Summary

Importance of the topic


High performance liquid chromatography (HPLC) relies on well-characterized columns to deliver sharp, reproducible peaks and long operational lifetimes. Shim-pack Scepter series packed columns exemplify modern stationary phases offering rapid separations across a range of chemistries, critical for quality control, research, and pharmaceutical analysis.

Objectives and overview


This instruction manual outlines proper installation, operation, maintenance, and storage procedures for Shim-pack Scepter columns. It aims to maximize column performance, prevent damage, and ensure consistent chromatographic results.

Methodology and instrumentation


  • Columns: Shim-pack Scepter series with C18, HD-C18, C8, phenyl, PFPP, and C4-300 chemistries, packed at 1.9, 3, or 5 μm particle sizes.
  • Instrumentation: Standard HPLC or UHPLC systems capable of 45–100 MPa pressures, PEEK or stainless steel tubing (0.1–0.3 mm ID), compatible fittings (PEEK nuts, ferrules, Nexlock).
  • Connections: Use male nuts and recommended ferrules; avoid dead volume by proper tightening and minimal tubing length.

Main results and discussion


  • Pressure limits depend on particle size and column dimensions; 1.9 μm columns tolerate up to 100 MPa, larger particles up to 45 MPa.
  • Dead volume and improper connections lead to peak broadening and tailing; recommended flow rates vary with tubing ID and particle size.
  • Solvent compatibility: Gradual solvent transitions and proper pH buffers enhance column stability; THF and high-organic washes clear strongly retained species.
  • Clogging prevention: Pre-filter mobile phases and samples (0.2 μm), install guard columns or ghost traps, degas solvents to avoid bubbles.
  • Temperature and pH ranges: Most chemistries operate from pH 1–12 and up to 50–70 °C, depending on stationary phase.

Benefits and practical applications


Shim-pack Scepter columns deliver robust, high-resolution separations with broad chemistry coverage. Their metal-free connections and wide pressure ratings support routine and ultra-high performance applications in environmental, pharmaceutical, and biochemical analyses.

Future trends and potential uses


Anticipated developments include sub-2 μm stationary phases tailored for ultra-high throughput, enhanced selectivities via novel functional groups, and integration with mass spectrometry. Advances in column hardware may allow higher pressures and reduced extra-column volumes.

Conclusion


Proper handling and maintenance of Shim-pack Scepter columns ensure optimal chromatographic performance and extended lifetime. Adherence to pressure, solvent, and temperature guidelines is essential for reliable analyses.

References


  • No references provided in the original document.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
High Performance Packed Column for HPLC - Scepter Diol-HILIC Series
ERAD-0001-9045 High Performance Packed Column for HPLC Shim-pack Scepter Diol-HILIC Series INSTRUCTION MANUAL ■ Introduction The column should be connected with male nuts. Ensure that the To maintain and maximize peak performance of Shim-pack Scepter fittings are connected properly to…
Key words
scepter, sceptercolumn, columnshim, shimdiol, diolpack, packhilic, hilicpressure, pressuresolvent, solventmobile, mobileprecautions, precautionsinstalling, installingoperating, operatingprecipitation, precipitationshould, shouldfittings
Shim-pack - Scepter Diol-HILIC Series - INSTRUCTION MANUAL
ASPM-0033A High Performance Packed Column for HPLC Shim-pack Scepter Diol-HILIC Series INSTRUCTION MANUAL ■ Introduction The column should be connected with male nuts. Ensure that the To maintain and maximize peak performance of Shim-pack Scepter fittings are connected properly to…
Key words
scepter, sceptercolumn, columnshim, shimdiol, diolpack, packhilic, hilicpressure, pressuresolvent, solventmobile, mobileprecautions, precautionsinstalling, installingoperating, operatingprecipitation, precipitationshould, shouldfittings
Shim-pack GIST/GISS Series INSTRUCTION MANUAL
ERAD-0001-9007 High Performance Packed Column for HPLC Shim-pack GIST/GISS Series INSTRUCTION MANUAL  Introduction  Column Installation To maintain and maximize peak performance of Shim-pack GIST/GISS series columns, and to ensure the long life and stability of columns, please read…
Key words
gist, gistshim, shimpack, packgiss, gisscolumn, columnphenyl, phenylcolumns, columnsoperating, operatingseries, seriesgroups, groupspressure, pressuresolvent, solventperformance, performanceeluent, eluenthexyl
High Performance Packed Column for HPLC - Bio-IEX Series - Shim-pack - INSTRUCTION MANUAL
ASPM-0037 High Performance Packed Column for HPLC Shim-pack Bio-IEX Series INSTRUCTION MANUAL ■ Introduction ■ Column performance To maintain and maximize peak performance of Shim-pack Bio- The Shim-pack Bio-IEX series have stable quality products for IEX series columns, and to…
Key words
iex, iexbio, bioshim, shimcolumn, columnpack, packitem, itemsoluble, solubleshortest, shortestmaterial, materialmpa, mpatubing, tubingperformance, performanceshipping, shippingcounter, counterprecautions
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike