Thermo Scientific Endura MD Mass Spectrometer LC-MS for In Vitro Diagnostic Use
Brochures and specifications | 2014 | Thermo Fisher ScientificInstrumentation
Reliable and precise quantitation of low-level analytes is essential in clinical diagnostics, ensuring timely decision-making and patient care. LC-MS has emerged as a gold standard due to its sensitivity, specificity, and robustness for in vitro diagnostic assays, including therapeutic drug monitoring, metabolic profiling, and biomarker analysis.
This application note evaluates the Thermo Scientific Endura MD mass spectrometer as a Class I in vitro diagnostic device. Combined with the Prelude MD HPLC and ClinQuan MD software, the system aims to deliver high sensitivity, quantitative accuracy, and operational ease for clinical laboratories processing limited-volume and low-concentration samples.
Key methodological features include triple quadrupole analysis with ultrafast selected reaction monitoring (SRM) and an optimized ion optics design for enhanced sensitivity and reduced background. Robust ion source exhaust and a neutral blocker extend cleanliness and stability.
The integrated LC-MS solution enhances laboratory efficiency by automating sample cleanup, reducing manual steps, and supporting high-throughput workflows. User-friendly software and hardware design facilitate rapid operator training and compliance with regulatory requirements, making it suitable for clinical research, therapeutic drug monitoring, and routine diagnostics.
As clinical mass spectrometry expands, automation and integration with laboratory information systems (LIMS) will streamline data processing. Emerging applications include multiplex biomarker panels, newborn screening, precision medicine assays, and AI-driven data interpretation. Continued improvements in sensitivity and software will further broaden LC-MS adoption in clinical diagnostics.
The Thermo Scientific Endura MD system, when paired with the Prelude MD HPLC and ClinQuan MD software, provides a robust, sensitive, and easy-to-use LC-MS platform for in vitro diagnostic applications. It meets the demands of clinical laboratories for accurate and reproducible results, supporting a wide range of assays and high-throughput testing.
LC/MS, LC/MS/MS, LC/QQQ
IndustriesClinical Research
ManufacturerThermo Fisher Scientific
Summary
Significance of the Topic
Reliable and precise quantitation of low-level analytes is essential in clinical diagnostics, ensuring timely decision-making and patient care. LC-MS has emerged as a gold standard due to its sensitivity, specificity, and robustness for in vitro diagnostic assays, including therapeutic drug monitoring, metabolic profiling, and biomarker analysis.
Objectives and Study Overview
This application note evaluates the Thermo Scientific Endura MD mass spectrometer as a Class I in vitro diagnostic device. Combined with the Prelude MD HPLC and ClinQuan MD software, the system aims to deliver high sensitivity, quantitative accuracy, and operational ease for clinical laboratories processing limited-volume and low-concentration samples.
Methodology and Instrumentation
Key methodological features include triple quadrupole analysis with ultrafast selected reaction monitoring (SRM) and an optimized ion optics design for enhanced sensitivity and reduced background. Robust ion source exhaust and a neutral blocker extend cleanliness and stability.
Instrumentation
- Thermo Scientific Endura MD triple quadrupole mass spectrometer with ultrafast SRM
- Thermo Scientific Prelude MD HPLC with TurboFlow sample cleanup and parallel-channel operation
- Thermo Scientific Easy-Max NG ion source accommodating HESI and APCI probes (positive/negative modes)
- Thermo Scientific ClinQuan MD software with tiered user access and audit trails for CLIA compliance
Main Results and Discussion
- Precision: less than 3% relative standard deviation (RSD) across five injections of tacrolimus, sirolimus, and cyclosporine A at multiple concentrations.
- Robustness: over 1200 injections of alprazolam in synthetic serum yielded an average concentration of 12.6 ng/mL with 2.02% RSD, demonstrating stable performance.
- Sensitivity: accurate quantitation of clomipramine at a 1 ng/mL limit of quantitation, with clear SRM transitions and calibration linearity.
- Specificity: sensitive detection of ethyl sulfate and ethyl glucuronide in urine, confirming quantifying and confirming ion transitions with minimal background interference.
Benefits and Practical Applications
The integrated LC-MS solution enhances laboratory efficiency by automating sample cleanup, reducing manual steps, and supporting high-throughput workflows. User-friendly software and hardware design facilitate rapid operator training and compliance with regulatory requirements, making it suitable for clinical research, therapeutic drug monitoring, and routine diagnostics.
Future Trends and Applications
As clinical mass spectrometry expands, automation and integration with laboratory information systems (LIMS) will streamline data processing. Emerging applications include multiplex biomarker panels, newborn screening, precision medicine assays, and AI-driven data interpretation. Continued improvements in sensitivity and software will further broaden LC-MS adoption in clinical diagnostics.
Conclusion
The Thermo Scientific Endura MD system, when paired with the Prelude MD HPLC and ClinQuan MD software, provides a robust, sensitive, and easy-to-use LC-MS platform for in vitro diagnostic applications. It meets the demands of clinical laboratories for accurate and reproducible results, supporting a wide range of assays and high-throughput testing.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Quantitative and Semi-Quantitative Determination of PPCPs and Their By-products in Wastewater Treatment Plants Samples Using UHPLC-Orbitrap MS and Data Mining Technologies
2015|Thermo Fisher Scientific|Posters
Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use Shih-Tse Jason Lai, Jia Wang, Brad Hart, Kristine Van Natta, Marta Kozak, Jorge Valdivia, Haibo Wang, and Erkan Diri Thermo Fisher…
Key words
hesi, hesiapci, apcipos, postifying, tifyingneg, negion, ionrming, rmingmobile, mobilephase, phaseloading, loadingeluting, elutingturboflow, turboflowquantifying, quantifyingprobe, probeconfirming
Usability Study of a New HPLC, a New Tandem MS and a New Data Processing Software
2015|Thermo Fisher Scientific|Posters
Poster N o te 6 43 75 Usability Study of a New HPLC, a New Tandem MS and a New Data Processing Software Jason Lai, Jia Wang, Brad Hart, Kristine Van Natta, Marta Kozak, Jorge Valdivia, Haibo Wang, Erkan Diri…
Key words
hesi, hesipos, posapci, apcineg, negprobe, probealprazolam, alprazolamreserpine, reserpineion, ionconfirming, confirmingquantifying, quantifyingcrashed, crashedpolarity, polarityeluting, elutingloading, loadingestradiol
LC-MS Medical Devices for Laboratory Developed Tests
2020|Thermo Fisher Scientific|Brochures and specifications
Be sure LC-MS Medical Devices for Laboratory Developed Tests For In Vitro Diagnostic Use Increase efficiency, productivity, and cost savings Performing laboratory developed tests by liquid chromatography-mass spectrometry Comprehensive and reliable LC-MS systems powered by a complete suite of software…
Key words
tsq, tsqldt, ldtquantis, quantislis, lisaltis, altisseries, seriesdiagnostic, diagnosticspectrometer, spectrometertracefinder, tracefinderlaboratory, laboratoryabundance, abundancemass, massldts, ldtsvitro, vitromedical
Thermo Scientific Prelude SPLC System
2016|Thermo Fisher Scientific|Brochures and specifications
Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex biological matrices presents significant challenges for clinical research and toxicology…
Key words
splc, splcprelude, preludeturboflow, turboflowclinical, clinicalsystem, systemproductivity, productivitymultiplexing, multiplexingresearch, researchutilization, utilizationincreases, increasesreproducible, reproducibleseparations, separationscyclosporin, cyclosporintacrolimus, tacrolimusthermo