Determination of Catecholamines by Agilent Ultivo LC/TQ with an InfinityLab Poroshell 120 Aq‑C18 Column

Applications | 2024 | Agilent TechnologiesInstrumentation
LC/MS, LC/MS/MS, LC/QQQ, Consumables, LC columns
Industries
Clinical Research
Manufacturer
Agilent Technologies

Summary

Significance of the Topic


The quantification of catecholamines—dopamine, epinephrine, norepinephrine and their metabolites—is critical for clinical research, neuroscience and cardiovascular diagnostics. These highly polar neurotransmitters regulate key physiological processes, and accurate measurement in complex biological matrices supports disease monitoring, pharmacokinetic studies and research into stress responses.

Objectives and Study Overview


This application note presents a validated method for simultaneous determination of six catecholamine compounds (3-MT, dopamine, epinephrine, norepinephrine, methoxy­epinephrine and methoxy­norepinephrine) in bovine serum albumin (BSA) matrices. The goals were to achieve baseline separation, high sensitivity and broad linear dynamic range using Agilent’s Ultivo LC/TQ system coupled with an InfinityLab Poroshell 120 Aq-C18 column.

Methodology and Instrumentation


Sample Preparation and Standards:
  • Stock solutions (1,000 ng/mL) of each catecholamine prepared in 0.1% formic acid aqueous solution and serially diluted to 50–5,000 pg/mL.
  • Matrix standards generated by spiking 100 µL of each dilution into 900 µL of 1% BSA in water (0.1% formic acid, 25 mg/mL citric acid), yielding 5–500 pg/mL working solutions.
  • Internal standard solution (10 ng/mL) of isotopically labeled analogs prepared in 0.1% formic acid water.
  • Protein precipitation performed by adding 80 µL of 10% trichloroacetic acid to 200 µL of matrix standard plus 5 µL internal standard, followed by centrifugation and supernatant collection.

Used Instrumentation:
  • Agilent 1260 Infinity II LC with binary pump, high-throughput autosampler and column compartment.
  • Agilent Ultivo LC/TQ mass spectrometer with Jet Stream Technology ion source (positive mode).
  • InfinityLab Poroshell 120 Aq-C18 column (4.6 × 100 mm, 2.7 µm).
  • MassHunter acquisition, qualification and quantification software; low-temperature centrifuge; vortex mixer.

LC Conditions:
  • Mobile phase A: 10 mM ammonium acetate + 0.25 mM ammonium fluoride in water; B: acetonitrile.
  • Gradient from 2% B to 95% B over 7 min; flow rate 0.5 mL/min; column temperature 40 °C; injection volume 25 µL.

MS Conditions:
  • MRM transitions optimized for each analyte and corresponding isotope standard.
  • Capillary voltage 2,000 V; nebulizer gas 45 psi; drying gas 180 °C at 5 L/min; sheath gas 370 °C at 11 L/min.

Results and Discussion


Baseline separation of all six analytes was achieved within a 7 min run time. Calibration curves were linear over 5–500 pg/mL (10–500 pg/mL for epinephrine) with correlation coefficients (R2) above 0.996. Recovery of spiked quality controls ranged from 80% to 120%, demonstrating accuracy and reproducibility in BSA matrices.

Benefits and Practical Applications


This method offers:
  • High sensitivity for low-picogram quantification.
  • Fast analysis with excellent peak shape and resolution.
  • Robust performance in protein-rich matrices.
  • Applicability to clinical research, pharmaceutical development and QA/QC laboratories.

Future Trends and Potential Applications


Advances may include automated sample preparation, further miniaturization of flow rates for enhanced sensitivity, and extension to real clinical matrices such as plasma or cerebrospinal fluid. Integration with high-throughput workflows and application to broader panels of polar metabolites will expand utility.

Conclusion


The Agilent Ultivo LC/TQ system combined with the InfinityLab Poroshell 120 Aq-C18 column provides a rapid, sensitive and reliable approach for catecholamine quantification in biomatrix simulations. Its wide dynamic range and robust performance support diverse applications in research and diagnostics.

Reference


1. Fu R.-J.; Wei T.-C. Analysis of Polar Compounds Using an Agilent InfinityLab Poroshell 120 Aq-C18 Column with Improved and Reliable Performance. Agilent Technologies Application Note, publication 5994-5555EN, 2022.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Urinary Catecholamines, Metanephrines, and 3-Methoxytyramine in a Single LC/MS/MS Run
Urinary Catecholamines, Metanephrines, and 3-Methoxytyramine in a Single LC/MS/MS Run Using Agilent Bond Elut Plexa SPE, 1290 Infinity LC, and 6460 Triple Quadrupole LC/MS Application Note Clinical Research Authors Abstract Linda Côté and Christophe Deckers We developed a highly sensitive…
Key words
metanephrine, metanephrineepinephrine, epinephrinenorepinephrine, norepinephrinenormetanephrine, normetanephrinedopamine, dopaminenmol, nmolresponses, responsesintraday, intradayconcentration, concentrationfree, freetotal, totalrelative, relativeboronate, boronateurine, urineagilent
Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS
Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS
2016|Agilent Technologies|Applications
Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SampliQ WCX SPE, 1290 Infinity LC, and 6460 Triple Quadrupole LC/MS Application Note Clinical Research Authors Abstract Linda Côté and Christophe Deckers We developed a highly sensitive and specific LC/MS/MS method to…
Key words
normetanephrine, normetanephrinemetanephrine, metanephrineplasma, plasmawere, wereagilent, agilentefficiencies, efficienciesanalytes, analytesday, dayspect, spectext, extmetanephrines, metanephrinesspe, spenitrogen, nitrogenepinephrine, epinephrineextraction
Plasma Catecholamines by LC/MS/MS
Plasma Catecholamines by LC/MS/MS
2016|Agilent Technologies|Applications
Plasma Catecholamines by LC/MS/MS Using Agilent Captiva NDLipids, BondElut PBA SPE, 1290 Infinity LC, and 6460 Triple Quadrupole LC/MS Application Note Clinical Research Authors Abstract Linda Côté and Christophe Deckers We developed a highly sensitive and specific LC/MS/MS method to…
Key words
epinephrine, epinephrinedopamine, dopaminenorepinephrine, norepinephrineagilent, agilentplasma, plasmaefficiencies, efficienciesndlipids, ndlipidswere, wereresponses, responsesextracted, extractedchromsystems, chromsystemsext, extnitrogen, nitrogencatecholamines, catecholaminesnmol
Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ
Application Note Clinical Research Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ Abstract Authors Jennifer Hitchcock , Lauren Frick2, Peter Stone1, and Vaughn Miller2 1 1 Agilent Technologies, Inc. Santa Clara, CA 2 Agilent Technologies, Inc.…
Key words
average, averagelinear, linearquadratic, quadraticcarbamazepine, carbamazepinevigabatrin, vigabatrintiagabine, tiagabinelevetiracetam, levetiracetamavg, avgretigabine, retigabinerufinamide, rufinamidelacosamide, lacosamidefelbamate, felbamateoxcarbazepine, oxcarbazepinepregabalin, pregabalinacetylretigabine
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike