Significance of the Topic


Glucocorticoids such as budesonide play a critical role in anti-inflammatory therapy for asthma, allergic rhinitis, and dermatological conditions. Due to its low oral bioavailability, achieving reliable quantitation of budesonide at low picogram-per-milliliter levels in plasma is essential for accurate pharmacokinetic and bioequivalence assessments.

Objectives and Study Overview


This application note describes the development and validation of a sensitive LC-MS/MS assay using the SCIEX Triple Quad™ 5500+ – QTRAP® Ready system to quantify budesonide in human plasma across a concentration range of 2 to 1024 pg/mL.

Methodology and Experimental Procedures


  • Sample Preparation
    • Human plasma samples (200 µL) spiked with budesonide standards and deuterated internal standard (budesonide-D8).
    • SPE cleanup on Phenomenex Strata-X RP cartridges: conditioning with methanol and water, sample load, wash with 5% methanol, and elution with 100% methanol.
    • Drying under vacuum and reconstitution in 40% acetonitrile for LC injection.
  • Chromatography
    • Column: C18 (100 × 2.1 mm, 1.7 µm) at 50 °C.
    • Mobile phase A: 5 mM ammonium bicarbonate; B: acetonitrile; flow rate 0.5 mL/min.
    • Gradient: 40% B at 0 min to 95% B at 2 min, held to 3 min, returned to 40% B by 4 min.
    • Injection volume: 10 µL.
  • Mass Spectrometry
    • SCIEX Triple Quad™ 5500+ – QTRAP® Ready in positive electrospray ionization.
    • MRM transitions: m/z 431.3→323.2 and 431.3→147.1 for budesonide epimers; 439.3→323.2 for the internal standard.
    • Source settings: curtain gas 30, temperature 600 °C, GS1 = 60, GS2 = 80, ion voltage 3000 V, dwell time 75 ms.
  • Data Processing
    • Acquisition in Analyst® 1.7.1; quantitation via SCIEX OS-Q with 1/x²-weighted linear regression.

Main Results and Discussion


  • Sensitivity and Linearity
    • LLOQ of 2 pg/mL achieved without significant matrix interference.
    • Calibration curve linear from 2 to 1024 pg/mL (r = 0.99).
  • Precision and Accuracy
    • %CV ranged from 1.9% to 12.2%; accuracy between 95% and 106% across the calibration range.
  • Robustness
    • SPE sample cleanup effectively minimized matrix effects.
    • Fast run time (<4 min) and stable performance with Turbo V™ source.

Benefits and Practical Applications


  • High sensitivity supports low-level pharmacokinetic profiling.
  • Wide dynamic range accommodates both therapeutic and trace-level measurements.
  • Rapid sample preparation and chromatographic run increase laboratory throughput.

Future Trends and Opportunities


  • Adoption of high-resolution mass spectrometry for enhanced metabolite confirmation.
  • Automation of SPE workflows to improve consistency and throughput.
  • Expansion toward multiplexed assays for respiratory biomarkers.

Conclusion


This validated LC-MS/MS method delivers selective, sensitive, and high-throughput quantitation of budesonide in human plasma, fulfilling stringent bioanalytical requirements for pharmacokinetic and clinical studies.

Reference


  1. Collins BA, Dima MA, Ivosev G, Zhong F (2013) A high dynamic range pulse counting detection system for mass spectrometry. Rapid Commun Mass Spectrom. 28(2):209–216.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Highly sensitive quantitative analysis of budesonide from plasma using LC/MS/MS
PO-CON1744E Highly sensitive quantitative analysis of budesonide from plasma using LC/MS/MS ASMS 2017 ThP 710 Shailendra Rane1, Ashutosh Shelar1, Shailesh Damale1, Rashi Kochhar1, Purshottam Sutar1, Deepti Bhandarkar1, Anant Lohar1, Ajit Datar1, Pratap Rasam1, Jitendra Kelkar1 and Devika Tupe2 1 Shimadzu…
Key words
budesonide, budesonideplasma, plasmasensitive, sensitivehighly, highlyquantitative, quantitativefrom, fromanalysis, analysisgraph, graphusing, usingaverage, averageconcentration, concentrationcytokines, cytokinesglucocorticoid, glucocorticoidinhibitory, inhibitorycompound
Highly Sensitive LC-MS/MS Method for Quantification of Barnidipine in Human Plasma
Highly Sensitive LC-MS/MS Method for Quantification of Barnidipine in Human Plasma Using the SCIEX QTRAP® 6500+ System with ExionLC™ AD System M Chandrasekar, Dilip Reddy, Manoj Pillai1 SCIEX, India Barnidipine is a long-acting novel calcium antagonist that belongs to the…
Key words
barnidipine, barnidipinecalcium, calciumiondrive, iondriveplasma, plasmamethod, methodassays, assayssensitive, sensitivedihydropyridine, dihydropyridineqjet, qjetantagonist, antagonistvascular, vascularusfda, usfdadhp, dhpreinjection, reinjectioncxp
The Quantitative Power of SCIEX Triple Quad and the QTRAP® 6500+ LC-MS/MS System for the Bioanalysis of Biotherapeutics
For Research Use Only. Not for Use In Diagnostic Procedures. Drug Discovery and Development The Quantitative Power of SCIEX Triple Quad and the QTRAP® 6500+ LC-MS/MS System for the Bioanalysis of Biotherapeutics Featuring the SCIEX Triple Quad™ and QTRAP 6500+…
Key words
lgldfdsfr, lgldfdsfrsggllwqlvr, sggllwqlvrldr, ldryvyvadvaak, yvyvadvaakpeptide, peptidelasvsvr, lasvsvrsaegldasaslr, saegldasaslrllslgagefk, llslgagefkpositive, positivesciex, sciexavyfyapqiplyank, avyfyapqiplyankftisadtsk, ftisadtskvvgglvalr, vvgglvalrnegative, negativeionization
Sub-Picogram Level Quantitation of Desmopressin in Small Volumes of Human Plasma Using a Trap-Elute Microflow
Sub-Picogram Level Quantitation of Desmopressin in Small Volumes of Human Plasma Using a Trap-Elute Microflow Using the QTRAP® 6500+ System with OptiFlow™ Turbo V Source and M5 MicroLC System Rahul Baghla, Khatereh Motamedchaboki, Remco van Soest and Lei Xiong SCIEX,…
Key words
microflow, microflowdesmopressin, desmopressinplasma, plasmaparameter, parameterphase, phaseflow, flowvalue, valuehuman, humanmobile, mobilepicogram, picogramrate, ratesource, sourcesciex, sciexstationary, stationaryexchange
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike