Precise Quantitative Serum LC-MS/MS Profiling: The Impact of Sample Preparation and Sample Source on Biomarker Discovery Studies
Presentations | 2019 | Thermo Fisher ScientificInstrumentation
Serum and plasma proteome profiling has emerged as a critical approach for identifying disease biomarkers and understanding physiological changes. The high complexity and dynamic range of blood proteins challenge analytical methods, requiring optimized sample preparation and high-sensitivity mass spectrometry to detect low-abundance candidates. By reducing analytical variability and improving depth of coverage, reliable biomarkers can be discovered and validated for clinical and research applications.
This study investigates the influence of sample preparation protocols and source variability on quantitative serum LC-MS/MS profiling. It employs a multicenter triangular pipeline to assess analytical precision, biological variation across healthy donors, and differential protein regulation between sample sets. Advanced online low-flow and 2D LC-MS/MS strategies are evaluated to enhance proteome depth in biomarker discovery workflows.
Sample Preparation:
LC-MS/MS Analysis:
Used Instrumentation:
Analytical Precision:
Biological Variability:
Protein Regulation and Artifacts:
Deep Profiling Performance:
Pathway Analysis:
Standardized low-flow LC-MS workflows enable routine profiling of the top 200 abundant serum proteins with high sensitivity and reproducibility. The combination of automated online 2D separations and label-free quantification facilitates deep, high-throughput coverage suitable for targeted assay development. Critical evaluation of sample preparation protocols prevents false positives and supports reliable biomarker validation in QA/QC, clinical research, and pharmaceutical development.
Integration of data-independent acquisition (DIA) and targeted MS workflows promises further increases in throughput and quantification accuracy. Advances in microfluidics, automation, and machine learning-driven data analysis will enhance sample handling consistency and biomarker candidate prioritization. Expanding multi-omics integration will refine disease signatures and support precision medicine applications.
This study underscores the necessity of harmonized sample preparation and rigorous analytical pipelines in serum proteomics. While high-abundance protein profiling offers stability, its limited variability constrains novel biomarker discovery. Comprehensive online 2D low-flow LC-MS/MS provides a powerful platform for deep coverage, reducing artifacts and enabling the identification of disease-relevant proteins for future clinical translation.
LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap
IndustriesClinical Research
ManufacturerThermo Fisher Scientific
Summary
Significance of Topic
Serum and plasma proteome profiling has emerged as a critical approach for identifying disease biomarkers and understanding physiological changes. The high complexity and dynamic range of blood proteins challenge analytical methods, requiring optimized sample preparation and high-sensitivity mass spectrometry to detect low-abundance candidates. By reducing analytical variability and improving depth of coverage, reliable biomarkers can be discovered and validated for clinical and research applications.
Study Objectives and Overview
This study investigates the influence of sample preparation protocols and source variability on quantitative serum LC-MS/MS profiling. It employs a multicenter triangular pipeline to assess analytical precision, biological variation across healthy donors, and differential protein regulation between sample sets. Advanced online low-flow and 2D LC-MS/MS strategies are evaluated to enhance proteome depth in biomarker discovery workflows.
Methodology and Used Instrumentation
Sample Preparation:
- Three centers applied distinct clotting, temperature, and centrifugation protocols to collect serum from healthy volunteers.
- Fifteen individual samples were processed using standardized digestion and desalting workflows.
LC-MS/MS Analysis:
- Single-dimension low-flow separations (8–60 min gradients) and comprehensive online high-pH RP × low-pH RP 2D separations (2–8 fractions).
- Label-free quantification with data-dependent acquisition.
Used Instrumentation:
- Thermo Scientific UltiMate 3000 RSLCnano system.
- Exactive HF-X Hybrid Quadrupole-Orbitrap mass spectrometer.
- Orbitrap Exploris 480 mass spectrometer.
Main Results and Discussion
Analytical Precision:
- RSD < 15% for 88% of quantified proteins (248 of 265) across LC-MS replicates.
- 95% of proteins exhibited < 50% variation.
Biological Variability:
- Inter-individual protein variation exceeded analytical noise, yet > 80% of proteins varied by less than two-fold among healthy donors.
Protein Regulation and Artifacts:
- 94 proteins showed > 2-fold and 22 proteins > 4-fold abundance differences in healthy groups, highlighting sample handling artifacts rather than true biological differences.
- Classical blood proteins, including clotting factors and immunoglobulins, dominated differential profiles in one center due to preparation-induced release.
Deep Profiling Performance:
- Online 2D LC raised identification counts linearly with fractions: ~3,000 proteins in 8 fractions vs. ~800 in 2 fractions.
- 442 proteins and 3,536 unique peptides quantified across 15 individuals, identifying 237 proteins with ≥ 2-fold changes.
Pathway Analysis:
- Regulated proteins predominantly mapped to coagulation and innate immune pathways, reflecting preparation-induced variations.
Benefits and Practical Applications
Standardized low-flow LC-MS workflows enable routine profiling of the top 200 abundant serum proteins with high sensitivity and reproducibility. The combination of automated online 2D separations and label-free quantification facilitates deep, high-throughput coverage suitable for targeted assay development. Critical evaluation of sample preparation protocols prevents false positives and supports reliable biomarker validation in QA/QC, clinical research, and pharmaceutical development.
Future Trends and Potentials
Integration of data-independent acquisition (DIA) and targeted MS workflows promises further increases in throughput and quantification accuracy. Advances in microfluidics, automation, and machine learning-driven data analysis will enhance sample handling consistency and biomarker candidate prioritization. Expanding multi-omics integration will refine disease signatures and support precision medicine applications.
Conclusion
This study underscores the necessity of harmonized sample preparation and rigorous analytical pipelines in serum proteomics. While high-abundance protein profiling offers stability, its limited variability constrains novel biomarker discovery. Comprehensive online 2D low-flow LC-MS/MS provides a powerful platform for deep coverage, reducing artifacts and enabling the identification of disease-relevant proteins for future clinical translation.
Reference
- Boichenko A, Govorukhina N, Zheng R. Precise Quantitative Serum LC-MS/MS Profiling: The Impact of Sample Preparation and Sample Source on Biomarker Discovery Studies. J Proteome Res. 2014 Nov 7;13(11):4995-5007.
- Guzel C, et al. Comparison of Targeted Mass Spectrometry Techniques with an Immunoassay: A Case Study for HSP90α. Proteomics Clin Appl. 2018;12:1700107.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Plasma proteomics goes high throughput – timsTOF Pro with PASEF and 4D feature alignment to quantify 500 plasma proteins in 11.5 min
2019|Bruker|Applications
Plasma proteomics goes high throughput – timsTOF Pro with PASEF and 4D feature alignment to quantify 500 plasma proteins in 11.5 min The timsTOF Pro with PASEF and the Evosep One for biomarker discovery in large sample cohorts of human…
Key words
timstof, timstofproteins, proteinsevosep, evosepplasma, plasmaprotein, proteinquantified, quantifiedpro, proidentifications, identificationspasef, pasefproteomics, proteomicsbiomarker, biomarkerdiscovery, discoveryblood, bloodthroughput, throughputmobility
Unlocking the plasma proteome with Evotip Pure based, standardized and scalable workflows
2024|Evosep|Applications
Application Note Highlights Unlocking the plasma proteome with Evotip Pure based, standardized and scalable workflows Fully automated, end-to-end workflow for neat and deep plasma profiling Standardized and cost-efficient strategy to monitor disease at scale 1. Introduction Plasma stands out as…
Key words
neat, neatmagnet, magnetcancer, cancerplasma, plasmafda, fdamtpn, mtpnmarkers, markersrank, ranklung, lungevotips, evotipsbiomarker, biomarkerevotip, evotipprotein, proteindescending, descendingmedian
High-throughput plasma proteomics: A standardized and scalable workflow for quantitative protein profiling in large sample cohorts
2019|Thermo Fisher Scientific|Applications
APPLICATION NOTE No. 73194 High-throughput plasma proteomics: A standardized and scalable workflow for quantitative protein profiling in large sample cohorts Keywords Q Exactive, Orbitrap, protein biomarker, plasma workflow, serum workflow, Evosep, high throughput proteomics workflow Authors Jing Wang1; Sarah Trusiak1;…
Key words
cancer, cancerhealthy, healthylung, lungplasma, plasmascaled, scaledevosep, evosepabundance, abundanceeasypep, easypepworkflow, workflowprotein, proteingroups, groupspeptide, peptidealt, altpatient, patientthroughput
Orbitrap Exploris 240 mass spectrometer delivers significantly increased lab productivity and reproducibility of human plasma proteome profiling from large human cohort studies
2021|Thermo Fisher Scientific|Others
CASE STUDY 66002 Orbitrap Exploris 240 mass spectrometer delivers significantly increased lab productivity and reproducibility of human plasma proteome profiling from large human cohort studies “For large clinical cohort studies where hundreds of plasma samples are to be analyzed, a…
Key words
plasma, plasmauncg, uncggreensboro, greensborocarolina, carolinapmsc, pmscuhtppp, uhtppphundreds, hundredssamples, sampleshuman, humanprofiling, profilingcohort, cohortbiomedical, biomedicalreproducibility, reproducibilitylaboratory, laboratoryworkflow