LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

RECIPE ClinMass® TDM 200 Kit System

Brochures and specifications |  | RECIPEInstrumentation
Sample Preparation, Consumables
Industries
Clinical Research
Manufacturer
RECIPE

Summary

Significance of the Topic

Therapeutic drug monitoring (TDM) plays a critical role in optimizing dosage for drugs with narrow therapeutic windows, ensuring efficacy while preventing toxicity.
This approach reduces adverse drug reactions, shortens hospitalization, and yields cost savings in clinical practice.

Study Objectives and Overview

This whitepaper introduces the RECIPE ClinMass® TDM 200 Kit System, an integrated LC-MS/MS solution designed to streamline and standardize TDM workflows.
The system targets eight major drug classes using a single analytical column and offers eight dedicated add-on sets covering benzodiazepines, tricyclic antidepressants, antiepileptics, antidepressants, neuroleptics, antimycotics, mycophenolic acid, and immunosuppressants.

Methodology and Instrumentation

Sample Preparation:
  • Simple one-step protein precipitation: mix 50 µl sample with 100 µl precipitant containing internal standards, centrifuge, inject supernatant.
Chromatography and Detection:
  • Reversed-phase LC separation on a single column for all analyte classes.
  • Tandem mass spectrometry (LC-MS/MS) operated in multiple reaction monitoring mode.
  • Short run times (approx. 2–7 minutes per class) and minimal instrument occupancy.

Key Results and Discussion

Chromatographic Performance:
  • All target analytes eluted between 0.4 and 7.0 min with consistent peak shape and resolution.
  • Intensity profiles demonstrated stable response factors across concentration ranges.
Analytical Metrics:
  • Linear calibration curves achieved for each compound within therapeutic ranges.
  • Limits of quantification suitable for clinical decision-making.
System Robustness:
  • No method splitting required; single analytical run per drug class increases throughput.
  • Reproducible retention times and signal intensities support routine use.

Benefits and Practical Applications

  • Standardized workflow reduces method development time and training requirements.
  • Lower consumable usage and waste streamline laboratory logistics.
  • Compact refrigerated storage for reagents minimizes footprint.
  • Enhanced patient care through rapid turnaround and precise dosing guidance.

Future Trends and Potential Applications

Emerging directions in TDM include integration with clinical decision support systems, expansion to novel biomarkers, and greater automation in sample handling.
Advances in high-throughput LC-MS/MS platforms and AI-driven data analysis may further improve personalized therapy management.

Conclusion

The ClinMass® TDM 200 Kit System delivers a comprehensive, efficient, and robust workflow for therapeutic drug monitoring across multiple drug classes.
Its one-step preparation and single-column LC-MS/MS approach support high laboratory throughput, consistent performance, and improved patient outcomes.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
RECIPE HPLC & LC-MS/MS IVD Complete Kits - Product Catalogue I
HPLC & LC-MS/MS IVD Complete Kits Product Catalogue I 2020 / 2021 Editorial Dear customers, We are proud to present our new RECIPE product catalogues “IVD Complete Kits” and ua it Assuran e re e tin our en ar ed…
Key words
ophi, ophiontro, ontroeve, eveeru, eruution, utionith, ithana, anahro, hrotandard, tandardass, assrator, ratorent, entnterna, nternatdm, tdmrine
RECIPE Calibrators & Controls Quality Assurance - Product Catalogue II
Calibrators & Controls Quality Assurance Product Catalogue II 2020 / 2021 Quality Assurance ClinCal® Calibrators are designed for the calibra­ tion of the analytical system (HPLC, LC-MS/MS, photometry, etc). The analytes of ClinCal® Cali­ brators are available in matrices (urine,…
Key words
clinchek, clinchekclincal, clincalelements, elementsantidepressants, antidepressantstrace, traceneuroleptics, neurolepticsquantity, quantitybenzodiazepines, benzodiazepinesamino, aminoantiretrovirals, antiretroviralsdescription, descriptionacids, acidstricyclic, tricyclicantiepileptics, antiepilepticsblood
Quantification of 36 antidepressants in human plasma by LC-HRAM-MS for clinical research
TECHNICAL NOTE 000272 Quantification of 36 antidepressants in human plasma by LC-HRAM-MS for clinical research Authors: Gaëtan Renoulin1, Claudio De Nardi2, Mariana Barcenas1 1 Thermo Fisher Scientific, Les Ulis, France 2 Thermo Fisher Scientific, Reinach, Switzerland Keywords: Orbitrap Exploris 120…
Key words
level, levelintensity, intensitybupropion, bupropionmin, mindesmethylsertaline, desmethylsertalinedesmethylfluoxetine, desmethylfluoxetinedesmethylmianserine, desmethylmianserineguanfacine, guanfacineclomethiazole, clomethiazoleagomelatine, agomelatinevortioxetine, vortioxetinedesmethylcitalopram, desmethylcitalopramreboxetine, reboxetinecalculated, calculatedmoclobemide
Fully automated platform for TDM analysis in serum samples
PO-CON1786E Fully automated platform for TDM analysis in serum samples MSACL 2017 Claudio Ghilardi1, Davide Vecchietti1, Katharina Kern2, Stephane Moreau3, Isabel Cabruja1 1 Shimadzu Italia, Milano, Italy, 2 3 RECIPE Chemicals + Instruments GmbH, Munich, Germany, Shimadzu Europe GmbH, Duisburg,…
Key words
tdm, tdmserum, serumneuroleptics, neurolepticsantiepileptics, antiepilepticsfully, fullyplatform, platformautomated, automateddrugs, drugstricyclic, tricyclicmrm, mrmsamples, samplesantidepressant, antidepressantesi, esiclozapine, clozapineantidepressants
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike