Separation of Cationic Surfactants Using Acclaim Surfactant Plus
Applications | 2012 | Thermo Fisher ScientificInstrumentation
Cationic surfactants are integral components in disinfectants, fabric softeners and other industrial formulations. Accurate analysis of these compounds is essential for quality control, environmental monitoring and formulation optimization. However, conventional silica-based HPLC columns often yield broad, asymmetric peaks due to interactions between positively charged surfactants and residual silanol groups on the stationary phase.
This application note evaluates the performance of the Thermo Scientific Acclaim Surfactant Plus column for the separation of seven common cationic surfactants. The study aims to demonstrate improved peak shape, resolution and analysis speed using a single injection method.
Separation was carried out under the following conditions:
The method achieved baseline separation of seven cationic surfactants—lauryl pyridinium, lauryldimethylbenzyl ammonium, octylphenoxyethoxyethyl-dimethylbenzyl ammonium, cetyltrimethylammonium, cetylpyridinium, diethyl heptadecyl imidazolinium and dimethyldihydrogenated tallow ammonium—within 15 minutes. Peaks were symmetrical and well-resolved, indicating minimal secondary interactions and efficient elution.
The Acclaim Surfactant Plus column provides a reliable, fast and high-resolution solution for the analysis of cationic surfactants. Its optimized surface chemistry minimizes ionic interactions, delivering sharp peak shapes and robust performance ideal for diverse analytical settings.
HPLC, LC columns, Consumables
IndustriesEnergy & Chemicals
ManufacturerThermo Fisher Scientific
Summary
Importance of the Topic
Cationic surfactants are integral components in disinfectants, fabric softeners and other industrial formulations. Accurate analysis of these compounds is essential for quality control, environmental monitoring and formulation optimization. However, conventional silica-based HPLC columns often yield broad, asymmetric peaks due to interactions between positively charged surfactants and residual silanol groups on the stationary phase.
Objectives and Overview of the Study
This application note evaluates the performance of the Thermo Scientific Acclaim Surfactant Plus column for the separation of seven common cationic surfactants. The study aims to demonstrate improved peak shape, resolution and analysis speed using a single injection method.
Methodology and Instrumentation
Separation was carried out under the following conditions:
- Column: Acclaim Surfactant Plus, 3 µm, 3.0 × 150 mm
- Mobile phase A: Acetonitrile; Mobile phase B: 100 mM ammonium acetate, pH 5.2
- Gradient: 35 % A from 0 to 8 min, ramp to 85 % A by 15 min
- Flow rate: 0.6 mL/min; Temperature: 30 °C; Injection volume: 5 µL
- Detector: Corona Ultra Charged Aerosol (gain 100 pA; medium filter; nebulizer 20 °C)
Main Results and Discussion
The method achieved baseline separation of seven cationic surfactants—lauryl pyridinium, lauryldimethylbenzyl ammonium, octylphenoxyethoxyethyl-dimethylbenzyl ammonium, cetyltrimethylammonium, cetylpyridinium, diethyl heptadecyl imidazolinium and dimethyldihydrogenated tallow ammonium—within 15 minutes. Peaks were symmetrical and well-resolved, indicating minimal secondary interactions and efficient elution.
Benefits and Practical Applications
- Single-run separation of multiple cationic surfactant classes
- Improved peak shapes and resolution for accurate quantification
- Reduced analysis time and low column bleed enhance throughput
- Robust performance supports routine QA/QC and industrial process monitoring
Future Trends and Potential Applications
- Coupling with mass spectrometry for structural identification and quantitation
- Adaptation to anionic or nonionic surfactant analyses with modified gradients
- High-throughput screening in environmental and wastewater testing
- Integration into automated platforms for continuous process analytics
Conclusion
The Acclaim Surfactant Plus column provides a reliable, fast and high-resolution solution for the analysis of cationic surfactants. Its optimized surface chemistry minimizes ionic interactions, delivering sharp peak shapes and robust performance ideal for diverse analytical settings.
References
- Thermo Fisher Scientific. Separation of Cationic Surfactants Using Acclaim Surfactant Plus. Application Note PB20632_E, 2012.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of Cationic Surfactants on the Acclaim Surfactant Plus HPLC Column
2012|Thermo Fisher Scientific|Applications
D. Foley, W. Faulkner, Thermo Fisher Scientific, Runcorn, Cheshire, UK Key Words Acclaim Surfactant Plus, cationic surfactants, mixed mode chromatography, selectivity Abstract The simultaneous separation of a range of cationic surfactants using a highly selective and robust Thermo Scientific Acclaim…
Key words
surfactant, surfactantacclaim, acclaimsurfactants, surfactantscationic, cationicplus, plusddtmabr, ddtmabrbenzalkonium, benzalkoniumfisher, fishercolumn, columnscientific, scientifichplc, hplcatmabr, atmabrcpycl, cpyclctmabr, ctmabrddpycl
Separation of Alkyl Quaternary Amines Using Acclaim Surfactant Plus with Conductivity Detection
2012|Thermo Fisher Scientific|Applications
Separation of Alkyl Quaternary Amines Using Acclaim Surfactant Plus with Conductivity Detection 10 Column: Thermo Scientific™ Acclaim™ Surfactant Plus, 3.0 µm Dimension: 3.0 × 150 mm System: Thermo Scientific™ Dionex™ ICS-3000™ IC system Mobile phases: A: Acetonitrile B: 100 mM…
Key words
acclaim, acclaimsurfactant, surfactantconductivity, conductivitycationic, cationicsurfactants, surfactantsplus, plussubtraction, subtractionthermo, thermoscientific, scientificalkyl, alkylamines, aminessuppressed, suppressedquaternary, quaternaryspecifically, specificallydetection
Cationic Surfactants Using Acclaim Surfactant Plus with Suppressed Conductivity Detection
2012|Thermo Fisher Scientific|Applications
Cationic Surfactants Using Acclaim Surfactant Plus with Suppressed Conductivity Detection Columns: 5 2 1 4 5 6 µS 3 Thermo Scientific™ Acclaim™ Surfactant Plus, 3.0 µm Dimensions: 3.0 × 150 mm LC System: Thermo Scientific™ Dionex™ ICS-3000™ IC system Mobile…
Key words
cationic, cationicsurfactants, surfactantsconductivity, conductivitysurfactant, surfactantacclaim, acclaimsuppressed, suppressedplus, plusundesired, undesiredsilanol, silanolsubtraction, subtractionionic, ionicinteractions, interactionsdetection, detectionsilica, silicadifficult
Fabric Softener Using Acclaim Surfactant Plus
2012|Thermo Fisher Scientific|Applications
Fabric Softener Using Acclaim Surfactant Plus Column: 100 pA 0 0 4 8 12 Minutes 16 20 Thermo Scientific™ Acclaim™ Surfactant Plus, 3 µm Dimensions: 3.0 × 150 mm System: Thermo Scientific™ Dionex™ UltiMate™ 3000 RSLC system Mobile Phases A:…
Key words
surfactant, surfactantacclaim, acclaimthermo, thermosoftener, softenerdionex, dionexscientific, scientificfabric, fabricplus, pluscationic, cationiccorona, coronaaerosol, aerosolcomes, comescharged, chargedspecifically, specificallyultra