Author
Bioanalytic
Bioanalytic
Bioanalytic started its operations in 1998. The company was born from a passion for science and the need to provide innovative solutions in the laboratory equipment market, from a small business to a dynamically developing company with an established position.
Tags
Article
Poster
Health
LinkedIn Logo

How sure you can be of the results of quantification of psychoactive compounds in blood?

Th, 23.1.2025
| Original article from: Bioanalytic
In this work we show a HR-MS/MS method for a sensitive detection of 27 psychoactive compounds with high confidence in venous blood and blood collected on a volumetric absorptive microsampling (VAMS) probe.
<p><strong>Bioanalytic:</strong> How sure you can be of the results of quantification of psychoactive compounds in blood?</p>

Bioanalytic: How sure you can be of the results of quantification of psychoactive compounds in blood?

Anna Lenartowicz (1); Julia Mironenka (1); Adrian Soboń (1,2); Rafał Szewczyk (1,2); Katarzyna Krupczyńska-Stopa (1,2); Maciej Stopa (1,2); Andrzej Kwaśnica (3)
1 – LabExperts sp. z o. o., Gdańsk, Poland; 2 – Bioanalytic sp. z o. o., Gdańsk, Poland; 3 – Lab4Tox sp. z o. o., Wrocław, Poland

Introduction

Compound presence confirmation is one of the key aspects of targeted and quantitative analysis in forensics applications. High resolution tandem mass spectrometry (HR-MS/MS) may become a major tool for this kind of analysis because of its mass accuracy resulting in unparallel specificity, all combined with broad linearity and scanning speed achieved in the newest hardware on the market. In this work we show a modern HR-MS/MS method for a sensitive detection of 27 analytes with high confidence in venous blood and blood collected on a volumetric absorptive microsampling (VAMS) probe. Analytes include: Tramadol, Morphine, Fentanyl, Methadone, Codeine, Alprazolam, Diazepam, Flunitrazepam, Lorazepam, Oxazepam, Zolpiclone, Clonazepam, Nordiazepam, Zolpidem, Hydroxyzine, Amphetamine, Methamphetamine, MDA, MDMA, MDEA, THC, Cocaine, 6-acetylmorphine, 7-aminoflunitrazepam, 7-aminoclonazepam, Benzoylecgonine, THC-COOH.

Materials and Methods

Briefly, sample preparation included: spiking of internal standards, protein precipitation and extraction using acetonitrile:methanol (1:1) with 0.1% formic acid, evaporation under nitrogen stream and reconstitution in LC mobile phase. Compounds were analyzed using reversed-phase chromatography on ExionAC LC coupled with ZenoTOF 7600 (SCIEX) operating in positive electrospray ionization scheduled MRMhr mode acquiring full MS/MS spectra for each compound. Developed processing method use multi-level confirmation and combined scoring based on HR data where result is affected by 5 criteria that have different decision weights: MS/MS library confirmation (50%), precursor ion mass defect (20%), quantifier ion mass defect (20%), precursor ion isotope pattern (5%) and retention time (5%). Each criterium contributes in the combined score calculation and has its own range of 3-level acceptance in ppm, % or seconds, respectively. The cut-off point of combined score is estimated at 70% after series of analysis and allows flawless reporting of compounds from DRUID list. Data were processed in SCIEX OS software.

Bioanalytics: Figure 1. Procedure of blood samples preparation.Bioanalytics: Figure 1. Procedure of blood samples preparation.

Results

The method was validated separately for blood and blood collected on VAMS and fulfilled the following criteria for each analyte: linearity (R ≥ 0.995), working range (LLOQ – 50 ng/ml), reproducibility (%CV ≤ 15%), accuracy (80 – 120%) and recovery (80 – 120%). For majority of analytes included in the method LLOQ was in the range 0.01- 0.05 ng/ml (ex. Diazepam, Flunitrazepam, Kodeine, Morphine, MDA) for blood and 0.05-0.1 ng/ml for VAMS sampler. For analytes such as Tramadol, Fentanyl, Methadone and Cocaine the LLOQ ranged between 0.001- 0.005 ng/ml for blood and 0.01-0.05 for VAMS. The method was successfully applied to routine analysis of blood samples.

Bioanalytics: Table 1. Parameters applied in LC-MS_MS methodBioanalytics: Table 1. Parameters applied in LC-MS_MS methodBioanalytics: Figure 2. Chromatogram presenting LC-MS_MS analysis of 27 psychoactiv compounds from DRUID list.Bioanalytics: Figure 2. Chromatogram presenting LC-MS_MS analysis of 27 psychoactiv compounds from DRUID list.Bioanalytics: Figure 3. Criteria applied in developed processing method using a multi-level confirmation and combined scoring based on HR data.Bioanalytics: Figure 3. Criteria applied in developed processing method using a multi-level confirmation and combined scoring based on HR data.Bioanalytics: Table 2. Results of quantitative methods validation.Bioanalytics: Table 2. Results of quantitative methods validation.Bioanalytics: Figure 4. Example of false positive result exclusion for Metamphetamine in unspiked venous blood sample due to multi-level confirmation method.Bioanalytics: Figure 4. Example of false positive result exclusion for Metamphetamine in unspiked venous blood sample due to multi-level confirmation method.

Discussions and Conclusions

A quantitative LC-MS/MS method was validated according to the international recommendations. The greatest advantage of presented method is its high specificity and extremely low Limits of Quantitation. Most of described in literature LC-MS/MS methods used for psychoactive compounds quantification are based on MRM scanning mode with triple quadrupole instruments. Such approach does not allow to obtain sufficiently high specificity because of difficult data interpretation at low concentrations of analytes in real-life samples where MRM ratio and matrix interferences leads to data misinterpretation. Developed method allows sensitive, specific and false positive resistant HR-MS/MS quantitation of 27 psychoactive compounds in blood and blood collected by VAMS.

Bioanalytic
LinkedIn Logo
 

Related content

Simultaneous Quantitation and Discovery analysis: Combining targeted and untargeted metabolomics on Orbitrap mass spectrometers

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Metabolomics

Analysis of Per- and Polyfluoroalkyl Substances (PFAS) in Wastewater

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Environmental

Non-Targeted Screening of Biosolids with the Xevo™ MRT Mass Spectrometer Reveals New Isoforms of PFAS

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Waters
Industries
Environmental

High Resolution Characterization of Lipid Nanoparticles Using the Xevo™ Charge Detection Mass Spectrometry (CDMS) Instrument - Single Particle Mass Analysis of Intact LNP-mRNA Formulations

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/HRMS, Particle characterization, LC/IT
Manufacturer
Waters
Industries
Lipidomics

Out-of-the-box workflow for PFAS quantitation using a fullscan high-resolution approach with the Orbitrap Exploris EFOX Mass Detector

Applications
| 2025 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Environmental
 

Related articles

From venous blood to VAMS – adaptation of a commercial CE-IVD assay kit for the determination of Tacrolimus, Sirolimus, Everolimus and Cyclosporin A
Article | Poster

From venous blood to VAMS – adaptation of a commercial CE-IVD assay kit for the determination of Tacrolimus, Sirolimus, Everolimus and Cyclosporin A

The study checked if optimization of ready-to-use kit for determination of Tacrolimus, Sirolimus, Everolimus and Cyclosporin A in venous blood can be successfully applied for VAMS-collected blood.
Bioanalytic
tag
share
more
How to improve the precision of analysis – semi-automated sample preparation for psychoactive compounds quantification in human plasma
Article | Poster

How to improve the precision of analysis – semi-automated sample preparation for psychoactive compounds quantification in human plasma

This work shows the effective translation from manual method to semi-automated procedure of determination of 34 psychoactive compounds from human plasma using LC-MS/MS method.
Bioanalytic
tag
share
more
How to deal with sweet matrix? – a method for LC-MS/MS analysis of antibiotics in honey, regardless of its kind
Article | Poster

How to deal with sweet matrix? – a method for LC-MS/MS analysis of antibiotics in honey, regardless of its kind

In this work we have focused on the development of highly reproducible and precise method of 57 antibiotics determination by LC-MS/MS in honey, regardless of its origin.
Bioanalytic
tag
share
more
HR-MS/MS EAD and CID fragmentation leads to selective, sensitive and reliable quantitation of anabolic steroids in urine
Article | Poster

HR-MS/MS EAD and CID fragmentation leads to selective, sensitive and reliable quantitation of anabolic steroids in urine

HRMS offers a powerful tool to detect and identify drugs using mass defect data on precursor and quantifier ion with parallel spectral library matching followed by quantitative analysis at low levels.
Bioanalytic
tag
share
more
 

Related content

Simultaneous Quantitation and Discovery analysis: Combining targeted and untargeted metabolomics on Orbitrap mass spectrometers

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Metabolomics

Analysis of Per- and Polyfluoroalkyl Substances (PFAS) in Wastewater

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Environmental

Non-Targeted Screening of Biosolids with the Xevo™ MRT Mass Spectrometer Reveals New Isoforms of PFAS

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Waters
Industries
Environmental

High Resolution Characterization of Lipid Nanoparticles Using the Xevo™ Charge Detection Mass Spectrometry (CDMS) Instrument - Single Particle Mass Analysis of Intact LNP-mRNA Formulations

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/HRMS, Particle characterization, LC/IT
Manufacturer
Waters
Industries
Lipidomics

Out-of-the-box workflow for PFAS quantitation using a fullscan high-resolution approach with the Orbitrap Exploris EFOX Mass Detector

Applications
| 2025 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Environmental
 

Related articles

From venous blood to VAMS – adaptation of a commercial CE-IVD assay kit for the determination of Tacrolimus, Sirolimus, Everolimus and Cyclosporin A
Article | Poster

From venous blood to VAMS – adaptation of a commercial CE-IVD assay kit for the determination of Tacrolimus, Sirolimus, Everolimus and Cyclosporin A

The study checked if optimization of ready-to-use kit for determination of Tacrolimus, Sirolimus, Everolimus and Cyclosporin A in venous blood can be successfully applied for VAMS-collected blood.
Bioanalytic
tag
share
more
How to improve the precision of analysis – semi-automated sample preparation for psychoactive compounds quantification in human plasma
Article | Poster

How to improve the precision of analysis – semi-automated sample preparation for psychoactive compounds quantification in human plasma

This work shows the effective translation from manual method to semi-automated procedure of determination of 34 psychoactive compounds from human plasma using LC-MS/MS method.
Bioanalytic
tag
share
more
How to deal with sweet matrix? – a method for LC-MS/MS analysis of antibiotics in honey, regardless of its kind
Article | Poster

How to deal with sweet matrix? – a method for LC-MS/MS analysis of antibiotics in honey, regardless of its kind

In this work we have focused on the development of highly reproducible and precise method of 57 antibiotics determination by LC-MS/MS in honey, regardless of its origin.
Bioanalytic
tag
share
more
HR-MS/MS EAD and CID fragmentation leads to selective, sensitive and reliable quantitation of anabolic steroids in urine
Article | Poster

HR-MS/MS EAD and CID fragmentation leads to selective, sensitive and reliable quantitation of anabolic steroids in urine

HRMS offers a powerful tool to detect and identify drugs using mass defect data on precursor and quantifier ion with parallel spectral library matching followed by quantitative analysis at low levels.
Bioanalytic
tag
share
more
 

Related content

Simultaneous Quantitation and Discovery analysis: Combining targeted and untargeted metabolomics on Orbitrap mass spectrometers

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Metabolomics

Analysis of Per- and Polyfluoroalkyl Substances (PFAS) in Wastewater

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Environmental

Non-Targeted Screening of Biosolids with the Xevo™ MRT Mass Spectrometer Reveals New Isoforms of PFAS

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Waters
Industries
Environmental

High Resolution Characterization of Lipid Nanoparticles Using the Xevo™ Charge Detection Mass Spectrometry (CDMS) Instrument - Single Particle Mass Analysis of Intact LNP-mRNA Formulations

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/HRMS, Particle characterization, LC/IT
Manufacturer
Waters
Industries
Lipidomics

Out-of-the-box workflow for PFAS quantitation using a fullscan high-resolution approach with the Orbitrap Exploris EFOX Mass Detector

Applications
| 2025 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Environmental
 

Related articles

From venous blood to VAMS – adaptation of a commercial CE-IVD assay kit for the determination of Tacrolimus, Sirolimus, Everolimus and Cyclosporin A
Article | Poster

From venous blood to VAMS – adaptation of a commercial CE-IVD assay kit for the determination of Tacrolimus, Sirolimus, Everolimus and Cyclosporin A

The study checked if optimization of ready-to-use kit for determination of Tacrolimus, Sirolimus, Everolimus and Cyclosporin A in venous blood can be successfully applied for VAMS-collected blood.
Bioanalytic
tag
share
more
How to improve the precision of analysis – semi-automated sample preparation for psychoactive compounds quantification in human plasma
Article | Poster

How to improve the precision of analysis – semi-automated sample preparation for psychoactive compounds quantification in human plasma

This work shows the effective translation from manual method to semi-automated procedure of determination of 34 psychoactive compounds from human plasma using LC-MS/MS method.
Bioanalytic
tag
share
more
How to deal with sweet matrix? – a method for LC-MS/MS analysis of antibiotics in honey, regardless of its kind
Article | Poster

How to deal with sweet matrix? – a method for LC-MS/MS analysis of antibiotics in honey, regardless of its kind

In this work we have focused on the development of highly reproducible and precise method of 57 antibiotics determination by LC-MS/MS in honey, regardless of its origin.
Bioanalytic
tag
share
more
HR-MS/MS EAD and CID fragmentation leads to selective, sensitive and reliable quantitation of anabolic steroids in urine
Article | Poster

HR-MS/MS EAD and CID fragmentation leads to selective, sensitive and reliable quantitation of anabolic steroids in urine

HRMS offers a powerful tool to detect and identify drugs using mass defect data on precursor and quantifier ion with parallel spectral library matching followed by quantitative analysis at low levels.
Bioanalytic
tag
share
more
 

Related content

Simultaneous Quantitation and Discovery analysis: Combining targeted and untargeted metabolomics on Orbitrap mass spectrometers

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Metabolomics

Analysis of Per- and Polyfluoroalkyl Substances (PFAS) in Wastewater

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Environmental

Non-Targeted Screening of Biosolids with the Xevo™ MRT Mass Spectrometer Reveals New Isoforms of PFAS

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Waters
Industries
Environmental

High Resolution Characterization of Lipid Nanoparticles Using the Xevo™ Charge Detection Mass Spectrometry (CDMS) Instrument - Single Particle Mass Analysis of Intact LNP-mRNA Formulations

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/HRMS, Particle characterization, LC/IT
Manufacturer
Waters
Industries
Lipidomics

Out-of-the-box workflow for PFAS quantitation using a fullscan high-resolution approach with the Orbitrap Exploris EFOX Mass Detector

Applications
| 2025 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Environmental
 

Related articles

From venous blood to VAMS – adaptation of a commercial CE-IVD assay kit for the determination of Tacrolimus, Sirolimus, Everolimus and Cyclosporin A
Article | Poster

From venous blood to VAMS – adaptation of a commercial CE-IVD assay kit for the determination of Tacrolimus, Sirolimus, Everolimus and Cyclosporin A

The study checked if optimization of ready-to-use kit for determination of Tacrolimus, Sirolimus, Everolimus and Cyclosporin A in venous blood can be successfully applied for VAMS-collected blood.
Bioanalytic
tag
share
more
How to improve the precision of analysis – semi-automated sample preparation for psychoactive compounds quantification in human plasma
Article | Poster

How to improve the precision of analysis – semi-automated sample preparation for psychoactive compounds quantification in human plasma

This work shows the effective translation from manual method to semi-automated procedure of determination of 34 psychoactive compounds from human plasma using LC-MS/MS method.
Bioanalytic
tag
share
more
How to deal with sweet matrix? – a method for LC-MS/MS analysis of antibiotics in honey, regardless of its kind
Article | Poster

How to deal with sweet matrix? – a method for LC-MS/MS analysis of antibiotics in honey, regardless of its kind

In this work we have focused on the development of highly reproducible and precise method of 57 antibiotics determination by LC-MS/MS in honey, regardless of its origin.
Bioanalytic
tag
share
more
HR-MS/MS EAD and CID fragmentation leads to selective, sensitive and reliable quantitation of anabolic steroids in urine
Article | Poster

HR-MS/MS EAD and CID fragmentation leads to selective, sensitive and reliable quantitation of anabolic steroids in urine

HRMS offers a powerful tool to detect and identify drugs using mass defect data on precursor and quantifier ion with parallel spectral library matching followed by quantitative analysis at low levels.
Bioanalytic
tag
share
more
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike