Grant application resource: Thermo Scientific Orbitrap ID-X Tribrid mass spectrometer for metabolomics, lipidomics and structural elucidation
Technical notes | 2018 | Thermo Fisher ScientificInstrumentation
The analysis of small molecules in complex biological and environmental samples requires mass spectrometers capable of ultra-high resolution, sub-ppm mass accuracy and versatile fragmentation. Untargeted metabolomics and lipidomics workflows generate thousands of features, many of which are low-abundance or isomeric species. Differentiating true biological analytes from background ions and confidently annotating structures demands advanced hardware and intelligent acquisition strategies.
This white paper outlines the key advantages of the Thermo Scientific Orbitrap ID-X Tribrid mass spectrometer compared to earlier Orbitrap hybrid platforms. It aims to justify an upgrade by demonstrating improved untargeted metabolite and lipid annotation, enhanced structural elucidation via multiple MSn techniques, and automated workflows to maximize the yield of meaningful MS2 and MSn spectra.
The Orbitrap ID-X Tribrid integrates a quadrupole filter, high-field Orbitrap and linear ion trap to perform full-scan HRAM MS and parallel MSn experiments. Standardized method templates support untargeted metabolomics, lipidomics, spectral library building and targeted neutral-loss or product-ion triggers. AcquireX automates blank subtraction and iterative injections with dynamic exclusion/inclusion lists to prioritize biologically relevant ions and virtually eliminate background MS2 spectra.
• Mass measurement accuracy consistently <1 ppm (internal calibration) across LC peaks, demonstrated for endogenous creatine and a 24-compound mix over 72 h.
• Ultra-high resolution (500 000) enables isotope fine‐structure separation (e.g., 15N vs. 33S) for confident elemental composition assignment.
• AcquireX reduces background MS2 from 76 % to <1 %, doubles MS2 on relevant precursors and more than doubles high-quality library matches in mzCloud over three injections.
• MSn workflows differentiate isomeric flavonoids (kaempferol-3-O-rutinoside vs. luteolin-7-rutinoside) by distinct MS3 spectral fingerprints following neutral-loss MS2.
• Targeted MS3 via neutral-loss filters resolves isomeric triglycerides (e.g., TG 14:0-16:0-18:1 vs. TG 16:0-16:1-16:0) by fragmenting diagnostic fatty-acid losses in MS2 and collecting MS3 spectra.
Advances will include real-time AI-driven acquisition decisions, expanded spectral libraries with community-wide sharing, integration with microfluidic and ion-mobility platforms, and clinical translation of high-coverage metabolomics in precision medicine. Further automation and higher throughput will extend untargeted workflows to large cohort studies.
The Orbitrap ID-X Tribrid mass spectrometer delivers state-of-the-art performance for untargeted metabolomics and lipidomics. Its combination of ultra-high resolution, precise mass measurement, parallel MSn capabilities and intelligent AcquireX workflows provides unparalleled confidence in compound annotation and structural elucidation, addressing major challenges in small-molecule analysis.
LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap
IndustriesMetabolomics, Lipidomics
ManufacturerThermo Fisher Scientific
Summary
Significance of the Topic
The analysis of small molecules in complex biological and environmental samples requires mass spectrometers capable of ultra-high resolution, sub-ppm mass accuracy and versatile fragmentation. Untargeted metabolomics and lipidomics workflows generate thousands of features, many of which are low-abundance or isomeric species. Differentiating true biological analytes from background ions and confidently annotating structures demands advanced hardware and intelligent acquisition strategies.
Objectives and Study Overview
This white paper outlines the key advantages of the Thermo Scientific Orbitrap ID-X Tribrid mass spectrometer compared to earlier Orbitrap hybrid platforms. It aims to justify an upgrade by demonstrating improved untargeted metabolite and lipid annotation, enhanced structural elucidation via multiple MSn techniques, and automated workflows to maximize the yield of meaningful MS2 and MSn spectra.
Instrumentation Used
- OptaMax NG HESI/APCI ion source with optional EASY-IC internal calibration
- Active Beam Guide and stacked-ring S-Lens ion optics
- Quadrupole mass filter (m/z 50–2000) with 0.4 amu isolation
- Ion-Routing Multipole for parallel HCD fragmentation at any MSn stage
- Dual-pressure linear ion trap (CID MSn up to MS10)
- High-field Orbitrap analyzer (resolution up to 500 000 FWHM at m/z 200)
- Scan rates: Orbitrap MS up to 30 Hz, ion trap MS up to 40 Hz
- AcquireX intelligent data-dependent acquisition with iterative exclusion/inclusion
Methodology and Instrumentation
The Orbitrap ID-X Tribrid integrates a quadrupole filter, high-field Orbitrap and linear ion trap to perform full-scan HRAM MS and parallel MSn experiments. Standardized method templates support untargeted metabolomics, lipidomics, spectral library building and targeted neutral-loss or product-ion triggers. AcquireX automates blank subtraction and iterative injections with dynamic exclusion/inclusion lists to prioritize biologically relevant ions and virtually eliminate background MS2 spectra.
Main Results and Discussion
• Mass measurement accuracy consistently <1 ppm (internal calibration) across LC peaks, demonstrated for endogenous creatine and a 24-compound mix over 72 h.
• Ultra-high resolution (500 000) enables isotope fine‐structure separation (e.g., 15N vs. 33S) for confident elemental composition assignment.
• AcquireX reduces background MS2 from 76 % to <1 %, doubles MS2 on relevant precursors and more than doubles high-quality library matches in mzCloud over three injections.
• MSn workflows differentiate isomeric flavonoids (kaempferol-3-O-rutinoside vs. luteolin-7-rutinoside) by distinct MS3 spectral fingerprints following neutral-loss MS2.
• Targeted MS3 via neutral-loss filters resolves isomeric triglycerides (e.g., TG 14:0-16:0-18:1 vs. TG 16:0-16:1-16:0) by fragmenting diagnostic fatty-acid losses in MS2 and collecting MS3 spectra.
Benefits and Practical Applications
- Enhanced metabolome and lipidome coverage with high confidence annotations
- Automated, high-throughput acquisition reduces false positives and data processing burden
- Comprehensive structural elucidation via combined HCD and CID MSn without method reconfiguration
- Robust quantitation supported by stable mass accuracy and dynamic range >5000 in single scans
- Pre-defined templates accelerate method development for routine QA/QC and research applications
Future Trends and Potential Applications
Advances will include real-time AI-driven acquisition decisions, expanded spectral libraries with community-wide sharing, integration with microfluidic and ion-mobility platforms, and clinical translation of high-coverage metabolomics in precision medicine. Further automation and higher throughput will extend untargeted workflows to large cohort studies.
Conclusion
The Orbitrap ID-X Tribrid mass spectrometer delivers state-of-the-art performance for untargeted metabolomics and lipidomics. Its combination of ultra-high resolution, precise mass measurement, parallel MSn capabilities and intelligent AcquireX workflows provides unparalleled confidence in compound annotation and structural elucidation, addressing major challenges in small-molecule analysis.
References
- Gertsman IG, Barshop BA. The promises and pitfalls of untargeted metabolomics. J Inherit Metab Dis. 2018;41:355–366.
- Patti GJ, Dunn WB, Creek DJ, Sumner LW. The journey from features to compound identification in metabolomics. The Scientist. 2018;eBook #65354.
- Eliuk S, Makarov A. Evolution of Orbitrap mass spectrometry instrumentation. Annu Rev Anal Chem. 2015;8:61–80.
- Peake DA. High-resolution compound identification in metabolomics: a review of current practices. Rev Anal Chem. 2018;65356.
- Mahieu NG, Patti GJ. Systems-level annotation of a metabolomics data set reduces 25 000 features to fewer than 1000 unique metabolites. Anal Chem. 2017;89(17):10397–10406.
- Barbier-Saint Hilaire P, Hohenester UM, Colsch B, et al. Evaluation of the high-field Orbitrap Fusion for compound annotation in metabolomics. Anal Chem. 2018;90(5):3030–3035.
- Ntai I, Mohtashemi I, Berryhill J, et al. Improved metabolome coverage and increased confidence in unknown identification through novel automated acquisition strategies. Poster #65286. 2017.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Thermo Scientific Orbitrap ID-X Tribrid mass spectrometer
2018|Thermo Fisher Scientific|Brochures and specifications
Orbitrap ID-X Tribrid mass spectrometer Transforming small molecule identification and characterization A leap ahead for small molecule analyses Acquisition and interpretation of mass spectra to characterize and identify small-molecule unknowns is a formidable task. Sample complexities, background interferences, compound structural…
Key words
lib, libtribrid, tribridabundance, abundancekynurenine, kynureninedda, ddamass, massstructure, structureanthranilate, anthranilateacquirex, acquirexformylkynurenine, formylkynureninealanine, alanineinclusion, inclusionorbitrap, orbitraprelative, relativerelativeabundance
General workflow for untargeted plasma lipidomics on Orbitrap mass spectrometers
2023|Thermo Fisher Scientific|Technical notes
Technical note | 002661 Metabolomics General workflow for untargeted plasma lipidomics on Orbitrap mass spectrometers Authors Introduction to lipidomics Rahul Deshpande, Ciara Myer, Susan Bird Lipids play a key role in cell, tissue, and organ physiology as key components of…
Key words
orbitrap, orbitrapmass, masstribrid, tribridspectrometer, spectrometerlipidomics, lipidomicsfragmentation, fragmentationlipid, lipidannotation, annotationexploris, explorisacquirex, acquirexnegative, negativeworkflow, workflowabundance, abundanceexclusion, exclusionconfident
Harness the power of metabolomics
2021|Thermo Fisher Scientific|Brochures and specifications
Go beyond Harness the power of metabolomics The total package for metabolomics By collaborating with the scientific community, we’ve developed pioneering metabolomics solutions that combine Thermo Scientific™ Orbitrap™ LC-MS instruments with powerful data analysis software and novel spectral libraries. With…
Key words
annotation, annotationmass, massmetabolomics, metabolomicsdiet, dietfat, fatuhram, uhrammzcloud, mzcloudthermo, thermofragmentation, fragmentationscientific, scientificspectral, spectraldiscoverer, discoverersoftware, softwarelibrary, librarytargeted
Grant application resource for Orbitrap IQ-X Tribrid mass spectrometer
2021|Thermo Fisher Scientific|Technical notes
Mass spectrometry WHITE PAPER Grant application resource for Orbitrap IQ-X Tribrid mass spectrometer Reveal complex chemical structures with ultimate confidence, ease, and experimental versatility Keywords Metabolite identification, untargeted metabolomics, lipidomics, lipids, oligonucleotides, natural products, compound annotation, unknown analysis, structure elucidation,…
Key words
tribrid, tribridorbitrap, orbitrapmolecule, moleculesmall, smallacquirex, acquirexmass, massexclusion, exclusionion, ionreal, realuvpd, uvpdspectral, spectralsoftware, softwarelibrary, libraryinclusion, inclusionscientific