Clarity Control Module SYKAM S4300 AMINO ACID ANALYZER

Manuals | 2024 | DataApexInstrumentation
Software, HPLC
Industries
Proteomics
Manufacturer
DataApex

Summary

Significance of the topic


Automation of post‐column derivatization is essential for reliable amino acid quantitation. The Sykam S4300 Reaction Module integrates a temperature‐controlled reactor, dual‐wavelength detection and a self‐priming pump, enhancing throughput and data consistency. Direct software control enables seamless method management and full chromatogram documentation.

Objectives and Overview


This manual describes how to configure the Sykam S4300 Reaction Module within the Clarity chromatography station. It outlines hardware prerequisites, wiring procedures, software integration steps, method parameter definitions and troubleshooting guidelines.

Methodology and Instrumentation


The Sykam S4300 interfaces with Clarity via RS232 serial communication. Key components include:
  • Post‐column reaction thermostat (up to 180 °C) with active cooling
  • Column oven (20 °C–99 °C) with programmable temperature profiling
  • Dual‐wavelength photometric detector (440 nm and 570 nm) with analog outputs
  • Integrated two‐plunger reagent dosing pump (0.01–2.0 mL/min) with pressure monitoring and safety limits
Configuration in Clarity involves adding the reaction module and Colibrick A/D converter, selecting the correct COM port, running connectivity tests and defining detector, pump and temperature settings.

Main Features and Discussion


The module offers:
  • Detector range selection (0.05–2.0 AU), baseline offset adjustments, rise‐time filtering and an autozero function
  • Reagent pump flow control, ninhydrin reaction timing, and programmable maximum/minimum pressure limits for system protection
  • Temperature programming for both the column oven and reactor, including stabilization delays and tolerances
  • Real‐time monitoring of temperature, flow, pressure and reagent volumes with manual wash and stop controls
Advanced logging via COMMDRV.INI supports GLP‐compliant error diagnosis and communication tracing.

Benefits and Practical Applications


Automated control of derivatization and detection streamlines laboratory workflows, reduces manual intervention and ensures reproducible conditions. Integrated safety features such as pressure and volume monitoring enhance instrument uptime and operator safety. Comprehensive method reporting supports QA/QC and regulatory compliance in amino acid analysis.

Future Trends and Potential Applications


Anticipated developments include:
  • Integration with laboratory information management systems (LIMS) for full data traceability
  • Remote monitoring and diagnostics via networked interfaces or cloud platforms
  • Expansion of control modules to support additional derivatization chemistries and broader analyte classes

Conclusion


The Sykam S4300 Reaction Module, when fully integrated with Clarity software, offers a robust and versatile solution for post‐column derivatization in amino acid analysis. Its comprehensive control, safety interlocks and detailed monitoring capabilities support high‐throughput, reproducible methods and facilitate adherence to regulatory standards.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Clarity Control Module SYKAM S32X0 UV/VIS DETECTOR
SYKAM S32X0 UV/VIS DETECTOR Clarity Control Module ENG Code/Rev.: M104/90B Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®,…
Key words
autozero, autozerodetector, detectorclarity, claritydad, dadsykam, sykamdialog, dialogtab, tabpda, pdasignals, signalsstatus, statuscontrol, controlcontents, contentswindow, windowdevice, devicewavelength
Clarity Control Module SYKAM S2100
SYKAM S2100 Clarity Control Module ENG Code/Rev.: M100/100A Date: 2025-05-12 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
idle, idlestandby, standbytable, tablegradient, gradientpump, pumpdialog, dialogflow, flowclarity, clarityrefill, refilloverall, overallstate, statesetup, setuprow, rowtime, timegraph
Clarity Control Module INTERLAB MAESTRO
INTERLAB MAESTRO Clarity Control Module ENG Code/Rev.: M184/90C Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
interlab, interlabmaestro, maestrotab, tabthemethod, themethodmonitor, monitordevice, devicelamp, lampsetup, setupdialog, dialogoff, offdetector, detectorwavelength, wavelengthstandby, standbymaintenance, maintenanceprogram
Clarity Control Module CLUZEAU GECKO 2000
CLUZEAU GECKO 2000 Clarity Control Module ENG Code/Rev.: M128/90B Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex®…
Key words
thermostat, thermostatsetup, setupclarity, claritycluzeau, cluzeauuni, unidialog, dialogtemperature, temperaturetab, tabdataapex, dataapextable, tablecontrol, controlset, setmethod, methoddevice, devicecommunication
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike