducibility and throughput in quality control and research laboratories.
This application note demonstrates the use of Dionex ion chromatography to quantify fluoride, monofluorophosphate, polyphosphates, salicylate, thioglycolate, and a range of organic acids in toothpaste, hair perm lotions, and acne medications. It evaluates gradient and isocratic separations on various IonPac columns to establish rapid, single-run methods.
The study employs a Dionex DX-500 IC system with a GP40 pump, ED40 conductivity detector, AD20 absorbance detector, and ASRS suppressor in recycle or external water mode. The primary separation uses an IonPac AS11 column with a hydroxide gradient (0.5–38 mM) at 2.0 mL/min. Alternative methods utilize the AS12A column for isocratic carbonate/hydroxide separations and the ICE-AS6 column for heptafluorobutyric acid ion-exclusion. Eluents are prepared from Type I water and sodium hydroxide, degassed and pressurized for optimal reproducibility.
Ion chromatography with IonPac columns provides a versatile, high-performance platform for comprehensive anion and organic acid analysis in personal care formulations. Its ability to deliver rapid, accurate, and reproducible results supports quality control, regulatory compliance, and research across dental, hair, and dermatological products.
Ion chromatography
IndustriesOther
ManufacturerThermo Fisher Scientific
Summary
Significance of the Topic
Ion chromatography offers a powerful alternative to traditional HPLC-UV methods for the analysis of nonchromophoric anions and organic acids commonly found in personal care products. It enables simultaneous detection of both inorganic anions and organic acids without derivatization, streamlines workflows in dental care, hair care, and dermatological formulations, and improves reproducibility and throughput in quality control and research laboratories.
Objectives and Study Overview
This application note demonstrates the use of Dionex ion chromatography to quantify fluoride, monofluorophosphate, polyphosphates, salicylate, thioglycolate, and a range of organic acids in toothpaste, hair perm lotions, and acne medications. It evaluates gradient and isocratic separations on various IonPac columns to establish rapid, single-run methods.
Methodology and Instrumentation
The study employs a Dionex DX-500 IC system with a GP40 pump, ED40 conductivity detector, AD20 absorbance detector, and ASRS suppressor in recycle or external water mode. The primary separation uses an IonPac AS11 column with a hydroxide gradient (0.5–38 mM) at 2.0 mL/min. Alternative methods utilize the AS12A column for isocratic carbonate/hydroxide separations and the ICE-AS6 column for heptafluorobutyric acid ion-exclusion. Eluents are prepared from Type I water and sodium hydroxide, degassed and pressurized for optimal reproducibility.
Main Results and Discussion
- Efficient separation of 17 organic acids and inorganic anions on AS11 using a hydroxide gradient.
- Simultaneous quantification of fluoride, monofluorophosphate, polyphosphates, chloride, and sulfate in toothpaste.
- Analysis of salicylic acid and excipient anions in acne medication, demonstrating superior detection of nonchromophoric ions with conductivity compared to UV.
- Determination of thioglycolate in hair perm solutions with 96% recovery and 1.8% RSD.
- Isocratic separation on AS12A for simplified analysis of fluoride, MFP, and common anions.
- Selective profiling of organic acids on ICE-AS6 through ion-exclusion, avoiding early elution of inorganic anions.
Benefits and Practical Applications
- Single-run analysis of chromophoric and nonchromophoric analytes without derivatization.
- High efficiency and solvent compatibility of AS11 enable robust separations in complex matrices.
- Improved reproducibility over titration or ion-selective electrode methods.
- Flexible workflow: initial screening on AS11 followed by targeted separations on AS12A or ICE-AS6.
Future Trends and Potential Applications
- Coupling IC with mass spectrometry for enhanced sensitivity and structural information.
- Development of novel suppressor technologies to reduce background noise.
- Application of IC methods to broader consumer products, including cosmetics and food additives.
- Automation of sample preparation and data processing for high-throughput environments.
Conclusion
Ion chromatography with IonPac columns provides a versatile, high-performance platform for comprehensive anion and organic acid analysis in personal care formulations. Its ability to deliver rapid, accurate, and reproducible results supports quality control, regulatory compliance, and research across dental, hair, and dermatological products.
References
- Official Journal of the European Communities, 1983, No. L 291/37–40.
- Borissova R.; Debouki A.; Nikolov T. Fresenius’ J. Anal. Chem. 1993, 347, 63–66.
- Hattab J. Dent. 1989, 17, 77–83.
- Cavrini V.; Andrisano V.; Gatti R.; Scapini G. Int. J. Cosmet. Sci. 1990, 12, 141–150.
- Irache J.M.; Ezpeleta I.; Vega F.A. Chromatographia 1993, 35, 232–236.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Ions In Physiological Fluids
1995|Thermo Fisher Scientific|Applications
Application Note 107 Ions In Physiological Fluids INTRODUCTION Ion chromatography (IC) has gained wide acceptance over the last twenty years. Advances in column technology and detection schemes have led to ion chromatography applications in a wide variety of matrices and…
Key words
aconitate, aconitatesodium, sodiumamount, amountacid, acidoxalate, oxalateanions, anionsisocitrate, isocitratephysiological, physiologicalpotassium, potassiumchloride, chlorideminutes, minuteseluent, eluentphosphate, phosphatesulfate, sulfateautosuppression
Determination of Organic Acids in Fruit Juices and Wines by High-Pressure IC
2013|Thermo Fisher Scientific|Applications
Lillian Chen, Brian De Borba, and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA Key Words Dionex IonPac AS11-HC-4 µm Column, Suppressed Conductivity, Grape Juice, Apple Juice, Pomegranate Juice Introduction Organic acids play important roles in juices and wines because…
Key words
juices, juicesjuice, juiceacid, acidacids, acidsgrape, grapeorganic, organicpomegranate, pomegranatedionex, dionextartrate, tartratemalate, malatesodium, sodiumwines, winesfruit, fruitgalacturonate, galacturonatemerlot
Quantification of Anions in Pharmaceuticals
2002|Thermo Fisher Scientific|Applications
Application Note 116 Quantification of Anions in Pharmaceuticals INTRODUCTION The United States Food and Drug Administration (U.S. FDA)1–3 and regulatory agencies in other countries require that pharmaceutical products be tested for composition to verify their identity, strength, quality, and purity,…
Key words
inactive, inactivesaccharin, saccharinautosuppression, autosuppressionbromide, bromideingredients, ingredientsrecycle, recyclecitrate, citratemultisymptom, multisymptombenzoate, benzoateflu, fluchloride, chlorideanions, anionsfluoride, fluoridesuppressant, suppressantnitrate
Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities
2016|Thermo Fisher Scientific|Brochures and specifications
Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities The power to increase productivity RFIC System Technology Since the introduction of eluent generation in 1998, Thermo Fisher Scientific has continued to simplify ion chromatography (IC) while expanding the capabilities and…
Key words
eluent, eluentrfic, rficdionex, dionexcarbonate, carbonatekoh, kohgeneration, generationsuppressor, suppressorelectrolytically, electrolyticallyregenerated, regeneratedhydroxide, hydroxideegc, egcsystems, systemsconductivity, conductivityminutes, minutescartridge