LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike
Author
Bioanalytic
Bioanalytic
Bioanalytic started its operations in 1998. The company was born from a passion for science and the need to provide innovative solutions in the laboratory equipment market, from a small business to a dynamically developing company with an established position.
Tags
Article
Poster
Health
LinkedIn Logo

How sure you can be of the results of quantification of psychoactive compounds in blood?

Th, 23.1.2025
| Original article from: Bioanalytic
In this work we show a HR-MS/MS method for a sensitive detection of 27 psychoactive compounds with high confidence in venous blood and blood collected on a volumetric absorptive microsampling (VAMS) probe.
<p><strong>Bioanalytic:</strong> How sure you can be of the results of quantification of psychoactive compounds in blood?</p>

Bioanalytic: How sure you can be of the results of quantification of psychoactive compounds in blood?

Anna Lenartowicz (1); Julia Mironenka (1); Adrian Soboń (1,2); Rafał Szewczyk (1,2); Katarzyna Krupczyńska-Stopa (1,2); Maciej Stopa (1,2); Andrzej Kwaśnica (3)
1 – LabExperts sp. z o. o., Gdańsk, Poland; 2 – Bioanalytic sp. z o. o., Gdańsk, Poland; 3 – Lab4Tox sp. z o. o., Wrocław, Poland

Introduction

Compound presence confirmation is one of the key aspects of targeted and quantitative analysis in forensics applications. High resolution tandem mass spectrometry (HR-MS/MS) may become a major tool for this kind of analysis because of its mass accuracy resulting in unparallel specificity, all combined with broad linearity and scanning speed achieved in the newest hardware on the market. In this work we show a modern HR-MS/MS method for a sensitive detection of 27 analytes with high confidence in venous blood and blood collected on a volumetric absorptive microsampling (VAMS) probe. Analytes include: Tramadol, Morphine, Fentanyl, Methadone, Codeine, Alprazolam, Diazepam, Flunitrazepam, Lorazepam, Oxazepam, Zolpiclone, Clonazepam, Nordiazepam, Zolpidem, Hydroxyzine, Amphetamine, Methamphetamine, MDA, MDMA, MDEA, THC, Cocaine, 6-acetylmorphine, 7-aminoflunitrazepam, 7-aminoclonazepam, Benzoylecgonine, THC-COOH.

Materials and Methods

Briefly, sample preparation included: spiking of internal standards, protein precipitation and extraction using acetonitrile:methanol (1:1) with 0.1% formic acid, evaporation under nitrogen stream and reconstitution in LC mobile phase. Compounds were analyzed using reversed-phase chromatography on ExionAC LC coupled with ZenoTOF 7600 (SCIEX) operating in positive electrospray ionization scheduled MRMhr mode acquiring full MS/MS spectra for each compound. Developed processing method use multi-level confirmation and combined scoring based on HR data where result is affected by 5 criteria that have different decision weights: MS/MS library confirmation (50%), precursor ion mass defect (20%), quantifier ion mass defect (20%), precursor ion isotope pattern (5%) and retention time (5%). Each criterium contributes in the combined score calculation and has its own range of 3-level acceptance in ppm, % or seconds, respectively. The cut-off point of combined score is estimated at 70% after series of analysis and allows flawless reporting of compounds from DRUID list. Data were processed in SCIEX OS software.

Bioanalytics: Figure 1. Procedure of blood samples preparation.Bioanalytics: Figure 1. Procedure of blood samples preparation.

Results

The method was validated separately for blood and blood collected on VAMS and fulfilled the following criteria for each analyte: linearity (R ≥ 0.995), working range (LLOQ – 50 ng/ml), reproducibility (%CV ≤ 15%), accuracy (80 – 120%) and recovery (80 – 120%). For majority of analytes included in the method LLOQ was in the range 0.01- 0.05 ng/ml (ex. Diazepam, Flunitrazepam, Kodeine, Morphine, MDA) for blood and 0.05-0.1 ng/ml for VAMS sampler. For analytes such as Tramadol, Fentanyl, Methadone and Cocaine the LLOQ ranged between 0.001- 0.005 ng/ml for blood and 0.01-0.05 for VAMS. The method was successfully applied to routine analysis of blood samples.

Bioanalytics: Table 1. Parameters applied in LC-MS_MS methodBioanalytics: Table 1. Parameters applied in LC-MS_MS methodBioanalytics: Figure 2. Chromatogram presenting LC-MS_MS analysis of 27 psychoactiv compounds from DRUID list.Bioanalytics: Figure 2. Chromatogram presenting LC-MS_MS analysis of 27 psychoactiv compounds from DRUID list.Bioanalytics: Figure 3. Criteria applied in developed processing method using a multi-level confirmation and combined scoring based on HR data.Bioanalytics: Figure 3. Criteria applied in developed processing method using a multi-level confirmation and combined scoring based on HR data.Bioanalytics: Table 2. Results of quantitative methods validation.Bioanalytics: Table 2. Results of quantitative methods validation.Bioanalytics: Figure 4. Example of false positive result exclusion for Metamphetamine in unspiked venous blood sample due to multi-level confirmation method.Bioanalytics: Figure 4. Example of false positive result exclusion for Metamphetamine in unspiked venous blood sample due to multi-level confirmation method.

Discussions and Conclusions

A quantitative LC-MS/MS method was validated according to the international recommendations. The greatest advantage of presented method is its high specificity and extremely low Limits of Quantitation. Most of described in literature LC-MS/MS methods used for psychoactive compounds quantification are based on MRM scanning mode with triple quadrupole instruments. Such approach does not allow to obtain sufficiently high specificity because of difficult data interpretation at low concentrations of analytes in real-life samples where MRM ratio and matrix interferences leads to data misinterpretation. Developed method allows sensitive, specific and false positive resistant HR-MS/MS quantitation of 27 psychoactive compounds in blood and blood collected by VAMS.

Bioanalytic
LinkedIn Logo
 

Related content

Determination of Authenticity of Manuka Honey Using the MALDI-8030 Benchtop Linear MALDI-TOF Mass Spectrometer

Applications
| 2026 | Shimadzu
Instrumentation
MALDI, LC/MS, LC/TOF
Manufacturer
Shimadzu
Industries
Food & Agriculture

Analysis of Inorganic Anions in Drinking Water According to EPA Method 300.1 Using Nexera IC -Part A

Applications
| 2026 | Shimadzu
Instrumentation
Ion chromatography
Manufacturer
Shimadzu
Industries
Food & Agriculture

Quality Evaluation of mRNA by Electrophoresis

Applications
| 2026 | Shimadzu
Instrumentation
Capillary electrophoresis
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

LC/MS dMRM Method Refinement Expands Targeted Lipidomics Studies from Plasma to Cells and Tissues

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Lipidomics, Clinical Research

Sensitive Detection of Aflatoxins by the Agilent 1290 Infinity III Fluorescence Detector

Applications
| 2026 | Agilent Technologies
Instrumentation
HPLC
Manufacturer
Agilent Technologies
Industries
Food & Agriculture
 

Related articles

Introducing the new Thermo Scientific TSQ Certis Triple Quadrupole Mass Spectrometer
Article | Product

Introducing the new Thermo Scientific TSQ Certis Triple Quadrupole Mass Spectrometer

Thermo Scientific TSQ Certis Triple Quadrupole MS delivers rugged uptime, next-gen quantitative performance, and high-throughput LC-MS/MS for routine, clinical, PFAS, and biopharma labs.
Thermo Fisher Scientific
tag
share
more
ISC 2026 Deadline for abstract submission
Article | Events

ISC 2026 Deadline for abstract submission

Only 8 days left to submit your abstract for an oral presentation at ISC 2026 in Prague. Secure your slot—and your chance to present in Tutorials & Young Speakers.
International Symposium on Chromatography - (ISC)
tag
share
more
Oligos Made Easy - Part 5: SEC
Article | Academy

Oligos Made Easy - Part 5: SEC

Learn how SEC streamlines oligonucleotide purification. From pore size selection to flow optimization, discover practical tips for desalting, buffer exchange, and clean size-based separation.
KNAUER
tag
share
more
News from LabRulezLCMS Library - Week 10, 2026
Article | Application

News from LabRulezLCMS Library - Week 10, 2026

This week we bring you application notes by KNAUER, Shimadzu, Thermo Fisher Scientific and Waters Corporation and technical note by Agilent Technologies!
LabRulez
tag
share
more
 

Related content

Determination of Authenticity of Manuka Honey Using the MALDI-8030 Benchtop Linear MALDI-TOF Mass Spectrometer

Applications
| 2026 | Shimadzu
Instrumentation
MALDI, LC/MS, LC/TOF
Manufacturer
Shimadzu
Industries
Food & Agriculture

Analysis of Inorganic Anions in Drinking Water According to EPA Method 300.1 Using Nexera IC -Part A

Applications
| 2026 | Shimadzu
Instrumentation
Ion chromatography
Manufacturer
Shimadzu
Industries
Food & Agriculture

Quality Evaluation of mRNA by Electrophoresis

Applications
| 2026 | Shimadzu
Instrumentation
Capillary electrophoresis
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

LC/MS dMRM Method Refinement Expands Targeted Lipidomics Studies from Plasma to Cells and Tissues

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Lipidomics, Clinical Research

Sensitive Detection of Aflatoxins by the Agilent 1290 Infinity III Fluorescence Detector

Applications
| 2026 | Agilent Technologies
Instrumentation
HPLC
Manufacturer
Agilent Technologies
Industries
Food & Agriculture
 

Related articles

Introducing the new Thermo Scientific TSQ Certis Triple Quadrupole Mass Spectrometer
Article | Product

Introducing the new Thermo Scientific TSQ Certis Triple Quadrupole Mass Spectrometer

Thermo Scientific TSQ Certis Triple Quadrupole MS delivers rugged uptime, next-gen quantitative performance, and high-throughput LC-MS/MS for routine, clinical, PFAS, and biopharma labs.
Thermo Fisher Scientific
tag
share
more
ISC 2026 Deadline for abstract submission
Article | Events

ISC 2026 Deadline for abstract submission

Only 8 days left to submit your abstract for an oral presentation at ISC 2026 in Prague. Secure your slot—and your chance to present in Tutorials & Young Speakers.
International Symposium on Chromatography - (ISC)
tag
share
more
Oligos Made Easy - Part 5: SEC
Article | Academy

Oligos Made Easy - Part 5: SEC

Learn how SEC streamlines oligonucleotide purification. From pore size selection to flow optimization, discover practical tips for desalting, buffer exchange, and clean size-based separation.
KNAUER
tag
share
more
News from LabRulezLCMS Library - Week 10, 2026
Article | Application

News from LabRulezLCMS Library - Week 10, 2026

This week we bring you application notes by KNAUER, Shimadzu, Thermo Fisher Scientific and Waters Corporation and technical note by Agilent Technologies!
LabRulez
tag
share
more
 

Related content

Determination of Authenticity of Manuka Honey Using the MALDI-8030 Benchtop Linear MALDI-TOF Mass Spectrometer

Applications
| 2026 | Shimadzu
Instrumentation
MALDI, LC/MS, LC/TOF
Manufacturer
Shimadzu
Industries
Food & Agriculture

Analysis of Inorganic Anions in Drinking Water According to EPA Method 300.1 Using Nexera IC -Part A

Applications
| 2026 | Shimadzu
Instrumentation
Ion chromatography
Manufacturer
Shimadzu
Industries
Food & Agriculture

Quality Evaluation of mRNA by Electrophoresis

Applications
| 2026 | Shimadzu
Instrumentation
Capillary electrophoresis
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

LC/MS dMRM Method Refinement Expands Targeted Lipidomics Studies from Plasma to Cells and Tissues

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Lipidomics, Clinical Research

Sensitive Detection of Aflatoxins by the Agilent 1290 Infinity III Fluorescence Detector

Applications
| 2026 | Agilent Technologies
Instrumentation
HPLC
Manufacturer
Agilent Technologies
Industries
Food & Agriculture
 

Related articles

Introducing the new Thermo Scientific TSQ Certis Triple Quadrupole Mass Spectrometer
Article | Product

Introducing the new Thermo Scientific TSQ Certis Triple Quadrupole Mass Spectrometer

Thermo Scientific TSQ Certis Triple Quadrupole MS delivers rugged uptime, next-gen quantitative performance, and high-throughput LC-MS/MS for routine, clinical, PFAS, and biopharma labs.
Thermo Fisher Scientific
tag
share
more
ISC 2026 Deadline for abstract submission
Article | Events

ISC 2026 Deadline for abstract submission

Only 8 days left to submit your abstract for an oral presentation at ISC 2026 in Prague. Secure your slot—and your chance to present in Tutorials & Young Speakers.
International Symposium on Chromatography - (ISC)
tag
share
more
Oligos Made Easy - Part 5: SEC
Article | Academy

Oligos Made Easy - Part 5: SEC

Learn how SEC streamlines oligonucleotide purification. From pore size selection to flow optimization, discover practical tips for desalting, buffer exchange, and clean size-based separation.
KNAUER
tag
share
more
News from LabRulezLCMS Library - Week 10, 2026
Article | Application

News from LabRulezLCMS Library - Week 10, 2026

This week we bring you application notes by KNAUER, Shimadzu, Thermo Fisher Scientific and Waters Corporation and technical note by Agilent Technologies!
LabRulez
tag
share
more
 

Related content

Determination of Authenticity of Manuka Honey Using the MALDI-8030 Benchtop Linear MALDI-TOF Mass Spectrometer

Applications
| 2026 | Shimadzu
Instrumentation
MALDI, LC/MS, LC/TOF
Manufacturer
Shimadzu
Industries
Food & Agriculture

Analysis of Inorganic Anions in Drinking Water According to EPA Method 300.1 Using Nexera IC -Part A

Applications
| 2026 | Shimadzu
Instrumentation
Ion chromatography
Manufacturer
Shimadzu
Industries
Food & Agriculture

Quality Evaluation of mRNA by Electrophoresis

Applications
| 2026 | Shimadzu
Instrumentation
Capillary electrophoresis
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

LC/MS dMRM Method Refinement Expands Targeted Lipidomics Studies from Plasma to Cells and Tissues

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Lipidomics, Clinical Research

Sensitive Detection of Aflatoxins by the Agilent 1290 Infinity III Fluorescence Detector

Applications
| 2026 | Agilent Technologies
Instrumentation
HPLC
Manufacturer
Agilent Technologies
Industries
Food & Agriculture
 

Related articles

Introducing the new Thermo Scientific TSQ Certis Triple Quadrupole Mass Spectrometer
Article | Product

Introducing the new Thermo Scientific TSQ Certis Triple Quadrupole Mass Spectrometer

Thermo Scientific TSQ Certis Triple Quadrupole MS delivers rugged uptime, next-gen quantitative performance, and high-throughput LC-MS/MS for routine, clinical, PFAS, and biopharma labs.
Thermo Fisher Scientific
tag
share
more
ISC 2026 Deadline for abstract submission
Article | Events

ISC 2026 Deadline for abstract submission

Only 8 days left to submit your abstract for an oral presentation at ISC 2026 in Prague. Secure your slot—and your chance to present in Tutorials & Young Speakers.
International Symposium on Chromatography - (ISC)
tag
share
more
Oligos Made Easy - Part 5: SEC
Article | Academy

Oligos Made Easy - Part 5: SEC

Learn how SEC streamlines oligonucleotide purification. From pore size selection to flow optimization, discover practical tips for desalting, buffer exchange, and clean size-based separation.
KNAUER
tag
share
more
News from LabRulezLCMS Library - Week 10, 2026
Article | Application

News from LabRulezLCMS Library - Week 10, 2026

This week we bring you application notes by KNAUER, Shimadzu, Thermo Fisher Scientific and Waters Corporation and technical note by Agilent Technologies!
LabRulez
tag
share
more
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike