Installation Instruction for ProfIC Vario 1 PCR-UV/VIS
Manuals | | MetrohmInstrumentation
Ion chromatography with post-column reaction UV/VIS detection delivers automated, sensitive analysis of UV/VIS-active analytes, crucial for routine quality control, environmental monitoring, and research laboratories.
This bulletin provides step-by-step instructions for installing and configuring the ProfIC Vario 1 PCR-UV/VIS system, including hardware assembly, software setup in MagIC Net, and method initialization.
Ion chromatography
IndustriesManufacturerMetrohm
Summary
Importance of Topic
Ion chromatography with post-column reaction UV/VIS detection delivers automated, sensitive analysis of UV/VIS-active analytes, crucial for routine quality control, environmental monitoring, and research laboratories.
Objectives and Overview
This bulletin provides step-by-step instructions for installing and configuring the ProfIC Vario 1 PCR-UV/VIS system, including hardware assembly, software setup in MagIC Net, and method initialization.
Methodology and Instrumentation
- Software Installation and Configuration
- Install MagIC Net via CD, accept default directories, restart Windows.
- Connect instruments via USB, assign names and device roles in configuration.
- Hardware Assembly
- Unpack IC module, reactor, detector, sample processor, eluent module, and accessories.
- Mount reactor and detector on or beneath IC tower, secure bottle holders, remove transport locks, connect leak sensor and drainage tubing.
- Attach sample processor: connect controller and power cables, install peristaltic pump tubing and capillaries, position swing head, install rack.
- Capillary Routing
- Eluent inlet to pump.
- Pump outlet to column inlet (0.25 mm ID).
- Column outlet to reactor Y-connector.
- PCR reagent via peristaltic pump to reactor second Y-port.
- Reactor outlet to detector inlet; detector outlet to waste collector.
- 940 Professional IC Vario 1
- 943 Professional Reactor Vario
- 944 Professional UV/VIS Detector Vario
- 858 Professional Sample Processor
- Optional: High-pressure pump (HPG), Dosino, Liquid Handling Station (LQH), Eluent Production Module (941)
Key Results and Discussion
After equilibration and method import, chromate (CrVI) calibration shows linear response (R²≈0.9999), reproducible detection down to 0.05 µg/L, and stable baselines. Comparison of PCR delivery methods demonstrates that high-pressure pumping yields lowest noise and best long-term stability, while Dosino offers automated rinsing at the expense of refill delays.Benefits and Practical Applications
- Fully automated sampling and derivatization reduce manual workload and contamination risk.
- High sensitivity and reproducibility support trace analysis in water quality, industrial process control, and pharmaceutical QA/QC.
- Modular configuration allows tailored reagent delivery and column selection.
Future Trends and Possible Applications
- Integration with advanced robotics and LIMS for high-throughput workflows.
- Miniaturized microreactor designs for lower reagent consumption.
- Implementation of real-time monitoring and AI-driven method optimization.
Conclusion
The ProfIC Vario 1 PCR-UV/VIS system offers a robust, versatile platform for automated post-column derivatization and UV/VIS detection, delivering reliable, high-sensitivity analyses adaptable to diverse laboratory needs.Reference
- Application Bulletin 363: Installation Instruction for ProfIC Vario 1 PCR-UV/VIS
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Installation instruction for ProfIC Vario 1 UV/VIS
|Metrohm|Manuals
Application Bulletin 362 Installation instruction for ProfIC Vario 1 UV/VIS The ProfIC Vario 1 UV/VIS is a Professional IC system for the fully automatic determination of UV/VIS active compounds. «ProfIC Vario 1» safely masters all routine tasks in ion chromatography.…
Key words
station, stationvario, varioprofessional, professionalconnect, connecthandling, handlingdesignation, designationprocessor, processorplace, placenow, nowscrew, screweluent, eluentlqh, lqhpeek, peekarticle, articlevis
Installation Instruction for ProfIC Vario 1 Cation
|Metrohm|Manuals
Application Bulletin 360 Installation Instruction for ProfIC Vario 1 Cation Table of contents The ProfIC Vario 1 Cation is a Professional IC Vario system for the fully automatic determination of non-suppressed cations or anions. «ProfIC Vario 1» safely masters all…
Key words
station, stationdesignation, designationhandling, handlingprocessor, processorperistaltic, peristalticconnect, connectconnected, connectedrinsing, rinsingnow, nowscrew, screweluent, eluentlqh, lqhliquid, liquidarticle, articledosino
Installation Instruction for ProfIC Vario 1 Anion
|Metrohm|Manuals
Application Bulletin 359 Installation Instruction for ProfIC Vario 1 Anion ProfIC Vario 1 Anion is a Professional IC Vario system for the fully automatic determination of anions or cations with sequential suppression. «ProfIC Vario 1» safely masters all routine tasks…
Key words
msm, msmrinsing, rinsingstation, stationcapillary, capillaryperistaltic, peristalticregeneration, regenerationconnected, connectedrotor, rotorpump, pumplabeled, labeledexemplary, exemplarysuppressor, suppressormcs, mcsdesignation, designationhandling
Installation Instruction for ProfIC Vario 1 Amperometry
|Metrohm|Manuals
Application Bulletin 364 Installation Instruction for ProfIC Vario 1 Amperometry ProfIC Vario 1 Amperometry is a Professional IC system for the fully automatic determination of electroactive compounds. «ProfIC Vario 1» safely masters all routine tasks in ion chromatography. It is…
Key words
cell, cellstation, stationconnect, connectscrew, screwamperometric, amperometriceluent, eluentdesignation, designationnow, nowhandling, handlingprocessor, processorperistaltic, peristalticelectroactive, electroactiveconnected, connectedyou, youadsorber