Metrosep C Supp 2 (Column manual)
Manuals | 2019 | MetrohmInstrumentation
Ion chromatography of cations, transition metals and amines with sequential chemical suppression provides high sensitivity (µg/L detection limits) and low baseline noise. It is vital for environmental monitoring, industrial quality control, pharmaceutical analysis and academic research.
This manual presents a complete workflow for the Metrosep C Supp 2 separation column: ordering details, technical specifications, column handling, eluent preparation, instrument start-up, method parameters, application examples and troubleshooting.
The Metrosep C Supp 2 column delivers high reproducibility, low detection limits, broad pH (0–12) and temperature stability (10–60 °C), compatibility with organic solvents and flexible method adaptation. Guard columns and inline filtration extend column life and protect against particulate or biological contamination.
Emerging directions include automated inline sample preparation, coupling with mass spectrometry, high-throughput gradient techniques, field-deployable miniaturized IC units, and development of universal suppressors and more robust stationary phases to broaden the scope of environmental and clinical analyses.
With proper column care, eluent management and adherence to recommended operating procedures, the Metrosep C Supp 2 system offers a robust, sensitive and versatile platform for routine and advanced cation analysis across diverse matrices.
Consumables, Ion chromatography, LC columns
IndustriesManufacturerMetrohm
Summary
Significance of the topic
Ion chromatography of cations, transition metals and amines with sequential chemical suppression provides high sensitivity (µg/L detection limits) and low baseline noise. It is vital for environmental monitoring, industrial quality control, pharmaceutical analysis and academic research.
Objectives and overview of the manual
This manual presents a complete workflow for the Metrosep C Supp 2 separation column: ordering details, technical specifications, column handling, eluent preparation, instrument start-up, method parameters, application examples and troubleshooting.
Methodology and instrumentation
- Stationary phase: 5 µm polystyrene/divinylbenzene copolymer with carboxyl groups, dimensions 100–250×4.0 mm.
- Guard column: Metrosep C Supp 2 Guard/4.0 recommended to protect the analytical column.
- Eluent: 5.0 mmol/L HNO₃ with 50 µg/L Rb as internal standard, degassed and filtered.
- Suppression: Sequential chemical suppression modules (MSM-HC C and MCS).
- Detector: Conductivity.
- Typical conditions: 1.0 mL/min flow rate, 40 °C column temperature, 20 µL injection loop.
- Chemicals: p.a. grade nitric acid (2 mol/L stock), RbNO₃, ultrapure water (≥18.2 MΩ·cm).
Main results and discussion
- Standard separation of Li, Na, NH₄, K, Mg and Ca with baseline noise <0.1 nS/cm.
- Temperature effect: higher temperatures accelerate retention times, with non-uniform shifts for K and Rb.
- Flow rate effect: linear decrease in retention times with higher flow.
- Eluent strength: increasing HNO₃ disproportionally accelerates polyvalent cations, potential co-elution at high concentration.
- Organic modifiers (up to 20% acetone or acetonitrile) reduce retention times but may broaden peaks.
- Applications include µg/L trace analysis, non-suppressed detection, separation of cations in the presence of transition metals, dose-in gradient methods, rapid four-cation screening in <5 min and amine determination.
Benefits and practical applications
The Metrosep C Supp 2 column delivers high reproducibility, low detection limits, broad pH (0–12) and temperature stability (10–60 °C), compatibility with organic solvents and flexible method adaptation. Guard columns and inline filtration extend column life and protect against particulate or biological contamination.
Future trends and potential uses
Emerging directions include automated inline sample preparation, coupling with mass spectrometry, high-throughput gradient techniques, field-deployable miniaturized IC units, and development of universal suppressors and more robust stationary phases to broaden the scope of environmental and clinical analyses.
Conclusion
With proper column care, eluent management and adherence to recommended operating procedures, the Metrosep C Supp 2 system offers a robust, sensitive and versatile platform for routine and advanced cation analysis across diverse matrices.
References
- Brochure: Cation suppression in ion chromatography – Cation determination in the trace range (Metrohm AG).
- Application Notes CS-016 to CS-020, Metrohm AG.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Metrosep C Supp 1 (Column manual)
2015|Metrohm|Manuals
Column manual Metrosep C Supp 1 (6.1052.4X0) Manual 8.107.8043EN / 2015-08-06 Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com Column manual Metrosep C Supp 1 (6.1052.4X0) Manual 8.107.8043EN /…
Key words
column, columnmcs, mcsmsm, msmguard, guardsequential, sequentialsuppression, suppressionseparation, separationconductivity, conductivityeluent, eluentprevention, preventioncauses, causesamines, aminesvariations, variationscations, cationsdirection
Metrosep C 6 (Column manual)
2022|Metrohm|Manuals
Column manual Metrosep C 6 (6.1051.XX0 / 6.01051.XX0) Manual 8.107.8050EN / 2022-05-12 Metrohm AG CH-9100 Herisau Switzerland +41 71 353 85 85 [email protected] www.metrohm.com Column manual Metrosep C 6 (6.1051.XX0 / 6.01051.XX0) Manual 8.107.8050EN / 2022-05-12 Technical Communication Metrohm AG…
Key words
conductivity, conductivitycolumn, columnguard, guardeluent, eluentcations, cationsseparation, separationprevention, preventioncauses, causeslithium, lithiumsodium, sodiummagnesium, magnesiumcalcium, calciumammonium, ammoniumpotassium, potassiumdetermination
Metrosep C 4 (Column manual)
2017|Metrohm|Manuals
Column manual Metrosep C 4 (6.1050.XX0) Manual 8.107.8049EN / 2017-08-28 Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com Column manual Metrosep C 4 (6.1050.XX0) Manual 8.107.8049EN / 2017-08-28 zst…
Key words
column, columnconductivity, conductivityguard, guardseparation, separationlithium, lithiummagnesium, magnesiumeluent, eluentcalcium, calciumprevention, preventionpotassium, potassiumcauses, causessodium, sodiumammonium, ammoniumcations, cationsnotice
Metrohm: The column program
2021|Metrohm|Brochures and specifications
The column program The whole world of ion chromatography 2 Metrohm – the comprehensive solution 3 Metrohm has become a synonym for ion chromatography. For more than 30 years, Metrohm has been offering innovative and creative solutions in the area…
Key words
eluent, eluentcolumn, columnsodium, sodiumsubstrate, substratecarbonate, carbonatebody, bodymaximum, maximumpeek, peekmodifier, modifiernitrate, nitratestandard, standardinformation, informationordering, orderingammonium, ammoniumdimensions