Characterization of Poly(isopropyl methacrylate)
Applications | 2023 | Agilent TechnologiesInstrumentation
Characterizing poly(isopropyl methacrylate) by size-exclusion chromatography (SEC) provides critical insights into polymer molecular weight distribution, polydispersity, and structural properties. This information underpins polymer quality control in industrial and research settings, impacting material performance, processing behavior, and end-use applications.
This application note outlines a standardized SEC procedure for poly(isopropyl methacrylate) using tetrahydrofuran (THF) as the mobile phase and PSS SDV columns. The goals are to demonstrate method reproducibility, define sample preparation guidelines, and establish calibration protocols for accurate molar mass determination.
A calibrated analytical setup was employed with the following parameters:
Sample concentration recommendations:
Column sets based on molecular weight range:
The method achieved sharp elugrams with baseline separation of polymer fractions across a broad molar mass span. Calibration with PMMA standards yielded linear relationships between retention time and log(molar mass). Refractive index detection provided sensitive quantification, enabling reliable determination of number-average and weight-average molecular weights.
This SEC protocol offers:
Applications include polymer synthesis monitoring, process control, and comparative analysis of material batches.
Advancements in multi-detector SEC (e.g., light scattering, viscometry) will enhance absolute molecular weight and structural characterization. Integration of high-throughput autosamplers and automated data processing will streamline polymer analysis. Emerging green solvents and novel stationary phases may broaden the technique’s environmental compatibility and resolution capabilities.
The outlined SEC method provides a robust framework for the characterization of poly(isopropyl methacrylate). With defined instrumentation, calibration standards, and sample preparation guidelines, laboratories can achieve consistent, high-resolution molar mass determinations, supporting quality control and research applications.
No specific literature references were provided in the original document.
Consumables, LC columns, GPC/SEC
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies
Summary
Importance of the Topic
Characterizing poly(isopropyl methacrylate) by size-exclusion chromatography (SEC) provides critical insights into polymer molecular weight distribution, polydispersity, and structural properties. This information underpins polymer quality control in industrial and research settings, impacting material performance, processing behavior, and end-use applications.
Objectives and Overview
This application note outlines a standardized SEC procedure for poly(isopropyl methacrylate) using tetrahydrofuran (THF) as the mobile phase and PSS SDV columns. The goals are to demonstrate method reproducibility, define sample preparation guidelines, and establish calibration protocols for accurate molar mass determination.
Methodology and Instrumentation
A calibrated analytical setup was employed with the following parameters:
- Mobile phase: Tetrahydrofuran at 1.00 mL/min
- Column: PSS SDV series, thermostatted at 25 °C
- Detector: Refractive Index (Shodex RI-71)
- Calibration standard: ReadyCal-Kit Poly(methyl methacrylate)
- Data analysis: PSS WinGPC software
Sample concentration recommendations:
- Narrow polydispersity (PDI ≤ 1.5): 2 g/L for 100–10 000 Da, 1–2 g/L for 10 000–1 000 000 Da, ≤ 0.5 g/L above 1 000 000 Da
- Broad polydispersity (PDI > 1.5): 3–5 g/L across all molar mass ranges
- Injection volume: 100 µL
Column sets based on molecular weight range:
- Low (100–50 000 Da): P/N 201-0001 or sda083003lis
- Medium (50 000–500 000 Da): P/N 201-0002 or sda083005lim
- High (500 000–5 000 000 Da): P/N 201-0003 or sda083005lxl
- Ultra-high (> 5 000 000 Da): P/N 202-0001
Main Results and Discussion
The method achieved sharp elugrams with baseline separation of polymer fractions across a broad molar mass span. Calibration with PMMA standards yielded linear relationships between retention time and log(molar mass). Refractive index detection provided sensitive quantification, enabling reliable determination of number-average and weight-average molecular weights.
Benefits and Practical Applications
This SEC protocol offers:
- Reproducible molar mass distribution profiles for R&D, quality assurance, and material certification
- Scalable sample concentration guidelines to optimize signal-to-noise ratios
- Column selection flexibility to address diverse polymer size ranges
Applications include polymer synthesis monitoring, process control, and comparative analysis of material batches.
Future Trends and Applications
Advancements in multi-detector SEC (e.g., light scattering, viscometry) will enhance absolute molecular weight and structural characterization. Integration of high-throughput autosamplers and automated data processing will streamline polymer analysis. Emerging green solvents and novel stationary phases may broaden the technique’s environmental compatibility and resolution capabilities.
Conclusion
The outlined SEC method provides a robust framework for the characterization of poly(isopropyl methacrylate). With defined instrumentation, calibration standards, and sample preparation guidelines, laboratories can achieve consistent, high-resolution molar mass determinations, supporting quality control and research applications.
References
No specific literature references were provided in the original document.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Characterization of Poly(ethyl methacrylate)
2023|Agilent Technologies|Applications
Errata Notice This document contains references to PSS or Polymer Standards Service. Please note that PSS is now Agilent. This document will be republished as an Agilent document in the future. # 10042 - Column Application Note Characterization of Poly(ethyl…
Key words
pss, psssdv, sdvfax, faxmail, mailphone, phonemethacrylate, methacrylatepoly, polyweb, webdocument, documentpolymer, polymerreadycal, readycalelugram, elugramrepublished, republishederrata, erratarecommandations
Characterization of Poly(n-propyl methacrylate)
2023|Agilent Technologies|Applications
Errata Notice This document contains references to PSS or Polymer Standards Service. Please note that PSS is now Agilent. This document will be republished as an Agilent document in the future. # 10055 - Column Application Note Characterization of Poly(n-propyl…
Key words
pss, psssdv, sdvfax, faxmail, mailphone, phonemethacrylate, methacrylatepoly, polyweb, webdocument, documentpolymer, polymerreadycal, readycalelugram, elugramrepublished, republishederrata, erratarecommandations
Characterization of Poly(methyl methacrylate)
2023|Agilent Technologies|Applications
Errata Notice This document contains references to PSS or Polymer Standards Service. Please note that PSS is now Agilent. This document will be republished as an Agilent document in the future. # 10031 - Column Application Note Characterization of Poly(methyl…
Key words
pss, psssdv, sdvpoly, polypmma, pmmafax, faxmail, mailphone, phonemethacrylate, methacrylatemethyl, methylmethacrylates, methacrylatesweb, webdocument, documentpolymer, polymerreadycal, readycalelugram
Characterization of Poly(n-butyl methacrylate)
2023|Agilent Technologies|Applications
Errata Notice This document contains references to PSS or Polymer Standards Service. Please note that PSS is now Agilent. This document will be republished as an Agilent document in the future. # 10300 - Column Application Note Characterization of Poly(n-butyl…
Key words
pss, psssdv, sdvfax, faxmail, mailphone, phonemethacrylate, methacrylatepoly, polyweb, webbutyl, butyldocument, documentpolymer, polymerrepublished, republishederrata, erratarecommandations, recommandationspdi