OpenLAB ECM: Site Preparation Checklist - ECM 3.4.1 and 3.4.1 SP1
Manuals | 2014 | Agilent TechnologiesInstrumentation
Proper preparation of the installation site for OpenLAB ECM is essential to guarantee reliable long-term operation of laboratory informatics systems. By defining clear hardware, software and network prerequisites, organizations can minimize downtime, avoid configuration issues and ensure smooth integration of critical data management components.
The primary goal of this checklist is to guide customers through the steps necessary to meet or exceed Agilent’s minimum requirements for installing OpenLAB ECM 3.4.1 and SP1. It clarifies customer responsibilities, outlines recommended infrastructure configurations and highlights key validation criteria prior to on-site implementation.
This site preparation procedure is organized by system role. Detailed specifications are provided for:
The checklist consolidates best practices to align server roles, network topology and security policies with Agilent’s support matrix. Emphasis is placed on isolating database servers, validating domain and IP configurations, installing required .NET and client tools in advance, and verifying performance through ping and traceroute tests. Virtual machine support is confirmed for each component provided vendor recommendations are followed.
Adhering to this site preparation guide enables laboratories to:
Looking ahead, widespread adoption of cloud-hosted database platforms, containerized deployment of web and application tiers, and automated infrastructure provisioning via IaC (Infrastructure as Code) are set to simplify site preparation. Integration with DevOps pipelines and enhanced monitoring tools will further reduce manual configuration and accelerate validation cycles.
This site preparation checklist serves as a comprehensive roadmap for installing OpenLAB ECM 3.4.1 and SP1. By following the outlined responsibilities, hardware/software requirements and network validations, organizations can ensure a robust, scalable and maintainable informatics environment.
Software
IndustriesManufacturerAgilent Technologies
Summary
Significance of the Topic
Proper preparation of the installation site for OpenLAB ECM is essential to guarantee reliable long-term operation of laboratory informatics systems. By defining clear hardware, software and network prerequisites, organizations can minimize downtime, avoid configuration issues and ensure smooth integration of critical data management components.
Objectives and Overview of the Study
The primary goal of this checklist is to guide customers through the steps necessary to meet or exceed Agilent’s minimum requirements for installing OpenLAB ECM 3.4.1 and SP1. It clarifies customer responsibilities, outlines recommended infrastructure configurations and highlights key validation criteria prior to on-site implementation.
Methodology and Instrumentation
This site preparation procedure is organized by system role. Detailed specifications are provided for:
- SQL Database Server: Dedicated hardware or supported virtual machine, SQL Server 2008 Standard/Enterprise R2, alphanumeric server naming, English-US collation, NTFS volumes, 2 GHz+ processor, 2–4 GB RAM and 100 GB+ storage.
- Oracle Database Server: Oracle 11g R2 Standard/Enterprise, UTF8/AL32UTF8 character set, separation of 32-bit client and 64-bit database, supported virtualization and recommended DBA tuning.
- ECM Web, File Transfer and Application Servers: Windows Server 2008 R2 (64-bit), .NET Framework 1.1–3.5 SP1, SQL Client tools, firewall port settings (HTTP, HTTPS, SMTP, database ports), role-based sizing (CPU, RAM, disk) and supported storage backends (Tivoli, EMC Centera).
- ECM Clients and Scheduler: Windows XP/7/2008 R2, Internet Explorer 8–10, .NET 2.0+, Office or Acrobat plug-in dependencies, 2 GHz+ CPU, 1–2 GB RAM, 40–200 GB local disk for scheduler cache, domain service account setup with static IP and appropriate network shares.
Main Findings and Discussion
The checklist consolidates best practices to align server roles, network topology and security policies with Agilent’s support matrix. Emphasis is placed on isolating database servers, validating domain and IP configurations, installing required .NET and client tools in advance, and verifying performance through ping and traceroute tests. Virtual machine support is confirmed for each component provided vendor recommendations are followed.
Benefits and Practical Applications
Adhering to this site preparation guide enables laboratories to:
- Accelerate deployment by avoiding last-minute hardware or software gaps.
- Improve system stability through correct partitioning, permissions and service account management.
- Facilitate compliance by standardizing locale, collation and security settings.
- Streamline upgrades and support by documenting network and server prerequisites.
Future Trends and Potential Applications
Looking ahead, widespread adoption of cloud-hosted database platforms, containerized deployment of web and application tiers, and automated infrastructure provisioning via IaC (Infrastructure as Code) are set to simplify site preparation. Integration with DevOps pipelines and enhanced monitoring tools will further reduce manual configuration and accelerate validation cycles.
Conclusion
This site preparation checklist serves as a comprehensive roadmap for installing OpenLAB ECM 3.4.1 and SP1. By following the outlined responsibilities, hardware/software requirements and network validations, organizations can ensure a robust, scalable and maintainable informatics environment.
References
- Agilent Technologies. OpenLAB ECM 3.4.1 and 3.4.1 SP1 Site Preparation Checklist. Issued 09-May-2014, Revision 3.4.1.2.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent OpenLAB ECM: Site Preparation Checklist
2015|Agilent Technologies|Manuals
OpenLAB ECM 35 – Site Preparation Checklist OpenLAB ECM: Site Preparation Checklist ECM 3.5 o Including ECM Scheduler and Client plug-ins Issued: 30-Nov-2015 Revision: 3.5 Copyright 1 2015 Page 1 of 9 Agilent Technologies OpenLAB ECM 35 –…
Key words
copyright, copyrightchecklist, checklistsite, sitedvd, dvdrom, rommemory, memoryprocessor, processorecm, ecmverify, verifytechnologies, technologiesdisks, disksspecification, specificationpreparation, preparationoracle, oracleagilent
Agilent OpenLAB ECM 3.5 - Site Preparation Checklist
2015|Agilent Technologies|Manuals
OpenLAB ECM 35 – Site Preparation Checklist OpenLAB ECM: Site Preparation Checklist ECM 3.5 o Including ECM Scheduler and Client plug-ins Issued: 30-Nov-2015 Revision: 3.5 Copyright 1 2015 Page 1 of 9 Agilent Technologies OpenLAB ECM 35 –…
Key words
copyright, copyrightchecklist, checklistsite, sitedvd, dvdrom, rommemory, memoryprocessor, processorecm, ecmverify, verifytechnologies, technologiesdisks, disksspecification, specificationpreparation, preparationagilent, agilentoracle
Agilent OpenLab ECM Revision 3.6 - Site Preparation Checklist
2019|Agilent Technologies|Manuals
Agilent OpenLab ECM Revision 3.6 Site Preparation Checklist Thank you for purchasing an Agilent system. To get you started and to assure a successful and timely installation of your Agilent software, please refer to this specification or set of requirements.…
Key words
ecm, ecmdatabase, databaseserver, serversql, sqlservers, serversrecommended, recommendednetwork, networkchecklist, checklistspecification, specificationoracle, oraclesite, sitedomain, domaincores, coresaccount, accountmemory
Agilent OpenLab ECM XT Server/ OpenLab Server v2.6 Software - Site Preparation Checklist
2021|Agilent Technologies|Manuals
Agilent CrossLab Start Up Services Agilent OpenLab ECM XT Server/ OpenLab Server v2.6 Software Site Preparation Checklist Thank you for purchasing software from Agilent Technologies. CrossLab Start Up is focused on helping customers shorten the time it takes to start…
Key words
ecm, ecmopenlab, openlabserver, serverrequirements, requirementssoftware, softwaredatacenter, datacenteredition, editionclient, clientsite, sitehardware, hardwareclients, clientsagilent, agilentspecification, specificationsystem, systemcustomer