Metrosep C 4 (Column manual)
Manuals | 2017 | MetrohmInstrumentation
Ion chromatography of cations is essential for water analysis, pharmaceutical quality control, environmental and nuclear monitoring. The Metrosep C4 column provides a robust, versatile silica-based phase that separates alkali and alkaline earth metals, common amines and transition metals with high sensitivity and reproducibility. Reliable cation analysis supports quality assurance in laboratories and process control in various industries.
This summary distills the key information from the Metrosep C4 column manual, covering column specifications, startup and conditioning procedures, method parameters, troubleshooting guidance and a wide range of practical applications. It aims to help analysts implement and optimize this cation separation system for routine and advanced ion chromatographic tasks.
Practical examples highlight performance characteristics:
Integration of ion chromatography with mass spectrometry will enhance selectivity and trace-level detection. Continued development of high-throughput columns and ultrafast gradients will meet increasing demands for rapid environmental and process monitoring. Advanced inline sample manipulation, such as desalting and on-column reactions, will broaden applications in biopharmaceuticals, metabolomics and nuclear safety. Smart diagnostics and data-driven maintenance of columns promise to reduce downtime and operating costs.
The Metrosep C4 column offers a highly adaptable solution for routine and specialized cation analysis across diverse matrices. Its robust performance, combined with flexible eluent and temperature control, ensures reliable separations from standard drinking water to complex industrial and biological streams. Proper installation, conditioning and guard column use secure reproducible results and long service life, while inline sample preparation and advanced detection options extend capabilities for trace and high-throughput applications.
Consumables, Ion chromatography, LC columns
IndustriesManufacturerMetrohm
Summary
Importance of the Topic
Ion chromatography of cations is essential for water analysis, pharmaceutical quality control, environmental and nuclear monitoring. The Metrosep C4 column provides a robust, versatile silica-based phase that separates alkali and alkaline earth metals, common amines and transition metals with high sensitivity and reproducibility. Reliable cation analysis supports quality assurance in laboratories and process control in various industries.
Objectives and Study Overview
This summary distills the key information from the Metrosep C4 column manual, covering column specifications, startup and conditioning procedures, method parameters, troubleshooting guidance and a wide range of practical applications. It aims to help analysts implement and optimize this cation separation system for routine and advanced ion chromatographic tasks.
Applied Methodology and Instrumentation
- Separation on a silica gel column with carboxyl functional groups (5 µm particles); available in 2 mm and 4 mm internal diameters, lengths 50–250 mm.
- Standard eluent: 1.7 mmol/L nitric acid with 0.7 mmol/L dipicolinic acid; pH 2–7; optional oxalic acid or organic modifiers (acetone, acetonitrile) for selectivity tuning.
- Operating conditions: flow rates of 0.2 mL/min (2 mm column) or 0.9 mL/min (4 mm column); temperature 25–60 °C; pressure up to 25 MPa.
- Detection by direct conductivity; suppressor modules (MSM, MSM-HC, MSM-LC) enable organic solvent use up to 100%.
- Inline sample preparation techniques (MiPT, MiPCT, ultrafiltration, matrix elimination, dilution) for challenging matrices.
Used Instrumentation
- Metrohm ion chromatograph with high-pressure pump, conductivity detector and membrane suppressor.
- Smart iColumn housing with RFID chip storing column ID, start-up history and operating hours.
- Accessories: eluent degasser, pulsation absorber, inline filters and guard columns for baseline stability and extended column life.
Main Results and Discussion
Practical examples highlight performance characteristics:
- Baseline separation of Li+, Na+, NH4+, K+, Ca2+ and Mg2+ in under 6 minutes on a 4 mm×150 mm column.
- Temperature effects: elevated temperatures increase retention of polydivalent cations due to altered complexation kinetics.
- Flow rate variation balances analysis speed against resolution; higher flows shorten run times at the cost of peak separation.
- Organic modifiers (20–30% acetone or acetonitrile) reduce retention and background conductivity, enabling faster determinations.
- Eluent tuning through increased acid or ligand concentrations accelerates late-eluting transition metals and amines; 0.7 mmol/L dipicolinic acid optimizes divalent cation separation.
- Applications span trace lithium and borate analysis in nuclear power streams, fast tap water testing, alcoholic beverage stability studies, fertilizer and beer matrix profiling, and pharmaceutical amine determination.
Benefits and Practical Application of the Method
- Wide analyte scope – alkali metals, alkaline earth metals, amines and transition metals in a single run.
- High reproducibility and long column lifetime when using guard columns and proper filtration.
- Flexible method development via eluent chemistry, temperature control and organic modifiers.
- Low environmental impact due to aqueous eluents and minimal organic solvent consumption.
- Automation potential with integrated inline sample preparation modules.
Future Trends and Opportunities
Integration of ion chromatography with mass spectrometry will enhance selectivity and trace-level detection. Continued development of high-throughput columns and ultrafast gradients will meet increasing demands for rapid environmental and process monitoring. Advanced inline sample manipulation, such as desalting and on-column reactions, will broaden applications in biopharmaceuticals, metabolomics and nuclear safety. Smart diagnostics and data-driven maintenance of columns promise to reduce downtime and operating costs.
Conclusion
The Metrosep C4 column offers a highly adaptable solution for routine and specialized cation analysis across diverse matrices. Its robust performance, combined with flexible eluent and temperature control, ensures reliable separations from standard drinking water to complex industrial and biological streams. Proper installation, conditioning and guard column use secure reproducible results and long service life, while inline sample preparation and advanced detection options extend capabilities for trace and high-throughput applications.
Reference
- Metrohm AG. Metrosep C4 (6.1050.XX0) Manual, Document No. 8.107.8049EN, 2017.
- Metrohm AG. Analysis of Water Samples and Constituents with Metrohm Instruments, Monograph No. 8.038.5003.
- Metrohm Application Notes C-119 to C-171, Metrohm AG.
- Daellenbach, K. R.; Bozzetti, C.; et al. Characterization and source apportionment of organic aerosol using offline aerosol mass spectrometry. Atmospheric Environment, 2015.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Metrosep C 6 (Column manual)
2022|Metrohm|Manuals
Column manual Metrosep C 6 (6.1051.XX0 / 6.01051.XX0) Manual 8.107.8050EN / 2022-05-12 Metrohm AG CH-9100 Herisau Switzerland +41 71 353 85 85 [email protected] www.metrohm.com Column manual Metrosep C 6 (6.1051.XX0 / 6.01051.XX0) Manual 8.107.8050EN / 2022-05-12 Technical Communication Metrohm AG…
Key words
conductivity, conductivitycolumn, columnguard, guardeluent, eluentcations, cationsseparation, separationprevention, preventioncauses, causeslithium, lithiummagnesium, magnesiumsodium, sodiumcalcium, calciumammonium, ammoniumpotassium, potassiumdetermination
Metrosep C Supp 2 (Column manual)
2019|Metrohm|Manuals
Column manual Metrosep C Supp 2 (6.01053.XX0) Manual 8.0107.8007EN / 2019-06-24 Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com Column manual Metrosep C Supp 2 (6.01053.XX0) Manual 8.0107.8007EN /…
Key words
column, columnguard, guardmcs, mcsmsm, msmmagnesium, magnesiumeluent, eluentsequential, sequentialcalcium, calciumsuppression, suppressionlithium, lithiumseparation, separationpotassium, potassiumconductivity, conductivityprevention, preventionsodium
Metrohm: The column program
2021|Metrohm|Brochures and specifications
The column program The whole world of ion chromatography 2 Metrohm – the comprehensive solution 3 Metrohm has become a synonym for ion chromatography. For more than 30 years, Metrohm has been offering innovative and creative solutions in the area…
Key words
eluent, eluentcolumn, columnsodium, sodiumsubstrate, substratecarbonate, carbonatebody, bodymaximum, maximumpeek, peekmodifier, modifiernitrate, nitrateordering, orderingstandard, standardinformation, informationammonium, ammoniumdimensions
Metrosep C Supp 1 (Column manual)
2015|Metrohm|Manuals
Column manual Metrosep C Supp 1 (6.1052.4X0) Manual 8.107.8043EN / 2015-08-06 Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com Column manual Metrosep C Supp 1 (6.1052.4X0) Manual 8.107.8043EN /…
Key words
column, columnmcs, mcsmsm, msmguard, guardsequential, sequentialsuppression, suppressionseparation, separationconductivity, conductivityeluent, eluentprevention, preventioncauses, causesamines, aminesvariations, variationscations, cationsdirection