Significance of the Topic


The rapid growth of biopharmaceutical development demands robust analytical platforms capable of precise quantification of protein‐derived analytes in complex biological matrices. Liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) using multiple reaction monitoring (MRM) with peptide surrogates has emerged as a preferred bioanalytical approach due to its high specificity, broad dynamic range, and multiplexing capability.

Objectives and Study Overview


This study assesses the quantitative performance of the SCIEX Triple Quad and QTRAP 6500+ LC-MS/MS systems equipped with an IonDrive Turbo V source and SCIEX OS software. Key aims include:
  • Determining intra-spectrum linear dynamic range and sensitivity using a 6×5 peptide reference mix.
  • Evaluating quantitation of signature peptides spiked into digested rat plasma in both positive and negative ion modes.
  • Comparing limits of quantitation, linearity, accuracy, and precision under real-world sample conditions.

Methodology and Instrumentation


Sample Preparation:
  • 6×5 peptide reference mix diluted in 5% acetonitrile/1% formic acid, injected at 1 pmol to 0.0001× concentration levels.
  • Rat plasma proteins precipitated with cold methanol, trypsin-digested, acidified, and diluted 200× before spiking with synthetic signature peptides.

Chromatography:
  • ExionLC UHPLC with Phenomenex bioZen Peptide XB-C18 column (50×2.1 mm, 2.6 µm).
  • Mobile phases: water + 0.1% formic acid (A) and acetonitrile + 0.1% formic acid (B).
  • Gradient elution over 5–7 min at 500 µL/min, 40 °C column temperature.

Mass Spectrometry:
  • SCIEX Triple Quad and QTRAP 6500+ with IonDrive Turbo V source.
  • Positive and negative MRM transitions optimized for declustering potential, collision energy, and cell exit potential.
  • Data acquired in triplicate and processed with SCIEX OS v1.6.1 using MQ4 peak integration.

Main Results and Discussion


Peptide Reference Mix:
  • All five isotopologues per peptide quantified across four orders of magnitude with R² ≥ 0.999.
  • Signal‐to‐noise enabled detection of the lowest isotopologue at 0.0001×, spanning >5 orders of magnitude.
  • Precision (%CV) remained below 7% at lower levels and under 3% at higher concentrations.

Peptides in Plasma (Positive Mode):
  • Three signature peptides showed linear dynamic ranges up to 5 orders of magnitude (R² > 0.99).
  • Lower limits of quantitation reached 0.009–0.018 ng/mL with %CV ≤ 15%.
  • Accuracy ranged from 87% to 107% across all measured concentrations.

Peptides in Plasma (Negative Mode):
  • Three peptides evaluated in negative ionization achieved up to 4.5 orders of magnitude linearity.
  • LLOQs between 0.0086 and 0.0417 ng/mL with acceptable precision (%CV ≤ 19%).
  • Accuracy remained within 82–113% across calibration points.

Benefits and Practical Applications


• High sensitivity and broad dynamic range enable detection of low-abundance biotherapeutic peptides.
• Multiplexing capability supports simultaneous quantitation of multiple analytes in a single run.
• Robust performance in complex matrices accelerates bioanalytical workflows for pharmacokinetics, immunogenicity, and biomarker studies.
• User-friendly SCIEX OS software streamlines data processing and reporting.

Future Trends and Potential Applications


Advancements in ion source technology and software automation will further enhance throughput and data confidence. Integration of AI-driven data analysis may allow real-time QC alerts and deeper insight into post-translational modifications. Expansion to higher-order biotherapeutic formats, such as antibody-drug conjugates and multi-specific proteins, will benefit from the demonstrated quantitative power.

Conclusion


The SCIEX Triple Quad and QTRAP 6500+ systems deliver exceptional quantitative performance for bioanalysis of peptides in both neat and complex matrices. Their wide linear dynamic range, low LLOQs, high accuracy, and precision make them ideal platforms for addressing bioanalytical challenges in biotherapeutic development.

Reference


  • Ouyang Z. et al. (2012) "Pellet digestion: A simple and efficient sample preparation technique for LC-MS/MS quantification of large therapeutic proteins in plasma." Bioanalysis 4(1): 17–28.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Antibody Drug Conjugate Bioanalysis using the BioBA Solution
Antibody Drug Conjugate Bioanalysis using the BioBA Solution A Robust and Accurate Quantification of Ado-Trastuzumab Emtansine Using the BioBA Solution and the SCIEX QTRAP® 6500+ System Michael Deng and Ian Moore SCIEX, Concord, Canada Key Challenges of Antibody-Drug Conjugate Bioanalysis…
Key words
bioba, biobaiyptngytr, iyptngytrsignature, signaturesurfactant, surfactantemtansine, emtansinedtlmisr, dtlmisrantibody, antibodypeptide, peptidestd, stdado, adoadcs, adcsheterogeneous, heterogeneousbioanalysis, bioanalysisadc, adctrastuzumab
Sensitive and Accurate Quantitation of the Antibody-Drug Conjugate Ado-Trastuzumab Emtansine in Rat Plasma
For Research Use Only. Not For Use In Diagnostic Procedures Drug Discovery and Development Sensitive and Accurate Quantitation of the Antibody-Drug Conjugate Ado-Trastuzumab Emtansine in Rat Plasma High-Sensitivity Bioanalysis of ADC using BioBA with M3 MicroLC and QTRAP® 6500+ LC-MS/MS…
Key words
microflow, microflowbioba, biobatraditional, traditionalado, adosignature, signatureemtansine, emtansinequantitation, quantitationantibody, antibodytrastuzumab, trastuzumabflow, flowtrap, trapplasma, plasmasciex, sciexdrug, drugconjugates
MicroLC-MRM Workflow for Cyclic Peptide Quantitation in Human Plasma
MicroLC-MRMHR Workflow for Cyclic Peptide Quantitation in Human Plasma Featuring the SCIEX TripleTOF® 6600+ System with OptiFlow™ Turbo V Source and M5 MicroLC system Ji Jiang, Rahul Baghla and Lei Xiong SCIEX, Redwood City, California, USA Introduction In biotherapeutics discovery…
Key words
mrmhr, mrmhrmicrolc, microlcdesmopressin, desmopressinbioanalysis, bioanalysisparameter, parameterphase, phasevalue, valuemicroflow, microflowsensitivity, sensitivitymobile, mobilecyclic, cyclicflow, flowworkflow, workflowquantitation, quantitationpreclinical
LC-MS/MS Method for the Quantification of Budesonide in Human Plasma
LC-MS/MS Method for the Quantification of Budesonide in Human Plasma Using the SCIEX Triple Quad™ 5500+ – QTRAP® Ready System Ian Moore1, Rolf Kern2 1 SCIEX, Concord, Ontario 2SCIEX, Redwood City, CA Glucocorticoids are a type of corticosteroid, which are…
Key words
budesonide, budesonidebioanalysis, bioanalysisinhalers, inhalerssensitive, sensitiveaccuracy, accuracyldr, ldrcxp, cxpqtrap, qtrapstrata, stratabioavailability, bioavailabilitydynamic, dynamicplasma, plasmasystem, systemhuman, humantried
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike