Cary 4000/5000/6000i UV-Vis spectrophotometer – Site Preparation Checklist

Manuals | 2016 | Agilent TechnologiesInstrumentation
NIR Spectroscopy, UV–VIS spectrophotometry
Industries
Manufacturer
Agilent Technologies

Summary

Significance of Site Preparation


Ensuring correct laboratory setup is critical for reliable performance and longevity of UV-Vis spectrophotometers. Proper bench space, environmental control, and utility services prevent instrument damage, maintain measurement accuracy, and support efficient workflows.

Objectives and Overview


This checklist outlines the prerequisites for installing Agilent Cary 4000/5000/6000i spectrophotometers. It guides users through space allocation, environmental requirements, power setup, and necessary supplies to facilitate a smooth installation.

Methodology and Instrumentation


The document employs a structured checklist approach covering:
  • Laboratory bench dimensions and weight capacity
  • Ambient conditions (temperature, humidity, vibration, contamination control)
  • Electrical power specifications (voltage, grounding, outlet placement)
  • Optional nitrogen purging setup for enhanced optical performance
The primary instrument is the Agilent Cary UV-Vis spectrophotometer models 4000, 5000, and 6000i.

Main Requirements and Discussion


Bench Space and Weight Capacity
  • Height: ~90 cm, stable support for up to 141 kg (packed)
  • Clearance: ≥2 in at sides, ≥6 in rear, ≥8 in front for air circulation and accessory access
Environmental Conditions
  • Temperature: 20–25 °C ±2 °C; non-operating: 5–45 °C
  • Humidity: ≤90% non-condensing; operating within specs: 15–80%
  • Contaminant-free atmosphere; separate sample prep area to avoid vapors and particulates
Power and Utilities
  • 100–240 VAC ±10%, 50–60 Hz; single-phase three-wire system
  • Dedicated grounded outlet; avoid extension cords and interference sources
  • Power consumption: max 300 VA (185 W)
Optional Supplies
  • Quartz cuvettes (pair)
  • Nitrogen purging system: dry, oil-free gas at 12–25 psi; tubing and manifold with flow meters

Benefits and Practical Applications


Adherence to these guidelines ensures:
  • Optimal instrument stability and measurement precision
  • Reduced downtime and maintenance needs
  • Safe operation and compliance with warranty conditions

Future Trends and Potential Applications


Integration of spectrophotometers with automated sample handling and IoT-enabled environmental monitoring can further enhance reliability. Advances in software-driven diagnostics and remote support will streamline installation and maintenance. Sustainable laboratory practices, such as energy-efficient components and closed-loop nitrogen recycling, are expected to gain traction.

Conclusion


Thorough site preparation is a foundational step for successful UV-Vis spectrophotometer operation. Following the outlined checklist minimizes installation risks, preserves instrument integrity, and supports accurate analytical outcomes.

Použitá instrumentace


Agilent Cary 4000 UV-Vis spectrophotometer

Agilent Cary 5000 UV-Vis spectrophotometer

Agilent Cary 6000i UV-Vis spectrophotometer

Reference


Agilent Technologies. Cary 4000/5000/6000i UV-Vis Spectrophotometer – Site Preparation Checklist. Publication G9825-90000, Revision 2.0, November 2016.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent Cary 4000 5000 6000i UV-Vis-NIR - Site Preparation Checklist
Agilent CrossLab Start Up Services Agilent Cary 4000 5000 6000i UV-Vis-NIR Site Preparation Checklist Thank you for purchasing an instrument from Agilent Technologies. CrossLab Start Up is focused on helping customers shorten the time it takes to start realizing the…
Key words
special, specialservice, servicecustomer, customersite, siteoperating, operatingrequirements, requirementsnitrogen, nitrogeninstrument, instrumentnotes, notesengineer, engineerpreparation, preparationyour, yourassembly, assemblymay, mayweight
Cary 7000 Universal Measurement System (UMS) – Site Preparation Checklist
Cary 7000 Universal Measurement System (UMS) – Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site…
Key words
checklist, checklistsite, sitespecial, specialaccessory, accessoryoperating, operatinguniversal, universaltechnologies, technologiescustomer, customernotes, notesunpacked, unpackednitrogen, nitrogeninstrument, instrumentagilent, agilentpower, powerpreparation
Cary Eclipse Fluorescence spectrophotometer – Site Preparation Checklist
Cary Eclipse Fluorescence spectrophotometer – Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is…
Key words
cary, caryeclipse, eclipsespectrophotometer, spectrophotometerchecklist, checklistsite, sitefluorescence, fluorescencespecial, specialoperating, operatingtechnologies, technologiescustomer, customernotes, notescomply, complyinstrument, instrumentagilent, agilentimposed
Agilent Cary 60 UV-Vis Spectrophotometer Site Preparation Checklist
Agilent CrossLab Start Up Services Agilent Cary 60 UV-Vis Spectrophotometer Site Preparation Checklist Thank you for purchasing an instrument from Agilent Technologies. CrossLab Start Up is focused on helping customers shorten the time it takes to start realizing the full…
Key words
special, specialsite, sitecustomer, customerservice, servicenotes, notesengineer, engineerrequirements, requirementspreparation, preparationoperating, operatingweight, weightdissipation, dissipationdescription, descriptionconsumption, consumptionspecific, specificinstrument
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike