Orbitrap Ascend BioPharma Tribrid mass spectrometer - Product specifications
Brochures and specifications | 2024 | Thermo Fisher ScientificInstrumentation
Accurate and detailed analysis of biotherapeutic molecules is crucial for advancing drug development, ensuring product safety, and meeting regulatory requirements. High-resolution mass spectrometry plays a key role in protein characterization, peptide mapping, and quality control in biopharma.
This article summarizes the design, features, and performance of the Thermo Scientific Orbitrap Ascend BioPharma Tribrid mass spectrometer. It highlights improvements in sensitivity, scan speed, fragmentation versatility, and native protein analysis to address the evolving demands of biotherapeutic and native mass spectrometry workflows.
The Orbitrap Ascend BioPharma Tribrid combines advanced hardware and software innovations. Key components include:
The system achieves high throughput and sensitivity with data-dependent acquisition rates up to 45 Hz in the Orbitrap and 50 Hz in the ion trap. External calibration provides <3 ppm mass accuracy, while internal calibration yields <1 ppm drift over 24 hours. The combination of active ion management and improved vacuum technology enhances detection limits for peptides, oligonucleotides, and intact proteins. Real-Time Search and TurboTMT modes accelerate TMT quantification workflows, improving both coverage and quantitation accuracy.
Advancements may include integration of machine learning for real-time method optimization, expansion of native MS to larger complexes, higher repetition-rate laser photodissociation, and cloud-based data processing. Continued hardware evolution will likely push resolution and speed boundaries, supporting multi-omics strategies and personalized medicine diagnostics.
The Orbitrap Ascend BioPharma Tribrid mass spectrometer offers a versatile, high-performance platform tailored for modern biopharmaceutical analytics. Its combination of advanced ion management, rapid acquisition, and flexible fragmentation modes addresses the stringent demands of both peptide-based and intact protein studies.
LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap
IndustriesProteomics
ManufacturerThermo Fisher Scientific
Summary
Importance of the Topic
Accurate and detailed analysis of biotherapeutic molecules is crucial for advancing drug development, ensuring product safety, and meeting regulatory requirements. High-resolution mass spectrometry plays a key role in protein characterization, peptide mapping, and quality control in biopharma.
Objectives and Overview
This article summarizes the design, features, and performance of the Thermo Scientific Orbitrap Ascend BioPharma Tribrid mass spectrometer. It highlights improvements in sensitivity, scan speed, fragmentation versatility, and native protein analysis to address the evolving demands of biotherapeutic and native mass spectrometry workflows.
Methodology and Instrumentation
The Orbitrap Ascend BioPharma Tribrid combines advanced hardware and software innovations. Key components include:
- Active Ion Management technology with hyperbolic QR5 segmented quadrupole for enhanced ion transmission and selectivity
- Dual Ion Routing Multipoles for optimized ion capture and dissociation
- Next-generation ultra-high-field Orbitrap analyzer delivering up to 480,000 resolution at m/z 200
- Dual-pressure linear ion trap capable of MSn (n=1–10) with multiple fragmentation options (CID, HCD, ETD/EThcD/ETciD, UVPD, PTCR)
- Native MS mode extending mass detection to m/z 16,000 with quadrupole isolation up to m/z 8,000
- Automated Auto-Ready ion source for hands-free calibration
- Software suite including Xcalibur control, Real-Time Search, Dynamic Maximum Injection Time, Advanced Peak Determination, and application-specific method templates
Main Results and Discussion
The system achieves high throughput and sensitivity with data-dependent acquisition rates up to 45 Hz in the Orbitrap and 50 Hz in the ion trap. External calibration provides <3 ppm mass accuracy, while internal calibration yields <1 ppm drift over 24 hours. The combination of active ion management and improved vacuum technology enhances detection limits for peptides, oligonucleotides, and intact proteins. Real-Time Search and TurboTMT modes accelerate TMT quantification workflows, improving both coverage and quantitation accuracy.
Benefits and Practical Applications
- Shortened gradients and faster scan rates increase sample throughput
- Orthogonal fragmentation capabilities support deep peptide sequencing and complex oligonucleotide analysis
- Comprehensive native MS workflows enable structural characterization of protein complexes
- Automated calibration and method templates reduce setup time and operator workload
- Flexible instrument control permits rapid adaptation to varied biopharma quality control and research applications
Future Trends and Potential Applications
Advancements may include integration of machine learning for real-time method optimization, expansion of native MS to larger complexes, higher repetition-rate laser photodissociation, and cloud-based data processing. Continued hardware evolution will likely push resolution and speed boundaries, supporting multi-omics strategies and personalized medicine diagnostics.
Conclusion
The Orbitrap Ascend BioPharma Tribrid mass spectrometer offers a versatile, high-performance platform tailored for modern biopharmaceutical analytics. Its combination of advanced ion management, rapid acquisition, and flexible fragmentation modes addresses the stringent demands of both peptide-based and intact protein studies.
References
- No external literature references were provided in the source material.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Orbitrap Ascend Structural Biology Tribrid mass spectrometer - Product specifications
2024|Thermo Fisher Scientific|Brochures and specifications
Product specifications | 002857 Mass spectrometry Scale up your native structure analysis Orbitrap Ascend Structural Biology Tribrid mass spectrometer Benefits The Thermo Scientific™ Orbitrap™ Ascend Structural Biology Tribrid™ mass spectrometer Exceptional performance with shorter gradients due to higher MS/MS sensitivity…
Key words
ion, ionorbitrap, orbitrapptcr, ptcretd, etdthermo, thermoscientific, scientificmsn, msnrecommended, recommendedrouting, routinganalyzer, analyzermass, masssource, sourceoptional, optionaldissociation, dissociationisolation
Orbitrap Ascend MultiOmics Tribrid mass spectrometer (Product specifications)
2024|Thermo Fisher Scientific|Brochures and specifications
Product specifications | 002859 Mass spectrometry Scale up your multiomics research Orbitrap Ascend MultiOmics Tribrid mass spectrometer Benefits • • Improved capture of labile compounds while maintaining optimal ion transmission Exceptional performance with shorter gradients due to higher MS/MS sensitivity…
Key words
ion, ionorbitrap, orbitrapthermo, thermoetd, etdmsn, msnscientific, scientificoptional, optionalptcr, ptcrrouting, routingmass, massanalyzer, analyzersource, sourcedissociation, dissociationimproved, improvedtrap
Orbitrap Ascend Tribrid mass spectrometer - Product specifications 
2022|Thermo Fisher Scientific|Brochures and specifications
Product specifications | 001181 Mass spectrometry Scale up your science Orbitrap Ascend Tribrid mass spectrometer Benefits • • • Improved capture of labile compounds while maintaining optimal ion transmission Exceptional performance with shorter gradients due to higher MS/MS sensitivity and…
Key words
ion, ionorbitrap, orbitrapthermo, thermoscientific, scientificetd, etdptcr, ptcrmass, massrouting, routinganalyzer, analyzeroptional, optionalsource, sourcetrap, trapmultipole, multipoleprecursor, precursorascend
Thermo Scientific Orbitrap Eclipse Tribrid Mass Spectrometer - Product Specifications
2019|Thermo Fisher Scientific|Brochures and specifications
PRODUCT SPECIFICATIONS Orbitrap Eclipse Tribrid Mass Spectrometer Go beyond today’s discovery Benefits • Exceptional precursor selectivity and sensitivity with the nextgeneration quadrupole mass filter • Unmatched depth and accuracy of TMT analysis with novel Real-Time Search • High Mass Range…
Key words
ion, ionorbitrap, orbitrapptcr, ptcretd, etdmsn, msnmass, massthermo, thermoscientific, scientifichigh, highanalyzer, analyzerprecursor, precursortrap, trapsource, sourceprecursors, precursorstribrid