High Performance Packed Column for HPLC - Scepter Diol-HILIC Series
Manuals | | ShimadzuInstrumentation
Hydrophilic interaction liquid chromatography (HILIC) is widely used for separating polar compounds in pharmaceuticals, bioanalysis and food testing. Shim-pack Scepter Diol-HILIC columns offer high efficiency and reproducibility, making them valuable for laboratories seeking robust, metal-free columns compatible with UHPLC pressures.
This manual provides practical guidance for installing, operating and maintaining Shim-pack Scepter Diol-HILIC columns. It aims to help users protect column integrity, optimize chromatographic performance and extend column lifetime.
Ultrahigh-performance columns packed with 1.9 µm, 3 µm or 5 µm dihydroxypropyl bonded silica are designed for use with HPLC/UHPLC systems. Recommended tubing:
Quality control testing confirms consistent column performance. Proper installation with male nuts, ferrules or Nexlock fittings avoids dead volume and peak broadening. Metal-free connections reduce metal contamination risks. UHPLC operation requires minimized extra-column volume: tubing length under 5 cm and detector flow cells of low volume. Data rates ≥10 points/peak and response times <0.1 s preserve sharp peaks.
Ongoing improvements may include novel stationary phases with enhanced selectivity, deeper integration with mass spectrometry via metal-free interfaces, and micro-UHPLC formats for limited sample volumes. Automated column washing and real-time monitoring of backpressure trends will further extend column lifetime.
Shim-pack Scepter Diol-HILIC columns deliver stable, high-performance separations in HILIC mode when installed and maintained correctly. Observing pressure limits, proper mobile phase preparation and careful system setup ensures reliable results and prolonged column life.
Shimadzu Corporation. Shim-pack Scepter Diol-HILIC Series Instruction Manual. ERAD-0001-9045.
Consumables, LC columns
IndustriesManufacturerShimadzu
Summary
Importance of the topic
Hydrophilic interaction liquid chromatography (HILIC) is widely used for separating polar compounds in pharmaceuticals, bioanalysis and food testing. Shim-pack Scepter Diol-HILIC columns offer high efficiency and reproducibility, making them valuable for laboratories seeking robust, metal-free columns compatible with UHPLC pressures.
Objectives and Study Overview
This manual provides practical guidance for installing, operating and maintaining Shim-pack Scepter Diol-HILIC columns. It aims to help users protect column integrity, optimize chromatographic performance and extend column lifetime.
Methodology and Instrumentation
Ultrahigh-performance columns packed with 1.9 µm, 3 µm or 5 µm dihydroxypropyl bonded silica are designed for use with HPLC/UHPLC systems. Recommended tubing:
- PEEK or stainless steel (UHPLC) with 0.1–0.3 mm ID
- Outer diameter of 1.6 mm
Key Results and Discussion
Quality control testing confirms consistent column performance. Proper installation with male nuts, ferrules or Nexlock fittings avoids dead volume and peak broadening. Metal-free connections reduce metal contamination risks. UHPLC operation requires minimized extra-column volume: tubing length under 5 cm and detector flow cells of low volume. Data rates ≥10 points/peak and response times <0.1 s preserve sharp peaks.
Benefits and Practical Applications
- High resolution and reproducibility for polar analytes
- Compatibility with a wide pH range and buffer strengths
- Reduced sample adsorption due to Diol chemistry
- Metal-free flow path minimizes unwanted interactions
Future Trends and Applications
Ongoing improvements may include novel stationary phases with enhanced selectivity, deeper integration with mass spectrometry via metal-free interfaces, and micro-UHPLC formats for limited sample volumes. Automated column washing and real-time monitoring of backpressure trends will further extend column lifetime.
Conclusion
Shim-pack Scepter Diol-HILIC columns deliver stable, high-performance separations in HILIC mode when installed and maintained correctly. Observing pressure limits, proper mobile phase preparation and careful system setup ensures reliable results and prolonged column life.
References
Shimadzu Corporation. Shim-pack Scepter Diol-HILIC Series Instruction Manual. ERAD-0001-9045.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Shim-pack - Scepter Diol-HILIC Series - INSTRUCTION MANUAL
|Shimadzu|Manuals
ASPM-0033A High Performance Packed Column for HPLC Shim-pack Scepter Diol-HILIC Series INSTRUCTION MANUAL ■ Introduction The column should be connected with male nuts. Ensure that the To maintain and maximize peak performance of Shim-pack Scepter fittings are connected properly to…
Key words
scepter, sceptercolumn, columnshim, shimdiol, diolpack, packhilic, hilicpressure, pressuresolvent, solventprecautions, precautionsmobile, mobileinstalling, installingoperating, operatingprecipitation, precipitationshould, shouldfittings
High Performance Packed Column for HPLC - Scepter Series
|Shimadzu|Manuals
ERAD_0001-9043A High Performance Packed Column for HPLC Shim-pack Scepter Series INSTRUCTION MANUAL ■ Introduction The column should be connected with male nuts. Ensure that the To maintain and maximize peak performance of Shim-pack Scepter series columns, and to ensure the…
Key words
scepter, sceptershim, shimpack, packcolumn, columnprecautions, precautionspfpp, pfppphenyl, phenylpressure, pressureguard, guardeluent, eluentperformance, performancecolumns, columnsinstalling, installingvalve, valvepreparative
High Performance Packed Column for HPLC - Bio-Diol - Shim-pack - INSTRUCTION MANUAL
|Shimadzu|Manuals
ASPM-0035 High Performance Packed Column for HPLC Shim-pack Bio-Diol INSTRUCTION MANUAL ■ Introduction Ensure that the fittings are connected properly to avoid creating To maintain and maximize peak performance of Shim-pack Bio- dead volume between the tubing and the column…
Key words
column, columnshim, shimdiol, diolpack, packbio, biopressure, pressureprecautions, precautionslimit, limitname, namefittings, fittingshydrophobic, hydrophobicperformance, performancesize, sizenexlock, nexlockguard
High Performance Packed Column for HPLC - Bio-Diol
|Shimadzu|Manuals
ERAD-0001-9049 High Performance Packed Column for HPLC Shim-pack Bio-Diol INSTRUCTION MANUAL ■ Introduction Ensure that the fittings are connected properly to avoid creating To maintain and maximize peak performance of Shim-pack Bio- dead volume between the tubing and the column…
Key words
shim, shimcolumn, columndiol, diolpack, packbio, biopressure, pressureprecautions, precautionslimit, limitname, namefittings, fittingshydrophobic, hydrophobicperformance, performancesize, sizenexlock, nexlockguard