FlipLCTM. Measuring Charged Analytes in Complex Mixtures. Part IV. Metabisulfite

Applications | 2018 | SIELCInstrumentation
HPLC, Consumables, LC columns
Industries
Other
Manufacturer
SIELC

Summary

Importance of the Topic


Charged analytes such as metabisulfite occur in complex food matrices where co-eluting compounds interfere with accurate quantitation.
The ability to rapidly isolate and measure these species without extensive sample cleanup is critical for quality control and regulatory compliance in food analysis.

Objectives and Study Overview


This study introduces FlipLCTM, a dual-column HPLC technique designed to simplify chromatograms and enhance detection of charged analytes in complex mixtures.
The focus is on measuring sodium metabisulfite (E223) in red wine as a representative challenging sample.

Methodology


The FlipLC workflow uses two mixed-mode columns in series: an analytical column for separation and an isolation (flip) column to retain interferents.
A valve switch reverses flow through the isolation column at a predetermined time, allowing selective elution of the target analyte.
The method operates isocratically to deliver analysis times under five minutes and reduce column fouling.

Used Instrumentation

  • Analytical column: Primesep SB (4.6 × 150 mm)
  • Isolation (flip) column: Primesep 100 (4.6 × 50 mm)
  • Mobile phase: Gradient from H2O/MeCN/H3PO4 (10/90/0.2) to (50/50/0.5) over 5 minutes, 8-minute hold
  • Flow rate: 1.0 mL/min
  • Detection: UV at 270 nm
  • Injection volume: 10 µL filtered red wine

Main Results and Discussion


Comparison of conventional UV-HPLC and FlipLCTM shows that:
  • Standard chromatogram exhibits multiple overlapping peaks that obscure the metabisulfite signal.
  • FlipLCTM produces a simplified profile with a distinct, well-resolved metabisulfite peak.
  • The isolation column effectively removes matrix interferences, enabling isocratic operation and faster run times.
  • Analytical column lifetime is extended due to reduced exposure to contaminants.

Benefits and Practical Applications

  • Single-method analysis of charged analytes across diverse matrices without bespoke sample cleanup.
  • Reduced analysis time (<5 minutes) increases sample throughput.
  • Enhanced column longevity lowers operational costs.
  • Elimination of ion-pair reagents simplifies mobile phase preparation.

Future Trends and Potential Applications


FlipLCTM’s mixed-mode column approach may be extended to:
  • Other polar and charged food additives, natural products, and biological samples.
  • Environmental monitoring of anionic pollutants.
  • High-throughput QC workflows in pharmaceutical and biotech industries.
  • Automation and coupling with mass spectrometry for enhanced selectivity.

Conclusion


FlipLCTM offers a versatile, rapid, and robust solution for analyzing charged analytes in complex samples.
Its dual-column design effectively isolates target compounds, simplifies chromatograms, shortens run times, and prolongs column life.
This method stands to streamline analytical workflows and broaden the scope of single-method assays across multiple industries.

References

  • No formal literature references were provided in the original text.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
FlipLC Polar molecules in complex samples
FlipLC Polar molecules in complex samples
|SIELC|Brochures and specifications
F. 847-655-6079 www.sielc.com P. 847-229-2629 [email protected] Wheeling, IL 60090 USA SIELC Technologies, Inc. From autosampler 4 5 3 6 2 1 To waste Detector FlipLC Polar molecules in complex samples From autosampler 4 5 3 6 2 1 To waste…
Key words
primesep, primesepfliplc, fliplccolumn, columnwaste, wasteautosampler, autosamplerexamples, examplesmin, minactuation, actuationflip, flipserotonin, serotonindetector, detectoreluted, elutedvalve, valveisolation, isolationfrom
FlipLCTM. A New Method for Measuring Charged Analytes in Complex Mixtures. Part III.
​ ​SIELC Technologies, Inc. Wheeling, IL, USA www.sielc.com​ Ph. ​847-229-2629 FlipLC​TM​. A New Method for Measuring Charged Analytes in Complex Mixtures. Part III. We recently reported a new method that was developed for the analysis of charged analytes in complex…
Key words
plant, plantcornelian, cornelianrimesep, rimeseprosehips, rosehipsblackcurrant, blackcurranttangerine, tangerinehorseradish, horseradishcharged, chargedsource, sourcecabbage, cabbagecherry, cherryflip, flipgrapefruit, grapefruitstrawberry, strawberrylemon
FlipLCTM. A New Method for Measuring Charged Analytes in Complex Mixtures. Part II.
​ ​SIELC Technologies, Inc. Wheeling, IL, USA www.sielc.com​ Ph. ​847-229-262​9 FlipLC​TM​. A New Method for Measuring Charged Analytes in Complex Mixtures. Part II. We recently reported a new method that was developed for the analysis of charged analytes in complex…
Key words
charged, chargedagglomerated, agglomeratedflip, flipwhey, wheyretains, retainsglutamine, glutaminerecently, recentlyingredients, ingredientsconsists, consistsamong, amongwhich, whichisolation, isolationassay, assayconnected, connectedreported
FlipLCTM. A New Method for Measuring Charged Analytes in Complex Mixtures. Part I.
​ ​SIELC Technologies, Inc. Wheeling, IL, USA www.sielc.com​ Ph. ​847-229-262​9 FlipLC​TM​. A New Method for Measuring Charged Analytes in Complex Mixtures. Part I. Measuring by HPLC a particular component of complex samples such as natural products, body fluids, environmental probes…
Key words
grocery, grocerystore, storewatermelon, watermelongarden, gardenpellegrino, pellegrinobologna, bolognafrom, fromcharged, chargedmelon, melonsausages, sausagesproposing, proposingactuated, actuatedlettuce, lettucesan, sanapple
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike