Cary 4000/5000/6000i UV-Vis spectrophotometer – Site Preparation Checklist
Manuals | 2016 | Agilent TechnologiesInstrumentation
Ensuring correct laboratory setup is critical for reliable performance and longevity of UV-Vis spectrophotometers. Proper bench space, environmental control, and utility services prevent instrument damage, maintain measurement accuracy, and support efficient workflows.
This checklist outlines the prerequisites for installing Agilent Cary 4000/5000/6000i spectrophotometers. It guides users through space allocation, environmental requirements, power setup, and necessary supplies to facilitate a smooth installation.
The document employs a structured checklist approach covering:
Bench Space and Weight Capacity
Adherence to these guidelines ensures:
Integration of spectrophotometers with automated sample handling and IoT-enabled environmental monitoring can further enhance reliability. Advances in software-driven diagnostics and remote support will streamline installation and maintenance. Sustainable laboratory practices, such as energy-efficient components and closed-loop nitrogen recycling, are expected to gain traction.
Thorough site preparation is a foundational step for successful UV-Vis spectrophotometer operation. Following the outlined checklist minimizes installation risks, preserves instrument integrity, and supports accurate analytical outcomes.
Agilent Cary 4000 UV-Vis spectrophotometer
Agilent Cary 5000 UV-Vis spectrophotometer
Agilent Cary 6000i UV-Vis spectrophotometer
Agilent Technologies. Cary 4000/5000/6000i UV-Vis Spectrophotometer – Site Preparation Checklist. Publication G9825-90000, Revision 2.0, November 2016.
NIR Spectroscopy, UV–VIS spectrophotometry
IndustriesManufacturerAgilent Technologies
Summary
Significance of Site Preparation
Ensuring correct laboratory setup is critical for reliable performance and longevity of UV-Vis spectrophotometers. Proper bench space, environmental control, and utility services prevent instrument damage, maintain measurement accuracy, and support efficient workflows.
Objectives and Overview
This checklist outlines the prerequisites for installing Agilent Cary 4000/5000/6000i spectrophotometers. It guides users through space allocation, environmental requirements, power setup, and necessary supplies to facilitate a smooth installation.
Methodology and Instrumentation
The document employs a structured checklist approach covering:
- Laboratory bench dimensions and weight capacity
- Ambient conditions (temperature, humidity, vibration, contamination control)
- Electrical power specifications (voltage, grounding, outlet placement)
- Optional nitrogen purging setup for enhanced optical performance
Main Requirements and Discussion
Bench Space and Weight Capacity
- Height: ~90 cm, stable support for up to 141 kg (packed)
- Clearance: ≥2 in at sides, ≥6 in rear, ≥8 in front for air circulation and accessory access
- Temperature: 20–25 °C ±2 °C; non-operating: 5–45 °C
- Humidity: ≤90% non-condensing; operating within specs: 15–80%
- Contaminant-free atmosphere; separate sample prep area to avoid vapors and particulates
- 100–240 VAC ±10%, 50–60 Hz; single-phase three-wire system
- Dedicated grounded outlet; avoid extension cords and interference sources
- Power consumption: max 300 VA (185 W)
- Quartz cuvettes (pair)
- Nitrogen purging system: dry, oil-free gas at 12–25 psi; tubing and manifold with flow meters
Benefits and Practical Applications
Adherence to these guidelines ensures:
- Optimal instrument stability and measurement precision
- Reduced downtime and maintenance needs
- Safe operation and compliance with warranty conditions
Future Trends and Potential Applications
Integration of spectrophotometers with automated sample handling and IoT-enabled environmental monitoring can further enhance reliability. Advances in software-driven diagnostics and remote support will streamline installation and maintenance. Sustainable laboratory practices, such as energy-efficient components and closed-loop nitrogen recycling, are expected to gain traction.
Conclusion
Thorough site preparation is a foundational step for successful UV-Vis spectrophotometer operation. Following the outlined checklist minimizes installation risks, preserves instrument integrity, and supports accurate analytical outcomes.
Použitá instrumentace
Agilent Cary 4000 UV-Vis spectrophotometer
Agilent Cary 5000 UV-Vis spectrophotometer
Agilent Cary 6000i UV-Vis spectrophotometer
Reference
Agilent Technologies. Cary 4000/5000/6000i UV-Vis Spectrophotometer – Site Preparation Checklist. Publication G9825-90000, Revision 2.0, November 2016.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent Cary 4000 5000 6000i UV-Vis-NIR - Site Preparation Checklist
2023|Agilent Technologies|Manuals
Agilent CrossLab Start Up Services Agilent Cary 4000 5000 6000i UV-Vis-NIR Site Preparation Checklist Thank you for purchasing an instrument from Agilent Technologies. CrossLab Start Up is focused on helping customers shorten the time it takes to start realizing the…
Key words
special, specialservice, servicecustomer, customersite, siteoperating, operatingrequirements, requirementsnitrogen, nitrogeninstrument, instrumentnotes, notesengineer, engineerpreparation, preparationyour, yourassembly, assemblymay, mayweight
Cary 7000 Universal Measurement System (UMS) – Site Preparation Checklist
2016|Agilent Technologies|Manuals
Cary 7000 Universal Measurement System (UMS) – Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site…
Key words
checklist, checklistsite, sitespecial, specialaccessory, accessoryoperating, operatinguniversal, universaltechnologies, technologiescustomer, customernotes, notesunpacked, unpackednitrogen, nitrogeninstrument, instrumentagilent, agilentpower, powerpreparation
Cary Eclipse Fluorescence spectrophotometer – Site Preparation Checklist
2012|Agilent Technologies|Manuals
Cary Eclipse Fluorescence spectrophotometer – Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is…
Key words
cary, caryeclipse, eclipsespectrophotometer, spectrophotometerchecklist, checklistsite, sitefluorescence, fluorescencespecial, specialoperating, operatingtechnologies, technologiescustomer, customernotes, notescomply, complyinstrument, instrumentagilent, agilentimposed
Agilent Cary 60 UV-Vis Spectrophotometer Site Preparation Checklist
2023|Agilent Technologies|Manuals
Agilent CrossLab Start Up Services Agilent Cary 60 UV-Vis Spectrophotometer Site Preparation Checklist Thank you for purchasing an instrument from Agilent Technologies. CrossLab Start Up is focused on helping customers shorten the time it takes to start realizing the full…
Key words
special, specialsite, sitecustomer, customerservice, servicenotes, notesengineer, engineerrequirements, requirementspreparation, preparationoperating, operatingweight, weightdissipation, dissipationdescription, descriptionconsumption, consumptionspecific, specificinstrument