CRM Tellurium (Te) - Aqueous calibration solution ASTASOL® AN905910C

Others | 2023 | ANALYTIKAInstrumentation
Standards and chemicals
Industries
Manufacturer
ANALYTIKA

Summary

Significance of the Topic


Accurate calibration solutions underpin reliable quantitative analysis across atomic spectrometry and electroanalytical techniques. Certified reference materials provide metrological traceability, ensure comparability of results, and support method validation in research, quality control, and regulatory compliance.

Objectives and Overview


This certificate describes aqueous calibration solution ASTASOL® AN905910C containing tellurium at a certified concentration of 10000 mg/L. It outlines production, certification, homogeneity, stability, and intended analytical applications.

Methodology and Instrumentation


  • Gravimetric preparation using ultra-pure Te metal (99.999 %) for direct SI-traceable concentration.
  • Concentration verification by inductively coupled plasma optical emission spectrometry (ICP-OES).
  • Cross-validation against independent SRM NIST 3156 tellurium standard.
  • Trace impurity profiling by atomic absorption spectrometry (AAS), ICP-OES, and inductively coupled plasma mass spectrometry (ICP-MS).

Main Results and Discussion


The solution exhibits a certified tellurium concentration of 10000 ± 20 mg/L (expanded uncertainty, k = 2) and density of 1.0785 ± 0.0005 g/cm³ at 20 °C. Trace element levels were all below detection limits, confirming high purity. Homogeneity tests ensured consistent composition across bottles, and stability studies validate a five-year shelf life under recommended storage conditions.

Benefits and Practical Applications


  • Calibration for AAS, AES, ICP-OES, and ICP-MS techniques.
  • Support for molecular absorption and selected electroanalytical methods.
  • SI traceability enhances confidence in quantitative results and compliance with regulatory standards.

Future Trends and Potential Uses


With rising demand for ultra-trace elemental analysis, CRMs like ASTASOL® AN905910C will remain critical for advanced methods such as single-cell elemental profiling and isotope dilution mass spectrometry. Development of matrix-matched and multi-element standards may further expand application scope.

Conclusion


ASTASOL® AN905910C delivers a high-purity, SI-traceable calibration solution for tellurium analysis, combining rigorous certification, stability, and broad applicability. It underpins accurate, reproducible measurements essential for diverse analytical workflows.

Reference


  • ISO Guide 31:2000, Reference Materials – Contents of Certificates and Labels.
  • ČSN EN ISO 17034:2017, General Requirements for the Competence of Reference Material Producers.
  • NIST SRM 3156, Tellurium Standard Solution, National Institute of Standards and Technology.
  • ČSN EN ISO/IEC 17025:2018, General Requirements for the Competence of Testing and Calibration Laboratories.
  • ISO 9001:2016, Quality Management Systems – Requirements.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
CRM Tellurium (Te) - Aqueous calibration solution ASTASOL® AN90591C
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net Analytika, spol. s r.o., Oddělení RM, výrobce RM č. 7501, akreditovaný ČIA podle ČSN EN ISO 17034:2017 Analytika, spol. s r.o., Department of RM, Reference Materials…
Key words
tellurium, telluriumcrm, crmaqueous, aqueousreference, referencecalibration, calibrationbellow, bellowastasol, astasoldeclared, declaredexpiration, expirationsolutions, solutionsanalysing, analysingstoring, storinghomogeneous, homogeneousshelf, shelfguarantees
CRM Tellurium (Te) - Aqueous calibration solution ASTASOL® AN8059C
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net Analytika, spol. s r.o., Oddělení RM, výrobce RM č. 7501, akreditovaný ČIA podle ČSN EN ISO 17034:2017 Analytika, spol. s r.o., Department of RM, Reference Materials…
Key words
crm, crmaqueous, aqueouselectroanalytical, electroanalyticaltellurium, telluriumcalibration, calibrationbellow, bellowastasol, astasoldeclared, declaredexpiration, expirationanalysing, analysingreference, referencehomogeneous, homogeneousstoring, storingshelf, shelfsolutions
CRM Copper (Cu) - Aqueous calibration solution ASTASOL® AN8015N
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net Analytika, spol. s r.o., Oddělení RM, výrobce RM č. 7501, akreditovaný ČIA podle ČSN EN ISO 17034:2017 Analytika, spol. s r.o., Department of RM, Reference Materials…
Key words
crm, crmaqueous, aqueouscalibration, calibrationbellow, bellowastasol, astasoldeclared, declaredexpiration, expirationreference, referenceanalysing, analysingstoring, storinghomogeneous, homogeneoussolutions, solutionsshelf, shelfguarantees, guaranteescopper
CRM Copper (Cu) - Aqueous calibration solution ASTASOL® AN8015C
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net Analytika, spol. s r.o., Oddělení RM, výrobce RM č. 7501, akreditovaný ČIA podle ČSN EN ISO 17034:2017 Analytika, spol. s r.o., Department of RM, Reference Materials…
Key words
crm, crmaqueous, aqueouscalibration, calibrationbellow, bellowastasol, astasoldeclared, declaredexpiration, expirationreference, referenceanalysing, analysingstoring, storinghomogeneous, homogeneoussolutions, solutionsshelf, shelfguarantees, guaranteescopper
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike