SICRIT® Plug & Play Soft Ionization

Technical notes | 2018 | PlasmionInstrumentation
GC/MSD, LC/MS
Industries
Manufacturer
Plasmion

Summary

Importance of the topic


The introduction of a flow-through soft plasma ionization method addresses critical limitations in conventional mass spectrometry workflows by decoupling ionization from sample delivery. This innovation enhances sensitivity, broadens the accessible analyte range and enables real-time monitoring of volatile and non-volatile compounds without extensive sample preparation.

Objectives and Overview


This report presents the principles and capabilities of SICRIT® (Soft Ionization by Chemical Reaction in Transfer), a patented cold-plasma ion source designed for seamless integration with existing MS systems. Key aims include demonstrating its operational simplicity, evaluating performance in diverse applications and showcasing rapid, high-sensitivity screening workflows.

Methodology and Instrumentation


SICRIT® generates reagent ions within a capillary‐confined cold plasma, decoupling the ionization event from chromatographic or direct sampling interfaces. Sample molecules drawn into the MS inlet are soft ionized in a continuous flow, minimizing ion losses and neutralization. The core instrument package comprises the SC-20X Ionization Set, a dedicated control unit and modular interfaces for major LC-MS platforms, as well as an optional GC/SPME module for gas-phase analyses.

Key Results and Discussion


  • Online VOC screening of coffee bean aroma identified over 300 compounds in under one second, demonstrating real-time monitoring capability.
  • GC-MS coupling with SICRIT® achieved detection of 28 pesticides in water at limits down to 30 pg/mL, highlighting sub-ppt sensitivity for target and non-target analysis.
  • Direct SPME-MS application enabled detection of illicit drugs with limits as low as 0.3 pg/mL, eliminating the need for chromatographic separation for rapid workflows.
These case studies confirm enhanced sensitivity, broad chemical coverage and easy adaptation to various sampling formats.

Benefits and Practical Applications


  • Plug-and-play installation on all major LC-MS systems without ionization tuning or sample prep.
  • Compatibility with LC, GC and SPME workflows for flexible analytical design.
  • Sub-ppt detection limits support trace analysis in environmental monitoring, food safety, security, forensics and breath diagnostics.
  • Transformation of MS instruments into sensitive electronic noses for Industry 4.0 and emission monitoring applications.

Future Trends and Opportunities


The modular and soft ionization design of SICRIT® opens prospects for portable MS systems in field analysis, automated process control in manufacturing and integration with advanced sample pretreatment (e.g., microextraction devices). Further development may focus on miniaturized plasma sources, real-time multivariate data analysis and expansion into clinical metabolomics.

Conclusion


SICRIT® represents a paradigm shift in MS ionization, delivering unmatched sensitivity and flexibility. By uncoupling ionization from sample introduction, it facilitates rapid, high-throughput screenings and real-time monitoring across diverse matrices, expanding the analytical potential of existing mass spectrometers.

Used Instrumentation


  • SC-20X Ionization Set with integrated control unit
  • Interfaces for Thermo, Agilent and Sciex LC-MS platforms
  • GC/SPME Module for gas chromatography coupling and automated SPME desorption

Reference


  • Pesticide GC-MS analysis, Analyst 2017, 142, 1909
  • SPME-MS drug screening, Analytical Chemistry 2016, 88, 7252

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Direct MS Screening
Direct MS Screening
2020|Plasmion|Presentations
Plasmion GmbH Am Mittleren Moos 48, 86167 Augsburg Tel.: +49 821 2071 3355 Mail: [email protected] Web: www.plasmion.de Dr. Jan-Christoph Wolf Direct MS Screening Get results faster with SICRIT® 04.05.2020 Technology The patented flow-through geometry of the SICRIT® ionization source is…
Key words
sicrit, sicritscreening, screeningquantification, quantificationcoupling, couplingpfca, pfcaionization, ionizationwithout, withoutdirect, directenables, enablesaroma, aromaabundance, abundancelike, likecompounds, compoundsexplosives, explosivesleather
Plasmion SICRIT® Ionization Set SC-30
Plasmion SICRIT® Ionization Set SC-30
2020|Plasmion|Brochures and specifications
Product Note SICRIT® Ionization Set SC-30 The SICRIT® Ionization Set SC-30 upgrades any LC-MS instrument with a plug & play ionization source. The SICRIT® soft ionization technology enables PTR-like online MS-measurements as well as coupling of sample enrichment and/or chromatographic…
Key words
sicrit, sicritsource, sourcesoft, softion, ionplasmion‘s, plasmion‘sionization, ionizationinterfaces, interfacesspme, spmemeasurements, measurementsreserved, reserveddirect, directrights, rightsyour, yourplasma, plasmaoperation
Coffee Aroma Profiling - Direct SICRIT® HR-MS Analysis
Coffee Aroma Profiling - Direct SICRIT® HR-MS Analysis
2019|Thermo Fisher Scientific|Applications
Application Note Coffee Aroma Profiling - Direct SICRIT® HR-MS Analysis Introduction Coffee is one of the most popular beverages and known for its manifold aroma profiles. Aroma is one of the first senses experienced when preparing or consuming a coffee…
Key words
sicrit, sicritcoffee, coffeedirect, directroasting, roastingprofiling, profilingaroma, aromabean, beanbeans, beansvocs, vocsreal, realvolatile, volatileroasted, roastedidentified, identifiedreserved, reservedinterfacing
SICRIT ® – The Ion Source for Direct MS Measurements
SICRIT ® – The Ion Source for Direct MS Measurements
2021|Plasmion|Brochures and specifications
SICRIT – The Ion Source for Direct MS Measurements ® Upgrade your MS into a sensitive VOC sensor for fast screening or 24/7 monitoring Simplifying Mass Spectrometry Direct MS has shown its potential for fast screening analysis and for real-time…
Key words
sicrit, sicritdirect, directsource, sourcehoney, honeyabundance, abundanceplasmion‘s, plasmion‘sion, ionplasmion, plasmionrelative, relativeionization, ionizationconnection, connectionenables, enablespal, palsampling, samplingbio
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike