Maximize productivity in proteome profiling

Technical notes | 2020 | Thermo Fisher ScientificInstrumentation
HPLC, LC/MS
Industries
Proteomics
Manufacturer
Thermo Fisher Scientific

Summary

Importance of the topic


Comprehensive proteome profiling is a cornerstone of modern biological research and quality control in pharmaceutical and clinical settings. Deep proteomic workflows rely on nanoLC-MS to achieve high sensitivity and separation performance. However, traditional single-column nanoLC methods suffer from low mass spectrometer utilization due to sequential sample loading, gradient elution, washing, and equilibration steps. Increasing productivity by reducing idle instrument time is essential for high-throughput applications and cost efficiency.

Study objectives and overview


This study aimed to develop and validate an easy-to-use tandem nanoLC-MS platform capable of near-100 percent MS utilization. By combining an intelligent tandem nanoLC fluidic setup with a novel double-barrel ESI source, the goal was to enable continuous sample analysis in both direct injection and trap-and-elute modes. The approach was demonstrated using 200 nanogram HeLa protein digest samples analyzed with 90-minute gradients.

Methodology


Sample preparation involved reconstituting a commercial HeLa protein digest to 200 ng/µL in 0.1 percent formic acid. Two operational modes were implemented: direct injection and trap-and-elute. The tandem nanoLC configuration used offset gradients on two parallel columns to maintain a continuous analyte stream to the mass spectrometer. Intelligent LC scripts coordinated valve switching and high-voltage application to ensure that the active column in the double-barrel source always received electrospray voltage. Standardized template methods were created for gradient lengths ranging from 24 to 120 minutes. Data-dependent acquisition on a Q Exactive HF-X mass spectrometer recorded MS1 scans at 60 000 resolution and MS2 scans at 15 000 resolution.

Used instrumentation


  • Thermo Scientific UltiMate 3000 RSLCnano modules: NCS-3500RS, NCP-3200RS, WPS-3000TPL RS autosampler
  • Sonation double-barrel column oven and NanoSpray Flex ion source conversion kit
  • Thermo Scientific Q Exactive HF-X mass spectrometer
  • Self-packed 75 µm × 40 cm C18 columns with pulled emitters
  • Thermo Scientific nanoViper fingertight capillaries and fittings

Key results and discussion


The optimized tandem nanoLC-MS setup consistently identified over 73 000 unique peptides and more than 6 100 protein groups per run. MS utilization increased from approximately 51 percent with a conventional single-column method to 98 percent with the tandem configuration, boosting throughput from 8 to 14 samples per day. Retention time reproducibility was excellent, with 99 percent of peptides exhibiting less than one minute variation between columns and runs. Protein quantification showed over 93 percent of quantified proteins varied by less than 25 percent across replicate analyses.

Benefits and practical applications


  • Near-100 percent mass spectrometer utilization reduces idle time and increases sample throughput
  • Automated alignment of columns and electrospray voltage via intelligent LC scripting simplifies sequence setup
  • Elimination of post-column fittings minimizes dispersion and peak broadening
  • One pump controlling both columns enhances retention time consistency
  • Compatibility with direct injection and trap-and-elute workflows supports diverse proteomic applications

Future trends and potential applications


Further developments may include integration with other high-resolution mass spectrometers, expanded automation for valve and voltage control, and coupling with machine-learning algorithms for adaptive method optimization. The tandem nanoLC approach can be extended to phosphoproteomics, metabolomics, and high-throughput clinical assays. Customizable template methods offer opportunities for tailoring workflows to specialized sample types and gradient designs.

Conclusion


The intelligent tandem nanoLC-MS platform with a double-barrel ESI source represents a significant advance in proteome profiling. By synchronizing parallel columns and automating fluidic and voltage controls, the system achieves near-continuous MS acquisition and robust reproducibility. This workflow maximizes productivity for deep-dive proteomic studies, offering practical advantages for research and industrial laboratories.

References


  1. Pynn C, Boychenko A, Decrop W, Baynham M, Jehle P, Ruehl M. Tandem nanoLC-MS maximum MS utilization for deep-dive proteomic analysis. Thermo Scientific Technical Note. TN72899; 2020.
  2. Sonation GmbH. Column Oven PRSO-V2 User Manual. Version 1.0. 2018.
  3. R Core Team. R A language and environment for statistical computing. Vienna, Austria: R Foundation for Statistical Computing; 2019.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Novel tandem nano and capillary flow LC-MS-based approach for facile 24/7 proteome profiling with near 100% MS utilization
Low-Flow Tandem LC-MS Novel tandem nano and capillary flow LC-MS-based approach for facile 24/7 proteome profiling with near 100% MS utilization Runsheng Zheng1, Martin Rendl1, Ece Aydin1, Christopher Pynn1, Alec C Valenta2, Andrius Žilionis3, Robert Van Ling4, Georg Völkle5, Wim…
Key words
tandem, tandemdirect, directworkflow, workflowseparation, separationbarrel, barrelinjection, injectionpump, pumpcolumn, columnneo, neodouble, doublevanquish, vanquishloading, loadingcolumns, columnsnano, nanohram
Double Barrel ESI Source and Novel Tandem NanoLC-MS Setup Enables 24/7 Proteome Profiling with Close to 100% MS Utilization
Double Barrel ESI Source and Novel Tandem NanoLC-MS Setup Enables 24/7 Proteome Profiling with Close to 100% MS Utilization Runsheng Zheng1, Thomas Lanzinner2, Georg Völkle3, Christopher Pynn1, Jan Linnemann2, John Modrow2, Wim Decrop1, Andreas Tebbe2, Peter Jehle1, Mauro De Pra1,…
Key words
nanolc, nanolcwashing, washingtandem, tandemgradient, gradientloading, loadingplatform, platformdeep, deepnano, nanohram, hramequilibration, equilibrationprofiling, profilingcolumns, columnstwosteps, twostepsproteome, proteomecolumn
Maximizing sample throughput and sensitivity in nano- and capillary-LC-MS
Technical note | 003335 Omics Maximizing sample throughput and sensitivity in nano- and capillary-LC-MS Harnessing a tandem direct injection workflow and a dual spray ion source Authors Goal Runsheng Zheng , Martin Rendl , Alec C. Valenta2, Christopher Pynn1, Till…
Key words
tandem, tandempump, pumpnano, nanoquantified, quantifiedworkflow, workflowwash, washfossiliontech, fossiliontechprotein, proteinthroughput, throughputsonation, sonationlotus, lotusvanquish, vanquishcolumn, columnmicrotight, microtightemitter
Enhancing sample throughput for deep dive proteomics with Tandem LC
High-throughput LC-MS Enhancing sample throughput for deep dive proteomics with Tandem LC Runsheng Zheng1, Martin Rendl1, Alec Valenta2, Tabiwang Arrey3, Christopher Pynn1, Yuan Lin4, Maksim Daniliuk5, Ece Aydin1 Robert van Ling6, Wim Decrop1, Felix Josef7, Til Reinhardt3, Nagarjuna Nagaraj7, Andreas…
Key words
tdi, tdiworkflow, workflowthroughput, throughputtandem, tandemfossiliontech, fossiliontechvanquish, vanquishmicrotight, microtightdive, divedirect, directdda, ddautilization, utilizationchimerys, chimerysnano, nanonode, nodetmt
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike